My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38247 Sonnet Landing Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38247 Sonnet Landing Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:32:13 PM
Creation date
2/19/2025 11:34:49 AM
Metadata
Fields
Template:
Building Plans
Street #
38247
Location
Sonnet Landing Ave
Contractor
DR Horton
Building Plans - Permit #
2817
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL b' SELF -ADHERING <br />MEMBRANE FLASHING OVER STUCCO <br />TOP, SIDE(W AND BOTTOM FINISH FLANGES OF NON-MOVABLEFRAME _ <br />THE EXHAUS. 6' SELF ADHESIVE <br />SEMENOF FLASHING TO BE, OVER TOP 4 SIDES WOOD CONSTRUCTION <br />CCE <br />I. BOTTOM, 2. SIDES, 3. TOP <br />,x' VENT CAP IS TO BE SET IN BED SELF WOOD SHEATHING <br />I..;I • OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE FLASHING ' WRB LAYER •I, <br />TOOLED 60 AS TO DEFLECT UNIT <br />i WATER AWAY FROM JOINTS. STUCCO WRAP 1441 N. RONALD REAGAN BLVD <br />VPRJ=-MANUF:. DRYER LONGWOOD,FL32750 <br />E-Z BEAD ALL AROUND_ <br />VENT -APPLY SEALANT ALL VENT CAP (SET IN WRB LAYER r'2, FORTIFIBER FAx:ao777 -607a <br />1 78 <br />JOINTS AND INTERSECTIONS CONT. SEALANT) BUILDING PAPER www.X:407 7744 78 ..�;. APPLY SEALANT AT PERIMETER OF .a B: O003325 <br />BACKER ROD NON -MOVABLE FRAME AND STUCCO <br />AA y' • <br />ON ALL SIDiDES, +CAULKING JOINT <br />ALL <br />SEALANT • <br />TOP 1 SIDES <br />THICK, 3 COAT CEMENT <br />WOOD SHEATHING <br />PER SECTION R703.7 <br />PLASTER <br />LAYER 9, <br />Exterior hMna and plastering <br />STUCCO WRAP <br />BACKER ROD Exterior use of portland cement plaster <br />shall comply with the application <br />DRYER VENT (BLOCK) <br />Ya' TO Y*' MID -WALL <br />LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />requirements of ASTM C 926-18b. <br />X.. <br />6 B <br />WEEP SCREED <br />METAL LATH <br />Installation of exterior lathing and framing <br />WOO�STZ1GT1d� Y�1wPNITE14 D <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />6' SELF-ADHESIVE <br />FASTEN TO WOOD STRUCTURAL <br />1 <br />STU h :.x. <br />FLASHING <br />MEMBER • Or -Max <br />e' cru f <br />STUCCO WRRAP HOODED VENT <br />BUILDING PAPER <br />WOOD FRAMED <br />K' TO ' <br />3 COAT CEMENT <br />OVERQUICK <br />FLASH' — — — <br />' ' WALL <br />pTWI TER <br />METAL LATH <br />HORIZONTAL <br />WEEP SCREED <br />• ''G <br />(FRAME TO FRAME Z <br />WRB LAYER 9, FORTIFIBER <br />BUILDING PAPER <br />PIPE THROUGH / <br />WALL <br />,; 6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />WOOD SHEATHING <br />I <br />\�MASOPilY <br />OEFORE APPLYING <br />TTl XTTT TTT lTM ITT A l (T\ <br />`L. TEXTURED <br />WOOD SHEATHING <br />FLASHING <br />[ <br />'J ' <br />pVERM BOXE <br />ANp O R <br />6' WIDE STRIP SELF <br />APPROVED WR8 <br />ADHESIVE FLASHING, CLEAN <br />LAYER n <br />MASONRY DEFORE APPLYING <br />STE 01 <br />STE <br />Z RLAeHe1G <br />ELEC. METER FIELD <br />I <br />VERIFY LOCATION <br />ELEC. METER FIELD <br />APPROVED <br />e7CHE VENEER <br />OVER SCRATCH COAT <br />VERIFY LOCATION <br />HOUSEWRAP <br />BELOW <br />WRB LAYER 01, <br />STUCCO WRAP <br />HORIZONTAL WEEP SCREED <br />1 114. <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (I) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />CUT SUCH THAT <br />No MEMBRANE <br />ENTERS BOX, <br />9 <br />APPLY bm MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />W/STONE VENEER <br />METER <br />APPLY TO FACE <br />SELF -ADHERING <br />(FRAME TO BLO C K� <br />EDGE <br />FLASHING OVER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />'°'PROVED <br />HOUSEWRAP <br />LEGEND <br />ISOCYANOTE-POLYBLEND FOAM <br />WRB LAYER n, FORTIFIBER <br />!'GREAT STUFF' OR SIMILAR) <br />BUILDING PAPER <br />APPLY A SILICON <br />STEP *3 <br />STEP <br />#� <br />DRAINAGE PLANE (WRB <br />BASE SEALANT AT POINT <br />LAYER 01 STUCCO WRAP)1�4THAT <br />ELEC WIRE PENETRATES <br />IstiMDiV. ae L,O'h <br />ABBOTT PARK <br />LOT #17 <br />BLK. #9 <br />PROJECT# <br />04181.000-17091 <br />MODELA <br />3EEB <br />"2260—ELSTON" <br />GARAGE IB11WG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />60 MPH <br />UJRB LAYER 02 (FORTIFIBER - - - - - <br />COATI OVER <br />BUILDINGS PAPER) <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />APPLY E-2 BEAD_o.o.e <br />STUCCO/ CV. FINISH <br />$EEEP)1GAL WALL <br />METAL LATH x—x—x—x <br />t 1 COAT OF PAINT W/BACK- <br />OVER 60 MIN <br />ROLL PRIOR TO <br />GRADE 'D' <br />FELT-PROVIDE <br />IDE <br />; <br />METAL LATH E' <br />o uwm <br />STUCCO <br />ELEC. METER INSTALLATION PROVIDE STUCCO SCRATCH <br />SEALANT <br />;e oo <br />�1 <br />WOOD OR 1/16' ZIP WALL <br />COAT LAR63ER THAN THE EC <br />JOINTS AND <br />INTERSECTIONS <br />a °< <br />o• o• o 0 0 <br />® <br />METER CAN OR METER CAN <br />SHEATHING <br />COMBO OR METER CAN AND <br />�� <br />SELF-ADHESIVE FLASHING - - - - - <br />DISCONNECT <br />DATs 05/24/21 <br />METAL LATH: LATH TO BE PER SECTION <br />OQ ELECTRICAL CONDUIT <br />STEP #5 <br />STEP #�o <br />SCALE:1/4"=1'-0" <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />U PENETRATION <br />°SET <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />O ELECTRICAL <br />9 <br />RECEPTACLE <br />A� <br />