My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36161 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36161 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:34:45 AM
Creation date
2/19/2025 12:07:59 PM
Metadata
Fields
Template:
Building Plans
Street #
36161
Location
Stable Wilk Ave
Contractor
DR Horton
Building Plans - Permit #
18369
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT 5Y5TEM5 INSTALLED IN NON -CONDITIONED AREAS 514ALL. BE CONSTRUCTED OF A VALUE <br />OF NO LE55 THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBCR 57H EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS A5 PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORI"IS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -GUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />�- <br />0� <br />EXTERIOR WALL <br />PLENUM <br />- <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />I <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETU�I <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (2014) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.1.1 <br />HVAC <br />DRAINS <br />5CORIATED NICKEL <br />BRONZE FL. PL. <br />BRASS PLUG <br />INSI <br />CAUL <br />FIN. FLOOR <br />OR WALL <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />DE I 1SERIES NICKEL BRASS TOP <br />K � I P.V.0 OPTI/SPEC <br />i — III — i <br />----- — I� ITE PLAN <br />SITE PLAN <br />OFLOOR SLAB CLEAN —OUT (TYPNT)5 <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />--- <br />BROKEN LINE= RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />FMCEILING <br />EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO GONG CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB '8X1 1/4' 5HT. MTL. SCREWS <br />/ <br />CONDENSER UNIT <br />L <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />C.O. PLUG <br />1' 6' <br />SEE SPEC. <br />m <br />_ <br />FIN. GRADE _ <br />_E <br />OR PAVING— <br />FITTING OR <br />I <br />EXTENSION TO SOIL <br />— OR WASTE AS <br />I <br />REQUIRED <br />I <br />— --_� <br />-- —_VINV. SEE <br />SITE PLAN <br />NEXT. GROUND <br />CLEAN —OUT (TYPN) <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C R I T E C T S <br />6 <br />Design <br />Grou .nam <br />41 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />W <br />x <br />h <br />c�> <br />w <br />0 <br />c, <br />w <br />w <br />c <br />IN <br />Bumm Ae LOT. <br />SILVERADO <br />LOT #23 <br />BLK #1 <br />PROJEC <br />04128.00 -23001 <br />uoDEu <br />4EBB <br />1828- CALI" <br />GARAGE S'WMG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />ARCHfTECT <br />STATE OF FLONDA <br />J <br />P � D11/3/16 <br />BCALE: 1 /4"=1'— 0" <br />BiIEET <br />