My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38416 Sonnet Landing Ave
Zephyrhills
>
Building Department
>
Building Plans
>
38416 Sonnet Landing Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:36:30 PM
Creation date
2/19/2025 11:37:56 AM
Metadata
Fields
Template:
Building Plans
Street #
38416
Location
Sonnet Landing Ave
Contractor
DR Horton
Building Plans - Permit #
1661
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF-ADHERNG <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST.. <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM. 2 SIDES. 3. TOP <br />X: <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />I <br />VENT -APPLY SEALANT ALL <br />i <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />BACIMR ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES. Y.' CAULKING • JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R703.7 <br />I <br />ExEelior Ialfl m and p1es11x4NII <br />BACKER ROD <br />I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />- <br />requirements of ASTM C 926-18b. <br />X <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063319a, <br />l <br />or ASTM 1787. <br />WRB LAYER -4,i� <br />STUCCO WRAP... <br />HOODED VENT <br />]PLTH� 3 COAT CEMENT <br />TER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />rs, <br />SHEATHNG <br />_ING PAPER <br />CONSTt1CTION <br />METAL LATH <br />e' CMU VINYL CASING: BEAD <br />•' RAISED BAND <br />4 <br />x' TO R' r•nD-WALL <br />w�P PR'FtEED <br />W WIDE STRP SELF <br />ADHESIVE FLAS14W^ CLEAN <br />MASONRY BEFORE APPLYING <br />Z I'LASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />F)B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'OUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />LADDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T,S. <br />ELEC. METEF <br />VERIFY LO <br />AAM=114 11.w <br />ICGC.0 I V G <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />'-ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER02, FORTIFIBER <br />BUILDING PAPER <br />3 COAT CEMENT <br />76' TO Ya' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />I _`—� "' WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAMEZ <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (U LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />I "I cam• "" '�R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARGER? THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 1, <br />STUCCO WRAP <br />•210 <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP #3 <br />WOOD SHEATHING <br />LAYER 1. <br />STUCCO WRAP <br />WRO LAYER R, FORTF11BER <br />OUILDING PAPER <br />METAL LATH <br />CONSTRICTION <br />. y�� eH • WOOD <br />FASTEN To WOOD STIIUCIYP.AL <br />MEMBER • I'Or— MAX <br />a• uu <br />V To V Mro-WALL <br />PEEP SCREED <br />— A <br />m W WIDE STRIP SELF <br />^I° ADHESIVE FLAMNING, CLEAN <br />,-f MASONl1' BEFORE APPLYING <br />V— FNSH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />U1R5 LAYER 1, <br />STUCCO WRAP <br />WRB LAYER 1, <br />STUCCO WRAP <br />APPLY 60F MIN <br />SEMBRANE <br />9 <br />GRADE 'D' FELT <br />FLA <br />MEMBRANE FLASHING <br />® <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP S STEP #ro <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAK 407-7744078 <br />www.abdesigngroup.com <br />AA tt: 0003325 <br />r7 <br />E <br />� <br />h <br />� <br />hil <br />7D <br />R� <br />aysniv. at IAT <br />ABBOTT PARK <br />LOT #2 <br />BLK #11 <br />PROJMCT# <br />04181.000-02111 <br />HODSS.A <br />3EAB <br />1504- ALLE)" <br />OARAGR 211111111 <br />LEFT <br />PAGIM <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />