HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MPG, REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS PAS 4 MASTIC, AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL UN CLASS i AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN m FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS $WALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS 814ALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601, <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTEC 4 DBF Im DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />SCORIATED NICKEL FN. FLOOR <br />BRONZE FL. F'L. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 560M <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />U)FL00R SLAB CLEAN -OUT (TYPE, <br />COL"TER8INIC <br />CA. PLUG <br />SEE SPEC. <br />r-s•X&' CONC. <br />FINGRADE <br />OR PAVING <br />FITTING OR <br />O <br />a <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN -OUT (TYPN ) <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER - <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRINK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRLI AIR GRILL <br />ATTIC <br />AIR SUPPLY�I j <br />AIR <br />EVAR TRAY <br />NOTE <br />ALL AC TO HAVE PROPER <br />PAN& W/ DRAMS <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONB UNIT SIMPSON WB ROLL STRAP <br />EXTERIOR WALL OR EQUAL <br />AIR RETURN <br />SUCTION AND LIQUID 4' CONCRETE SLASECURE STRAP TO UNIT W/ (2) <br />B <br />REFRIGERANT LINES '8XI I/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />E/4' PVC IAA" CONNECTION TO PAD <br />3/4' PVC CONDENSATE DRAM LINE <br />PVC SLEEVE TO LINES BELOW SLAB NOTE: MAIN COND. DRAIN 3/4' DIA <br />F11 <br />OVER HEAD • 12' FROM STRUCTURE <br />p REFRIGERANT LINES TO <br />RETURN CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC DRAINS <br />MECHANICAL PLAN <br />SCALE: V4 • I'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGNf00D, FL 32750 <br />PH: 407-774�6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA & 0003325 <br />all <br />b <br />s,x Div. ac 1,07 <br />ABBOTT PARK <br />LOT #4 <br />BLK. #11 <br />PURIOJECT# <br />04181.000-04111 <br />MoDE><. <br />3EAB <br />"1504- ALLEX" <br />0GAl2AGE 81rMG: <br />LEFT <br />PRS AE: <br />MECHANICAL <br />PLAN <br />160 VJPH FAC <br />OPRDgT 1/25/21 <br />SCALE 1/4"=1'-0" <br />SHEET <br />M1 <br />