HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICNG, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED N NON-CONDIT(ONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC'tTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN GLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5, ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER F15C ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED IN ACCORDANCE TO FBC IT14 EDITION <br />(2020) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />B. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC NTH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />It. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRI AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />O O <br />EXTERIOR WALL <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE <br />SECE STRAP TO CONC. CONDENSER <br />W/ (2)-3A6'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />y <br />OR EQUAL <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SECURE STRAP TO UNIT W/ (2) <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />4' CONCRETE SLAB •SXI 1/4' SHT. MTL. SCREWS <br />T <br />REFRIGERANT LINES TO <br />CONDENSER UNIT <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />CONNECTION TO PAD <br />INANAPROVEDRAM,PER <br />FBCR NTH EDITION (2020)) <br />NOTE= MAIN CCND. DRAIN 3/4' DIA. <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />OVER HEAD • 12' FROM STRUCTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL ///-'' FIN. FLOOR <br />BRONZE FL. PL. / OR WALL <br />/ <br />COUNTERSUNK <br />CA. PLUG <br />/XI, <br />-- <br />SEE SPEC. <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />///--- REQUIRED <br />INSIDE / SERIES NICKEL DRAW TOP <br />CAULK / P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYPN) <br />FIN. GRADE <br />OR PAVING <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYPN) <br />E3 ---------� <br />I <br />I <br />�G <br />I I FROM OM <br />FI <br />BEDROOM #2 '°BovE� <br />III I I/ <br />12X8-----------------�I <br />- ---- 14X6 12X12 II I I z. , <br />PASS <br />BATH #2 THRU II <br />'r�----I I-------------------� s C <br />II . <br />X +' <br />x`•. KITCHEN <br />I I I I I I I <br />I <br />WH o <br />Am <br />1�iGl <br />i� <br />S. S/A <br />FROM I <br />ABOVE I �� <br />\ \�� <br />FIRST FLOOR MECHANICAL PLAN <br />SCALE. 1/4 • I'-0' <br />OR <br />1 N. RONALD REAGAN SL <br />LONGWOOD,FL32750 <br />PH: 407-774.8078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />n <br />SVSDIV. So LOT. <br />ABBOTT <br />PARK <br />LOT## 1 <br />BLK 11 <br />PROJECT# <br />04181.000-11112 <br />MODEL: <br />4EHB <br />"2605- HAYDEN" <br />GARAGE 8WING: <br />LEFT <br />PAOE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />60 WH EXP. <br />2021 <br />DA T'. 04/18/21 <br />8CALE: 1/4"=1'-0" <br />SHEET <br />M1 <br />