1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, RESIDENTIAL (FBCR), 5TH
<br />EDITION (2014) AND IN CONJUNCTION WITH ASCE 7-10.
<br />2. THE MINIMUM SUPERIMPOSED DESIGN LOADS AREAS FOLLOWS;
<br />A. FLOOR LIVE LOADS R301.5 (PSF)
<br />1. SLEEPING ROOMS
<br />30
<br />It. ATTICS N STORAGE
<br />20
<br />Ill. ATTICS NOUT STORAGE
<br />10
<br />IV. POOLROOMS
<br />75
<br />V. BALCONIES AND DECKS
<br />40
<br />Vt. STAIRS
<br />40
<br />VII. ALL OTHER ROOMS
<br />40
<br />B. FLOOR DEAD LOADS R301.4 10 (PSF)
<br />C. ROOF LIVE LOADS R301.6
<br />1. **MtNIMUM ROOF LIVE LOADS SHALL COMPLY NTH TABLE R301.6 OF THE FBCR 5TH EDITION (2014)
<br />D. ROOF DEAD LOAD (PSF)
<br />1. FIBERGLASS SHINGLES 17 (TCDL 7 & BCDL 10)
<br />11. CONCRETE TILES 25 (TCDL 15 & BCDL 10)
<br />E. WIND LOAD CRITERIA
<br />1. BASIC WIND SPEED VULT--1 50 MPH, VASD= 116 MPH
<br />11. EXPOSURE CATEGORY B
<br />Ill. WIND DIRECTIONALITY FACTOR (KD) 0.85
<br />IV. INTERNAL PRESSURE COEFFICIENT (GCPI)
<br />ENCLOSED BUILDINGS to.18
<br />V. RISK CATEGORY 11
<br />9. EXCAVATIONS TO BE A MINIMUM OF 3'_ O"BEYOND NEW FOOTING LINE.
<br />10. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION ASPER ALL LOCAL AND STATE REQUIREMENTS.
<br />11. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE ELEVATION
<br />OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING
<br />JURISDICTION, INCLUDING ALL APPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES.
<br />12. SUMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS,
<br />CONCRETE
<br />1. ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE
<br />IN BUILDINGS, ACI 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-08.
<br />2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLANEOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE
<br />STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND PROVISIONS OF R402.2.
<br />3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33-03. MAXIMUNI AGGREGATE SIZE SHALL BE
<br />4. PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER.
<br />5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BACKFILLING AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION
<br />UNTIL PERMANENT RESTRAINTS ARE INSTALLED.
<br />6. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED Y4.
<br />7. PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON
<br />DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE.
<br />1. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
<br />D. TRUSS PLATE INSTITUTE:
<br />1. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-1-07)
<br />E. APA - THE ENGINEERED WOOD ASSOCIATION:
<br />1. ENGINEERED WOOD CONSTRUCTION GUIDE
<br />F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
<br />2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE #2 (MIN.) MACHINE GRADED LUMBER, LINO.
<br />Fb = 1,500 PSI Fv = 175 PSI E = 1,600,000 PSI
<br />STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGBACKS, LEDGERS, BEAMS,
<br />HEADERS, AND POSTS.
<br />3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE SOUTHERN YELLOW PINE #2 (SYP #2) OR BETTER (UNLESS NOTED
<br />OTHERWISE).
<br />4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
<br />5. MINIMUM NAILING PER FBCR, 5TH EDITION (2014), SEE TYPICAL NAILING SCHEDULE ON PLANS.
<br />6. ALL BOLTS SHALL HAVE MINIMUM 2"SQUARE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT WITH WOOD.
<br />7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO SECTION R602.2.3 & R807 1.8. OF THE FBCR 5TH EDITION (2014).
<br />8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 7116"OSB EXPOSURE-1 OR 1/2"CDX PLYWOOD SHEATHING.
<br />PROVIDE PANEL -CUPS AT MID -SPAN FOR SPANS GREATER THAN 16"ON CENTER AND AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING.
<br />9. FOR CEMENTITIOUS TILE ROOFS, SHEATHING SHAJ_L BE 518' COX PLYWOOD. 518'CDX SHEATHING SHALL BE INSTALLED WITH THE
<br />STRENGTH AXIS RUNNING PERPENDICULAR TO THE TRUSSES AND SHALL SPAN A MINIMUM OF TWO TRUSS BAYS. PROVIDE PANEL -CLIPS
<br />AT MID -SPAN FOR SPANS GREATER THAN 16"ON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING.
<br />F. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING
<br />OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WIND BORNE DEBRIS BY THE INSTALLATION
<br />8. CONTRACTOR/OWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION.
