Laserfiche WebLink
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT 514ALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL L BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLDGG, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORM SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, WAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC TTH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10, GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRJNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />0/4 <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THM AIR GRILL <br />---------------------ROOF <br />- - - - - - - - - - - - <br />BELOW <br />I I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I I <br />I I <br />I 1 <br />-----------ROOF----- —J <br />BELOW <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4'.I'-C' <br />A RC N I T E C T E <br />Grou ion <br />441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL $2750 <br />PH: 407-774-6078 <br />FAX: 407-774.4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813486-2628 <br />FAX: 813-886-2802 <br />EiUHDIV. ac LiOT: <br />SILVERADO <br />LOT#2 <br />BLK 10 <br />PROJECT# <br />03719.001-02101 <br />MODEL: <br />3278—JORDYN II <br />GARAGE SKIING: <br />LEFT <br />PAGE: <br />SECOND FLOOR <br />MECHANICAL <br />PLAN <br />150 MPH E C <br />SCALE: AS NOTED <br />SHEET <br />M2 <br />