Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />STUCCO <br />TOP SIDEIS) AND BOTTOM <br />FINISH <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE ExHAuaT. <br />6' SELF ADHESIVE <br />WOOD CONSTRUCTION <br />SEn,a.v-e oR FLASHING To BE: <br />I. BOTTOM. 2_ SIDES, 3. TOP <br />OVER TOP t SIDES <br />X: <br />VENT CAP 16 TO BE SET N BED <br />SELF <br />WOOD SHEATHING <br />WOOD SHEATHING <br />OF SEALANT AT TOP AND <br />BIDER ONLY. SEALANT 18 TO BE <br />WRB LAYER 01, <br />S7>,O WRAP <br />.: <br />TOOLED SO AS TO DEFLECT <br />LNIT <br />STUCCO WRAP <br />WATER AWAY FROM JOINTS. <br />LAYER -2, FORTPIBER <br />:x; <br />E-z BEAD ALL AROUND <br />PREMANUF. DRYER <br />BUILDING PAPER <br />I <br />J� <br />VENT -APPLY SEALANT ALL <br />VENT CAP (SET IN <br />WRB LAYER 02, FORTIFIBER <br />METAL LATH <br />JOINTS AND INTERSECTIONS <br />CONT. SEALANT) <br />BUILDING PAPER <br />CONSTRICTION <br />'tro' TEXII p <br />RINIBN � WOOD <br />BACKER ROD <br />APPLY SEALANT AT PERIMETER OFND <br />NON MOVABLE FRAME AND STUCCO <br />FASTS! To WOOD STRUCTIRAL <br />ONALLALR SODS, Yi CAULKING * JOINT <br />SEALANT • <br />MEMBER • , O� MAX <br />I <br />TOP i SIDES <br />THICK, 3 COAT CEMENT <br />a cru <br />I <br />PERSECTION 03. <br />PLASTER <br />V To Al MID -WALL <br />SEEP ace <br />Exkdw kdhk O and 0laelerYlu <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />O'D DRYER <br />B <br />VENT (BLOCK) <br />Ye• TO Ya' MID -WALL <br />WEEP SCREED <br />_•,... <br />— <br />�- <br />_ <br />X. <br />X <br />Installation of exterior lathing and framing <br />WAP <br />, . AD�VSE FLASWM CLEAN <br />'`- <br />I <br />r <br />..1 <br />.X <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />6' SELF-ADHESIVE <br />�MASOIRY BFFOIE APPLYING <br />AP <br />x; <br />FLASHINGG <br />TEXTURED <br />STUCCO WI <br />HOODED VENT <br />BUILDING PAPER <br />WOOD FRAMED <br />FINISH . MAeoNRr <br />OVER •GUICK <br />— — — —I <br />WALL <br />HORIZONTAL WEEP SCREED <br />i•THIAC3COAT CEI-ENT <br />FLASHY <br />F_ <br />PLASTER <br />FRAME <br />TO BLOCK <br />METAL LATH <br />HORIZONTAL WEEP SCREED <br />W 5 LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />PIPE THROUGH / <br />WALL <br />( FRAME TO FRAME) <br />WOOD SHEATHING <br />6 <br />DRYER VENT (FRAME) <br />•• SELF ADHESIVE <br />FLASHING. (INSTALL <br />PER MANUF. SPECS.) <br />a' <br />BUILDING PAPER <br />D SHEATHING <br />UNDER 'GUICK FLASH' <br />WRB LAYER 'I, — <br />, <br />STUCCO WRAER P <br />CO WRAP <br />CUT OPENING IN <br />STUCCO WRAP <br />APPROVED HOUSEWRAP <br />LAYER $2, FORTPIBER <br />FOR BOX INSTALLATION <br />WOOD <br />DING PAPER <br />coNencTloN <br />CUT •x• INTO <br />VENT <br />PENETRATION <br />AL LATH <br />rwxm <br />A <br />STUGGOYWRAP <br />MEMBRANE FLHASHINCs <br />SCALE: N.T.S. <br />e' ow <br />1 ��'��APPLY <br />SELF -ADHERING <br />AISED BAND <br />SHEATHING <br />MEMBRANE FLASH04G <br />oWALLWOOD <br />P acREeD <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER -1 <br />STEP #1 <br />STEF #2 <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING., CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK; <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2S LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />t 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />A SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE '0' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP #3 <br />WRB LAYER 01, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />`IUM LAYER *2, FORTIMMER <br />BUILDING PAPER <br />STEP a4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />- <br />METAL LATH <br />STEP *5 STEP 116 <br />@)ELECTRICAL RECEPTACLE <br />1441 N. RONALD RFAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774E078 <br />FAX- 407-7744078 <br />www.abdesigrgmp.com <br />AA l: 0003325 <br />R <br />4 <br />� <br />9 <br />FnoABIBJOTT PARK <br />LOT #31 <br />BLK ECT/I <br />04181.000-31091 <br />1EDD�ia <br />3EAB <br />"1504— ALLEX" <br />OA>RAGN aMUM: <br />RIGHT <br />PAGM <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />r <br />01/19/21 <br />AM 1/4"=1'-0" <br />m= <br />WA2 <br />