<br />10. FLOOR SHEATHING SHALL BE APA RATED/' SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND SCREWED. ADHESIVES CONFORMING
<br />OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND
<br />WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED.
<br />INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, 5TH
<br />9. FLOOR ELEVATIONS AT REQUIRED EGRESS DOOR SHALL MEET PROVISION OF FBCR R311.3.1.
<br />EDITION (2014).
<br />11. WALL SHEATHING SHALL BE STRUCTURAL GRADE 7/16'OSB EXPOSURE-1 OR 1/2CDX PLYWOOD SHEATHING.
<br />MASONRY
<br />3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK
<br />1. MASONRY CONSTRUCTION SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 606 OR WITH
<br />12. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24"AND THE MINIMUM AREA SHALL BE 8 FT . SQ.
<br />PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />PROVISIONS OF TMS 402 1 ACI 530 / ASCE 5.
<br />13. PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LUMBER SYP #2.
<br />4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE
<br />2. CONCRETE MASONRY UNITS SHALL BE GRADE 'N'TYPE 11 OR EQUAL AND, IN ACCORDANCE WITH ASTM C90-06b, STANDARD
<br />ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR
<br />SPECIFICATIONS FOR HOLLOW LOAD -BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF Pm = 1500
<br />14. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL
<br />WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF
<br />PSI.
<br />POINTS AND SUBMIT TO THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS
<br />WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK.
<br />S,HAU_ BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED
<br />3. OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK.
<br />CONSTRUCTION.
<br />5. THE ARCHITECTIENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES,
<br />OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES.
<br />6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL
<br />SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL
<br />PERMANENT MEMBERS ARE COMPLETELY INSTALLED.
<br />7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS.
<br />8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECTIENGINEER.
<br />9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED.
<br />GARAGES AND CARPORTS
<br />1. GARAGE DOOR
<br />A. ENGINEERED FOR 150 MPH MIN. WIND LOAD.
<br />B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER
<br />C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER
<br />2. PER FBCR 5TH EDITION (2014) R30251: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES
<br />SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD
<br />DOORS NOT LESS THAN 13/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3/8 INCHES THICK,
<br />OR 20-MINUTE FIRE -RATED DOORS AND MUST BE EQUIPPED W1 A SELF -CLOSING DEVICE PER R307.5.1.
<br />3. PER FBCR 5TH EDITION (2014) R302.52 DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING
<br />THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL 1' MIN. RIGID
<br />NON-METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE,
<br />4. PER FBCR 5TH EDITION (2014) R302.6 &TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS AT -TIC
<br />AREA BY NOT LESS THAN % -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS
<br />SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR
<br />EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL
<br />ALSO BE PROTECTED BY NOT LESS THAN Y�INCH GYPSUM BOARD OR EQUIVALENT.
<br />SITE WORK
<br />I . REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS,
<br />2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, SITE
<br />IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE
<br />CONFLICTS WITH SITE WORK NOTED HEREIMSEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION.
<br />3. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGN WAS BASED ON
<br />AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED
<br />OTHERWISE.
<br />4. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT.
<br />5. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN % THE HORIZONTAL DISTANCE FROM THE
<br />NEAREST EDGE OF THE FOOTING.
<br />6. ALL BACKFILLAT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8" LAYERS AND
<br />COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE SHALL BE KEPT DRY SO
<br />THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS.
<br />7. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED.
<br />4. MORTAR SHALL BE TYPE M OR SIN ACCORDANCE WITH ASTM C270-07, STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY. 15. TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS,
<br />CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN
<br />5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 318 INCH THICK. THE BED JOINT OF THE STARTING COURSE MAY ACCORDANCE WITH ANSI A58.1-1982.
<br />VARY BUT IT SHALL NOT BE LESS THAN Y4 INCH AND NOT MORE THAN 3/ INCH, REFER TO FBCR 5TH EDITION (2014), SECTION R607.2.1
<br />FOR MORTAR JOINT THICKNESS TOLERANCES. 16. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX B OF
<br />THE ANSIlTPI 1-2007 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS
<br />A PD- 1 1 DC I� A-D-C -TU -A- OD-C-1-0 -D EAD -V DOI SHALL BE LIMITED TO U360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U240.
<br />ROCK CONCRETE PER SPECIFICATIONS AND PROVISIONS OF SECTION R609.1.2. OF THE FBCR 5TH EDITION (2014).
<br />7. FILL CAMU CELLS SOLID NTH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING.
