38356 Sonnet Landing Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38356 Sonnet Landing Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:53:30 PM
Creation date
2/19/2025 12:25:24 PM
Metadata
Fields
Template:
Building Plans
Street #
38356
Location
Sonnet Landing Ave
Contractor
Dr Horton
Building Plans - Permit #
1702
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL V SELF-AD4.0 M <br />MEMBRANE PLA814NG OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEC IENCE OF FL4814NG TO BE, <br />)C: <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT GAP 18 TO BE SET M BED <br />:{- <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 18 TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AtUAY FROM JONT& <br />E-Z BEAD ALL AROUND <br />VENT-APPLY SEALANT ALL <br />r <br />JOINTS AND INTERSECTIONS <br />' <br />_ <br />APPLY SEALANT AT PERIMETER Or - <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL 61DES, )'' CAULKING • JOINT <br />i <br />I <br />ALL AROUND <br />I I <br />PER SECTION 11703.7 <br />Extatior k*dm and p196Eetlrg <br />BACKER ROD <br />I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />kInstallation <br />of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />' <br />orASTM 1787. <br />UFO LAYER M, <br />-X <br />STUCCO WRAP <br />I <br />HOODED VENT <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />URB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME - <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — • — • — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR -1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-I341-14a, MIN. 2.5 LBS. <br />PER 60. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT . <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THR814 <br />MAI ALI <br />UTL <br />1 <br />b' SELF ADHESIVE— <br />FLASHNG (INSTALL <br />PER MANUP. SPECS.) <br />BUILDNG PAPER. <br />UNDER QUICK FLA814' <br />A VENT PENETRATION <br />USCALE: KTS. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />19 <br />WOOD SHEATHING <br />WRB LAYER M, <br />STUCCO WRAP <br />1URB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' Or. MAX <br />1 f.EPTO it Mmaue� i <br />scl i <br />ADHESIVE PLABMMG, CLEAN <br />MASONRY 00"ORE APPLYIN <br />V FINISH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />8' <br />WRB LAYER M, <br />CUT OPENING IN <br />STUCCO WRAP <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />CUT 'X' INTO <br />WRB LAYER $11, <br />SELF -ADHERING <br />fX\ <br />STUCCO WRAP <br />MEMBRANE FLASHING <br />APPLY SELF-ADHERNG <br />WOOD SHEATHING <br />MEMBRANE FLASHING° <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER M <br />STEP 01 <br />STEP <br />1*2 <br />APPROVED <br />HOUSEWRAP <br />WRB LAYER M, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />® <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />_ <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLAS14NG OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FOWIF15ER <br />BUILDING PAPER <br />STEP #3 <br />STEP <br />#4 <br />APPLY E-Z BEAD <br />OVER 6C MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ CV. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />5TEF 05 STEP #6 <br />OELECTRICAL RECEPTACLE <br />1 N. RONALD REAGAN BL <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-774-4078 <br />wwwzbdesigngroup.com <br />AA #: 0003325 <br />M <br />P' <br />a <br />aJ <br />g <br />E <br />GI <br />d <br />D <br />b <br />c <br />4a <br />U1 <br />0 <br />�I <br />L <br />IP <br />SUBDIV. & L+OTABBOTT PARK <br />LOT #9 <br />BLK #11 <br />ROJECTIF <br />04181.000-09111 <br />MODEMa <br />4EBB <br />"1828-CALI" <br />GARAGE B WING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. Qj <br />JANP6,011 <br />Dw � 01/20/21 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />WA2 <br />