My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36185 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36185 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:46:17 AM
Creation date
2/19/2025 12:06:59 PM
Metadata
Fields
Template:
Building Plans
Street #
36185
Location
Stable Wilk Ave
Contractor
DR Horton
Building Plans - Permit #
18370
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING:, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SH4i LsL. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB t MASTIC. AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA 90A 2-3.1 <br />4, FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOT <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING^ <br />^� <br /><> <br />EXTERIOR WALL <br />PLENUM <br />L <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />1 J <br />REFRIGERANT LINES <br />i� <br />1 <br />AIR HANDLER <br />EXTERIOR WALL <br />J <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />�� y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING, UNIT <br />�`---- <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (2014) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.1.1 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. — � OR WALL <br />BRASS PLUG <br />_-- <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />— <br />REQUIRED <br />I <br />WADE 8240-K JOSAM 56000 <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />CAULK J <br />I <br />P-VC— OPTI/SPEC <br />y <br />< <br />SEE <br />--ut--'---,--.y <br />J,INV. <br />1SlTE PLAN <br />FLOOR SLAB CLEAN —OUT (TYP.) <br />NTS <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE= SUPPLY TRUNK <br />-- <br />BROKEN LINE= RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN t LIGHT <br />CIA <br />OUTSIDE AIR <br />Q <br />THERMOSTAT <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />•SXI 1/4' SHT. MTL, SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD o 12' FROM STRUCTURE <br />COUNTERSUNK <br />G.O. PLUG <br />16 <br />— SEE SPEC. <br />--------- <br />R\\ '- — -,— I'-8'XS' CONC. <br />FIN. GRADEOR PAVING — <br />FITTING OR <br />I I EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I I <br />y <br />-�Iw------J„--_V INv.SEE <br />STET PANL <br />NEXT. GROUND CLEAN —OUT (TYPN ) <br />L, <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C II I T E C T S <br />6 <br />Design .ign <br />Gr <br />41 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abde igngmup.com <br />AA #: 0003325 <br />w <br />a <br />2 <br />c, <br />ti <br />0 <br />4 <br />F <br />V <br />Z <br />m <br />oulm V. a. I.OT: <br />SILVERADO <br />LOT 21 <br />LOT 1 <br />PROJECT <br />04128.07-21001 <br />MODEM <br />4EBB <br />"1828-CALI" <br />GARAGE 911INC: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%150 MPH EXP- B <br />od <br />ARCHrrECT <br />IDA=: 11 /02 /16 <br />SCALE: 1 /4"= V - 0" <br />SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.