<br />8. MASONRY WALLS SHALL BE LAID INA RUNNING BOND PATTERN OR, IFA STACK BOND PATTERN ISTO BE USED 9 GA. LADDERTYPE
<br />HORIZONTAL JOINT REINFORCEMENT IS TO BE INSTALLED IN THE BED JOINTS SPACED AT `115- ON CENTER (MAX).
<br />REINFORCING STEEL
<br />1. ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING
<br />REINFORCED CONCRETE STRUCTURES, ACI 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS,
<br />ACI 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318A.
<br />Z REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO).
<br />3. WELDED WIRE FABRIC SHALL BE 6"X 6"- WIA X WIA AND SUPPLIED IN FLAT SHEETS OR ROLLS CONFORMING TOASTM A185. LAP
<br />SIDES AND ENDS A MINIMUM OF 12'. LOCATE WWF T FROM THE TOP OF THE SLAB, UNLESS OTHERWISE NOTED ON THE PLANS.
<br />THIS REINFORCEMENT SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 3'-0".R506.2,5(2)
<br />4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, THICKENED SLAB, BEAM OR UNTEL
<br />SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS
<br />THROUGHOUT THE HEIGHT OF THE WALL, WITH LAP SPLICES OF AT LEAST 25.
<br />5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND
<br />HOOK AT ENDS. STAGGER SPLICES AT LEAST 25"WHEREVER POSSIBLE.
<br />6. CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE:
<br />A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH -3-
<br />B. CONCRETE EXPOSED TO EARTH OR WEATHER:
<br />1. #5, W31 OR D31 AND SMALLER 2'
<br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
<br />1. #11 AND SMALLER 3/4'
<br />D. BEAMS,COLUMNS:
<br />1. PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS I
<br />7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUT THE
<br />APPROVAL OF THE ARCHITECT.
<br />17. THE CONNECTIONS FOR ALL 11MBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TREATED LUMBER SHALL BE GALVANIZED OR
<br />PAINTED WITH A CORROSION RESISTANT POLYMER PAINT.
<br />18. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "SIMPSON" STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS
<br />NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NUMBER OF BOLTSNAILS AS RECOMMENDED BY THE
<br />MANUFACTURER IN THE LATEST CATALOG.
<br />19. DRAFTSTOPPING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.12. OF THE FBCR 5TH EDITION (2014).
<br />PLUMBING
<br />1 , SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL.
<br />2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX 'A' (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS.
<br />3. CONDENSATION LINES SHALL BE MINIMUM %' PVC (SCHEDULE 40), INSULATED WITHW AMAFUEX.
<br />4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH.
<br />5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE.
<br />6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES.
<br />7. SIZE AND LOCATION OF CLEANOUrS SHALL CONFORM TO SECTION P3005.2 OF THE FBCR 5TH EDITION (2014).
<br />8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903 OF THE FBCR 5TH EDITION (2014).
<br />9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE.
<br />10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2 OF THE FBCR 5TH
<br />EDITION (2014).
<br />EXTERIOR WALL COVERINGS
<br />1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR
<br />COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301,2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS
<br />SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE
<br />TIMBER WERIOR FINISHES
<br />1 . ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %' THICK,OVER FRAMED WALLS APPLIED OVER
<br />A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN TWO COATS, 1/2"THICK,
<br />B. NATIONAL FOREST PRODUCTS ASSOCIATION: WHERE APPLIED OVER MASONRY OR CONCRETE.
<br />1. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
<br />2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926 & ASTM-C1063-06.
<br />2-STORY GYPSUM BOARD
<br />UNDER STAIR PROTECTION:
<br />1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE
<br />ENCLOSED SIDE WITH 1/2' GYPSUM BOARD. FBCR R302.7. CONTROL DATE: 07/15115
<br />A R C H I T E C T $-I
<br />6
<br />m Ion
<br />G r ZousrO..!
<br />Ai N. RONALD REAGAN BJLVD.
<br />LONGWOOD, FL32750
<br />PH: 407-774-6078
<br />FAX: 407-774-4078
<br />u _
<br />www.abd�igngmp.com
<br />AA #: 0003325
<br />a,
<br />-7
<br />F-sulwiv. a Lo .4
<br />SILVERADO
<br />LOT 2
<br />BLK 1
<br />3PMJWT#
<br />04128.000-02001
<br />MODIIET
<br />4EBB
<br />"1828-CALI"
<br />GARAGZ OWMG:
<br />LEFT
<br />PAGE:
<br />GENERAL
<br />NOTES
<br />%t5O MPH EXP.
<br />ARCHrrr=CT-
<br />STATE OF FLONDA
<br />N
<br />r_pRn4T
<br />IDATIC- 09/19,
<br />SCA=: 1/4"=l'-O"
<br />skrm=
<br />G -k
<br />%� I
<br />
|