38279 Sonnet Landing Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38279 Sonnet Landing Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:43:05 PM
Creation date
2/19/2025 11:10:29 AM
Metadata
Fields
Template:
Building Plans
Street #
38279
Location
Sonnet Landing Ave
Contractor
DR Horton
Building Plans - Permit #
2758
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL W SELF-ADHERINGPLA6WM OVER STUCCO <br />To�P, r>E(E(6) Oott FINISH <br />PLANam OF NON -MOVABLE <br />FRAME OF TM EXNAIXT. 6' SELF ADHESIVE WOOD CONSTRUCTION <br />AEQLr►4'r OF FLASHING TO EE. OVER TOP 4 SIDES rl_� <br />L OKMOM. 2. SIDES, 9. TOP <br />K= VENT CAP IS TO BE GET IN BED SELFOr SEALANT WOOD SHEATHING-1 <br />' SIDES ONLY. ASEALLA M18 TO eE UNI�I ' low WRB LAYER el, <br />TOOLED GO AS TO DEFLECT STUCCO WRAP <br />: WATER AWAY FROM JOINTS. 1441 N. RONALD REAGAN GLVD. <br />'X• E-Z BEAD ALL AROUND PREMANUR DRYER LONGWOOD, FL32750 <br />A VENT -APPLY SEALANT ALL VENT CAP (SET IN UM LAYER 1'2, FORTIFIBER FAX: 4oi74 7 -607 8 <br />r JOINTS AND INTERSECTIONS CONT. SEALANT) <br />DAdCEI¢ IUD 1 NON -MO -A AT PERIMETERRAME AND O 5UILDINCx PAPER www.abdesigngroup.com <br />AA N: 0003326 <br />ON ALL GI y4 CAULKING JOINT SEALANT <br />I I ALL A�� TOP 4 SIDES �' THICK 3 COAT CEMENT WOOD SWATWNG <br />I I PER SEG 1 N —� PLASTER LAYER 01, <br />I I EXw" Ntlllno and 01n1IfMm STUCCO WRAP <br />I I Exterior use of portland cement plaster 4 LAYER , FORTIPMER <br />BACKER ROD shall comply with the application 6 B DRYER VENT (BLOCK) Ys' TO K' MID -WALL i6ILDI.IG PAPER <br />requirements of ASTM C 926.18b. 1iWEEP SCREED METAL LATH <br />' Installation of exterior lathing and framing Uk= <br />i shall comply with ASTM C 1063-19a, 0"TPIIGTIDIJ <br />or ASTM 1787. bo' SELF-ADHESIVE FASTEN TO °boo STRicfuw- <br />WRIMCMDER • T' OG. MAX <br />STd LATER ILFLASHIW_% a' CMSTUCCO WRAP HOODED VENT BUILDING PAPER <br />OVER 'QUICK WOOD FRAMED Sects <br />I' THICK, 3 COAT CEMENT FLAG►+ r — — — —I WALL <br />PLASTER _ :' = �$ <br />L <br />METAL LATH _ , HORIZONTAL WEEP SCREED <br />UPS LAYER n, FOR IRIDER PIPE T" WALL ( FRAME TO FRAME .' won STRIP AeLF <br />BUILDING PAPER <br />ADNESNE FLASNRJG, CLEAN <br />WOOD "ATHNG i\ MASONRY NW40M APPLYING <br />TTl tr"Tl T7'T LT rr1 / T:1 Yl A l LT1% YK TEXTUED <br />lb <br />am <br />Li <br />WOOD SHEATHING <br />MEMBRANE FLASHING? <br />OVER BOX AND OVER <br />6' AIDE STRIP SELF <br />APPROVED WRI5 <br />ADHESIVE K ASFING, CLEAN <br />h1A80N4 PJ0OIEAPPLYING <br />I <br />STEF 01 <br />LAYER h <br />STEP #2 <br />: FLAaF1ING <br />� <br />ELEC. METER FIEL <br />1 <br />STC vWw" <br />E <br />VERIFY LOCATION <br />ELEC. METER FIELD <br />A.PPR <br />ovt_rR SCRATCH CHAT <br />VERIFY LOCATION <br />PD <br />BELOW <br />- WRS LAYER 01 <br />STUCCO WRAP <br />HORIZONTAL WEEP SCREED <br />7 <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />�T +THAT <br />NO MEMRANE <br />0 <br />= <br />APPLY 60 MIN- <br />GRADE D FELT <br />MEMBRANE FLASHNG <br />S R <br />10 TO I NST I G. PRIOR ALL NG ELEC. <br />ENTERS Bo x, <br />OVER <br />METER <br />APPLY TO FACE <br />?s <br />SELF -ADHERING <br />FRAME TO BLOCKI <br />EDGE <br />FLASHING OVER <br />CAVITY TO BE FILLED <br />APROVEP <br />WOUSEUIRAP <br />WITH RIGID POLYMERIC <br />LEGEND <br />ISOCYANOTE-POLYBLEND FOAM <br />WRB LAYER n, FORTIFIBER <br />('GREAT STUFF' OR SIMILAR) <br />BUILDING PAPER <br />APPLY A SILICON <br />J' TEP 03 <br />5T <br />DRAINAGE PLANE (WRB <br />5ASE SEAANT AT POINT <br />LATER 01 STUCCO WRAP) <br />THAT ELEC. WIRE PENETRATES <br />MGM ae :.OT <br />ABBOTT PARK <br />LOT #21 <br />BLK #9 <br />PX0j=T# <br />04181.000-2 091 <br />MODELe <br />,� 3EFB <br />2447—ROBIE <br />GARAGE BWMG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />TOMERI <br />WRB LAYER 02 (FORTIFIBER — - — - — - — — <br />COATIIWs OVER <br />BUILDING PAPER) <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAL <br />STUC001 C.V. FINISH <br />(SEE TYPICAL WALL <br />METAL LATH x—x—x—x <br />4 1 COAT OF PAINT WRACK- <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />secTloN� <br />ROLL PRIOR TO <br />GRADE '0' <br />METAL LATH <br />STUCCO <br />ELEC. METER INSTALLATION <br />PROVIDE STUCCO SCRATCH <br />FELT -PROVIDE <br />SEALANT AT ALL <br />WOOD OR i/16' ZIP WALL <br />COAT LARGER THAN THE ELEC. <br />INTERSECTIONS <br />IR <br />® <br />METER CAN OR METER CAN <br />SHEATHING <br />COMBO OR METER CAN AND <br />A. <br />AR <br />SELF—ADHESIVE FLASHING — — — — — <br />DISCONNECT <br />DRurr w 05/24/21 <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />O ELECTRICAL CONDUIT <br />8 <br />ST }=' ✓ <br />STEP <br />#(o-14a, <br />sc�1/4• = t-01 <br />R'1031.1 / ASTM C-841 .5 L <br />MIN. 2BS. <br />PENETRATION <br />s T <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELECTRICAL <br />9 <br />O <br />RECEPTACLE <br />A� <br />