Laserfiche WebLink
DBL. TOP PLATE <br />CONT. <br />6Z <br />LAPTOP PLATE A MIN. OF 48" <br />AND NAIL W/ 16d COMMON <br />Zx HEADER SEE PLAN FOR SIZE <br />NAILS, 2-ROWS, 4" O.C. BTM. <br />Q <br />AND QUANTITY PROVIDE 1x <br />IS BLOCKING FOR SHUTTER <br />LAP TO OCCUR OVER STUD <br />WOOD OR 1/7' PLYWOOD <br />INSTALLATION. PROVIDE 12" <br />FILLER(S). NAIL ALL TOGETHER <br />PLYWOOD FILLER(S). NAIL <br />W/ 16d COMMON NAILS, <br />q <br />ALL TOGETHER W/ 16d <br />b <br />2-ROWS, 6' O.C. <br />COMMON NAILS, 2-ROWS, 6' <br />O.0 <br />SHORT 2x STUDS <br />BETWEEN HEADER ABOVE AND <br />® <br />FRAMING DIRECTLY ABOVE <br />(1) 2x8 FLAT TOE NAILED TO <br />3W DIA. x 8" MIN. EXPANSION <br />WINDOW <br />JACK STUD I NAILED INTO <br />BOLT W/3x3OVERSIZED <br />INSIDE AND OUTSIDE PLY OF <br />WASHERS PLACED 16' O.C. 4" <br />MIN. CONC. EMBEDMENT <br />SECTION A <br />FILLER BELOW W/ <br />-A <br />R40 <br />' <br />COMMON NAILS, 6' O. O.C. <br />I <br />® SHORT 2x STUDS <br />BENEATH WINDOW SILLS 2.6 BLOCKING FOR SHUTTER <br />INSTALLATION. PROVIDE 1/7' <br />PLYWOOD FILLER($). NAIL <br />2x MID -HEIGHT BLOCKING b ALL TOGETHER W/ 16d <br />AND ANY PLYWOOD SEAMS COMMON NAILS, 2-ROWS, 6" <br />W/ (2)16d TOE -NAILS, EACH 2x HEADER SEE PLAN FOR O.C. <br />END 4 u SIZE AND QUANITY <br />PROVIDE Ix WOOD FILLER(S). <br />NAILS ALL TOGETHER W/ 16d SINGLE BTM. PT PLATE <br />COMMON NAILS, 2-ROWS, 6" <br />SIMPSON H1OA W/ iOd x 1 12" O.C. <br />GALV. COMMON NAILS, FILL SIMPSON SPH4 OR SPH6 <br />ALL HOLES OR SPHB TOP &BOTTOM <br />4'-0-MIN, TOP PLATE SPLICE STUD PLATE TIES W/ IOd x 1 <br />AND NAIL WI 16d COMMON 1/2" GALV. COMMON NAILS <br />NAILS, 2-ROWS, 4" O.C. (AT EACH STUD) FILL <br />EVERY HOLE. DO NOT USE T ' <br />3" LONG NAILS <br />e ' BTM. MEMBER OF TOP — I <br />—Hq JI PLATE SPLICE MUST LSTA18 WI l0dx3" GALV. COMMON <br />OCCUR OVER STUD. NAILS, (7) EACH END TOTAL OF 14 <br />4" NAILS. APPLIED TO INSIDE FACE (1) 1 FLAT TOE NAILED TO <br />TY, <br />. ONLY FL#17244 _ JACK STUDS <br />EE SCHED <br />OR # STUDS <br />UNDER <br />HEADER <br />SEE SCHED - <br />FOR # FULL <br />HEIGHT <br />2x STUDS <br />4" 1O <br />TYP. <br />I <br />4" 3X3 OVERSIZED WASHERS PLACED <br />TYP. �f"�F 37' O/C 6' MIN CONOEMSED. TYP. <br />16'MAX. <br />PROVIDE (3) STUDS <br />CORNERS LAP TOP <br />PLATE MEMBERS <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALIJFLOOR SHEATHING <br />FASTENER SCHEDULE" <br />C1 <br />2x MID -HEIGHT BLOCKING <br />AND ANY PLYWOOD SEAMS <br />W/ (2) 16d NAILS EACH END <br />16' MAX. <br />(3)112 HEADER PROVIDE DBL. TOP PLATE <br />1/Z' PLYWOOD FILLER($). NAIL <br />ALL TOGETHER Wl 16d CONT. <br />COMMON NAILS, 2-ROWS, 6' — — <br />O.0 <br />2078 2x1W6 bft <br />(5) 1 STUDS IN CORNER. NAIL <br />THE (3) CORNER STUDS <br />TOGETHER W/ 16d NAILS, S' <br />O.C. <br />LAP TOP PLATES <br />AT CORNER, <br />(4) 1 STUDS IN CORNER. NAIL <br />THE (3) CORNER STUDS <br />TOGETHER W/ 16d NAILS, 3" <br />O.C. <br />NUMBER OF HEADER STUD SUPPORTING HEADER ON EACH SIDE <br />NUMBER OF KING STUDS <br />EACH END OF HEADER <br />SPAN <br />HEADER SIZE <br />(2)2x6 <br />(3)2x6 <br />(2)2xNIX4121II4 <br />(3) IS)2x10 <br />(3)2x10 <br />(2)2x12 <br />(3)2x12 <br />STIR 8PA0N0o18'0.0. <br />gND> ACN002P0.0. <br />0-2ft <br />a <br />N <br />O <br />a <br />2 2x4 <br />2 2x4 <br />2 2x(3) <br />14 <br />SPAN <br />KINGS <br />SPAN <br />KINGS <br />2x6 <br />(2)2x6 <br />()) <br />(2)2x6 <br />(2) 6 <br />(3) <br />3-4ft <br />0 - 2ft <br />3-4h <br />1 <br />2 <br />0 - 2ft <br />3-41 <br />1 <br />2 <br />Dc4 <br />2.4 <br />2 2x2 <br />2x4 <br />3) 2x4 <br />() 4 <br />16 <br />2x2)IS <br />(2)2x6 <br />()2x6 <br />(2) <br />5- 8ft <br />2x4 <br />2x4 <br />2x2 <br />2x4 <br />2 2x4 <br />2 2x4 <br />2 2x4 <br />5- 6 h <br />3 <br />5- 6 ft <br />2 <br />(7.8ft <br />3 <br />7-8ft7-8ft <br />2x4 <br />2x4 <br />2x2 <br />2x4 <br />2 2x4 <br />2 2x4 <br />2 2x4 <br />90ft5B-10h3 <br />(2)2x6 <br />9-10ft <br />2x4 <br />2x4 <br />2X2 <br />2x4 <br />2 2x4 <br />(2)2.4 <br />2 2x4 <br />10 -12 ft <br />5 <br />10 -12 ft <br />4 <br />2x6 <br />DB <br />2x6 <br />2z <br />2x6 <br />2x6 <br />2x6 <br />10 - 12 ft <br />14 <br />2x4 <br />14 <br />1414 <br />2 2x4 <br />2 2x4 <br />2 2x4 <br />1 IS <br />IS <br />TYPICAL EXTERIOR WOOD FRAME <br />0 WALL CONSTRUCTION DETAIL <br />SCALE: 3/4"=V-0" <br />NAIL STUDS NAIL s I UUS <br />TOGETHER W/ TOGETHER Wl <br />12d 0 12'O.C. 12d ® 1Z'O.C. <br />PROVIDE (3) STUDS PLYWOOD SHEATHING, <br />CORNERS LAP TOP SEE"ROOFANALL/FLOOR <br />PLATE MEMBERS SHEATHING FASTENER <br />SCHEDULE" <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALL/FLOOR SHEATHING <br />FASTENER SCHEDULE" <br />C2 J�9_ If <br />EXTERIOR /WOOD <br />PLACE 30# ROOF FELT BEHIND SCALE: 1 1/T=1'-0" <br />VERT. STUDS SO AS TO <br />SEPARATE WOOD AND <br />MASONRY/ CONCRETE(TYP.) <br />12" DIA. SIMPSON TITEN <br />BOLTS 5" MINIMUM <br />EMBEDMENT INTO GROUTED <br />CELL, 8" FROM ENDS AND <br />16' O/C, VERTICALLY MAX <br />NAIL STUDS <br />TOGETHER W/ <br />12d ® 17' O.C. <br />SHEATHING ON <br />NTERIOR OR <br />B IEXTERIOR OF <br />WOOD WALL <br />(2) 1 TO BLOCK ON 2x8 & 2x8 WALL <br />1Q" DIA. SIMPSON <br />TITEN BOLTS 5" MINIMUM <br />EMBEDMENT INTO GROUTED <br />CELL, 4" FROM ENDS AND <br />16" O/C, VERTICALLY MAX 117 <br />16' MAX. <br />PROVIDE (3) STUDS C <br />CORNERS LAP TOP <br />PLATE MEMBERS <br />16" MAX. <br />D PROVIDE (3) STUDS 0 J <br />CORNERS LAP TOP <br />PLATE MEMBERS <br />NAIL STUDS J U N <br />TOGETHER W/ <br />12d012- O.C. <br />PLYWOOD SHEATHING, SEE <br />"ROOFNVALUFLOOR SHEATHING <br />FASTENER SCHEDULE" <br />C3 <br />A <br />(1) ITO BLOCK ON 14 WALL PLACE 30# ROOF FELT <br />(2) 2x TO BLOCK ON IS & 18 WALL BEHIND VERT. STUDS SO AS <br />TO SEPARATE WOOD AND <br />MASONRY/ CONCRETE(TYP.) <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD,FL32760 <br />PH: 407-774-6078 <br />FAX: 407-774 4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />91# <br />C <br />dR <br />a <br />r <br />W <br />z <br />O <br />