HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND I PATIO <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA SOA 2-3.1 L <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET r <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5714 EDITION DINING <br />(2014) MECHANICAL CODE 603.1 ROOM 8• S/A LIVING <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE FROM ROOM <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE ABOVE <br />SECTION 403. <br />BEDROOM #2 <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE I <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />4 12X8 <br />ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIB/SMOKE <br />----- <br />I I I� - - - - - --------- l <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH I ------- <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10, GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. LIXKITCHEN <br />12XI2 14AXS911. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. THR1 BATH #2 <br />FANTECN DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS.X Ii l l l i l9TORNOTE- <br />ALL HVAC TO HAVE PROPER O PANS W/ DRAINS PAN. r -1 <br />ATTIC o <br />CEILING - - L _---�— - -_ - -_ <br />EXTERIOR WALL <br />O O 12XB—� -- 8X4 <br />AIR RETURN <br />PLENUM T y �' \ <br />SUCTION AND LIQUID -� ( �� \\ p <br />AIR SUPPLY �1 REFRIGERANT LINES I (ABOVE <br />AIR HANDLER <br />-� EXTERIOR WALL <br />1 3/4' PVC CONDENSATE DRAIN LINE FLEX I - <br />EVAP. TRAY � 1 PVC SLEEVE TO LINES BELOW SLAB 1 FOYER <br />_ I <br />T REFRIGERANT LINES TO I <br />PLATFORM- RETURN CONDENSING UNIT <br />__ TRAP DRAIN LINE AND TERMINATE -1 GARAGE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (2014) ! <br />MECHANICAL BLDG. CODE ! <br />SECTION 3012.1.1 PORCH <br />HVAC DRAINS <br />FIRST FLOOR MECHANICAL PLAN <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />_ —'-- FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK J I P.V.0 OPT[/SPEC <br />-��-- --- - v kINV. SEE <br />-9 SITE PLAN <br />FLOOR SLAB CLEAN —OUT (TYP. <br />NT <br />COUNTERSUNK <br />G.O. PLUG <br />16 <br />SEE SPEC. <br />—r--------- <br />\l\\ � .-_ _ `- J� I-B•XB• GONG. <br />FIN. GRADE' 'k <br />OR PAVING - - <br />_ FITTING OR <br />I EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I I <br />% INV. SEE <br />NEXT. GROUND CLEAN —OUT (TYPNT <br />SECURE STRAP TO CONC. <br />CONDENSER <br />W/ (2)-3/'X2' TAPCONS <br />UNIT T <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB <br />SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER <br />UNIT <br />CONNECTION <br />TO PAD <br />NOTE: MAIN OND. DRAIN 3/4' DIA. <br />OVER HEAD 0 12' FROM STRUCTURE <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE= SUPPLY TRUNK <br />- <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBO <br />O <br />CEILING EXHAUST FAN <br />Fl <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />QT <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />L441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-774-4078 <br />www.abdesigngmp.com <br />kh AA #: 0003325 <br />w <br />w <br />0 <br />a <br />0 <br />F <br />0 <br />SVSDIV ffi LOT: <br />SILVERADO <br />LOT #24 <br />BLK #1 <br />PROJECT# <br />04128.000-24001 <br />MCDA c <br />4EHB <br />"2605—HAYDEN" <br />GARAGM B'WMG: <br />RIGHT <br />PAGE: <br />FIRST <br />FLOOR <br />MECHANICAL <br />PLAN <br />50 MPH EXP. B <br />ARCHITECT <br />STATE OF FL ORDA <br />d <br />PRINT <br />DAT3M 11/2/16 <br />SCALE: 1 /4"= l' — O" <br />SiIffiET <br />10 <br />