My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38386 Sonnet Landing Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38386 Sonnet Landing Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:21:52 PM
Creation date
2/19/2025 11:37:26 AM
Metadata
Fields
Template:
Building Plans
Street #
38386
Location
Sonnet Landing Ave
Contractor
DR Horton
Building Plans - Permit #
1704
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BAGGER ROD <br />WPM LAYER -1, <br />STUCCO WRAP <br />INSTALL 6' SELF -ADHERING <br />MB15RAM FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />OF FLASHING TO BE. <br />X. <br />L BOTTOM. 2. SIDES_ 3. TOP <br />VENT CAP IS TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND NTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R 03.7 <br />ExMbr Wft and pWftrfn9 <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-16b. <br />X <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />- <br />or ASTM 1787. <br />rX; <br />HOODED VENT <br />X i' 3 GOAT CEMENT <br />I, PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTRIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - - - - - <br />BUILDINCs PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2B LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANIF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER *QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />-`VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />F11CCN IV IiCI.CIVC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />—"�'—ELEG. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />�R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:;O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER <br />STUCCO URb <br />WOOD SHEATHING <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />LAYER -1. <br />STUCCO WRAP <br />LAYER 4, FORTIFIBER <br />BUILDWS PAPER <br />METAL LATH <br />WOOD TgxrjwD <br />C4;0STI1Z=ION . P WSH <br />,—FASTEN TO WOOD STRUCTURAL <br />MB"0ER • T' O.C. MAX <br />v Cm <br />36. TO19 MI" Ilia., <br />y`}E@P pr_eFen <br />Lj <br />6' WDE STRIP aw <br />. ADHESIVE PLASHMG, CLEAN <br />.,� MASONRY BEFORE APPLYING. <br />FINISH • MASO►RY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCa <br />a' <br />WRB LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br /># <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER 'I <br />STEP #1 <br />STEP #2 <br />LATER 01, <br />WRISTU <br />co w <br />STucRAP <br />9 <br />STEP #3 <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHNG OVER <br />APROVED <br />HOUSEWRAP <br />® IffMEMBRANE FLASHING <br />UM LAYER R, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #5 STEP #ro <br />OELECTRICAL RECEPTACLE <br />.rs <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FA): 407-774,4078 <br />wwwatxfesigngr_ corn <br />AA ff: 0003326 <br />C <br />M <br />B <br />7 <br />h <br />O <br />e <br />� <br />�b�• <br />6 <br />N <br />w <br />E <br />0 <br />S <br />r <br />8Uj3DZV. ee LOT: <br />ABBOTT PARK <br />LOT #5 <br />BLK #11 <br />PROJECT# <br />04181.000-05111 <br />MODMU <br />4EBB <br />"1828-CALI" <br />'GARAGE DWINO: <br />LEFT <br />PA'GE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />
The URL can be used to link to this page
Your browser does not support the video tag.