A p C N I T E C T 8 <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(W AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM, 2. SIDES. 3. TOP <br />I. <br />X.' VENT CAP 15 TO BE SET IN BED <br />- <br />X- OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 15 TO BE <br />TOOLED 50 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />".. <br />X E-Z BEAD ALL AROUND <br />��..,.> <br />VENT -APPLY SEALANT ALL <br />i ; <br />X JOINTS AND INTERSECTIONS <br />' <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />— <br />- - <br />ON ALL SIDES, Ya' CAULKING B JOINT <br />ALL AROUND <br />PER FBC R703.6.01 —j <br />Exterior lathing and plastering <br />BACKER ROD <br />Exterior use of pordand cement plaster <br />-- <br />shall comply with the application <br />i <br />X <br />requirements of ASTM C 926-11 A. <br />'X <br />X <br />instaliation of exterior lathing and framing <br />I shall comply with ASTM C 1063-11A. <br />WRB LAYER "I, <br />il.. <br />X, <br />STUCCO WRAP <br />I1 <br />. HOODED VENT <br />X <br />X 9' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER •2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT ( FRAME) <br />OOD SHEATHING <br />LAYER <br />STUCCO WRAP <br />LAYER �2, _RTIFIBER <br />f��Zl <br />APER <br />wooDCONstucT <br />`METAL LATH <br />a' CM VINYL CASING BEAD <br />W RA15ED BAND <br />Ye' TO %' MID -WALL <br />WEEP SCREED <br />&' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK) <br />'I- o u_ - <br />DRAINAGE PLANE (WRB <br />LAYER "I, STUCCO WRAP) <br />L1R5 LAYER #2 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO C <br />WOOD SHEATHING ['ZZ_�%2 <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER FBG <br />R'103.6.1 / ASTM C-84l-12, MIN. 2.5 LBS, <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINIS" <br />lo' SELF ADHESIVE <br />OVER TOP 8 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUR DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT m <br />TOP d SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE - <br />FLASHING (INSTALL <br />PER MANUR SPEC5.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />ELEG. METEF <br />VERIFY LO <br />r — — — <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />/AICCH I V ICGC�CIYC <br />STUCCO SCRATCH COAT <br />d 1 COAT OF PAINT W/BAGK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />ELEG. METER FIELD <br />VERIFY LOCATION <br />- I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOGYANOTE-POLYBLEND FOAM <br />�"^ "� ' ')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />g' THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO %' MID -WALL <br />WEEP SCREED <br />—6' SELF-ADHESIVE <br />FLASHING <br />'J�WOOD FRAMED <br />WALL <br />ONTAL HORIZWEEP SCREED <br />( FRAME TO FRAME) <br />:O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOU5EWRAP <br />BELOW <br />CUT SUCH THAT - <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z <br />OVER 60 M <br />GRADE V' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />LAYER -1, <br />STUCCO WRAP <br />B WRLAYER -2, FORTMOER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1/8, TEXTURED <br />CON5TRJCTION l�FINISH • WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.C. MAX <br />a' C-Mu <br />X' TO%' MID -WALL <br />G WEEP 5REED <br />• W WIDE STRIP SELF <br />— ADHESIVE FLASHING. CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />a' <br />WRB LAYER •I, <br />STUCCO WRAP <br />CUT 'X' INTO 7 <br />SELF -ADHERING lX1 <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />APPLY 60 MIN - <br />GRADE "D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />STEP #2 <br />WRB LAYER "I, <br />STUCCO WRAP <br />ElSELF -ADHERING <br />MEMBRANE FLASHING <br />'­ WRB LAYER °2, FORTIF15ER <br />BUILDING PAPER <br />STEP #4. <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #ram STEP #� <br />OELECTRICAL RECEPTACLE <br />.t-. LONGWOOD, FL 32750� V <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />y <br />w <br />U <br />0 <br />a <br />V <br />0 <br />A <br />ti <br />F <br />ee i oz� <br />RADO <br />#17 <br />#1 <br />#t <br />04128.000-17001 <br />MODELS <br />4EHB <br />"2605- HAYDEN" <br />GARAGE EIVWG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />00 ARCHITECT <br />DATM 11/09/16 <br />BCAZ.= 1/4"=1'-0" <br />S <br />WA2 <br />