HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS °SHALL. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 01 CLASS 1 AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY EWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $HALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH POO 'ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG RECOMMENDATIONS AND FBC 'ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />m <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />MECHANICAL PLAN <br />SCALE: 1/4 • 1'-0' <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS 69>00 TOP <br />CAULK P.V.0 OPTI/SPEC <br />(D LOOR SLAB CLEAN —OUT (TYP. ) <br />COUNTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN —OUT (TYPN ) <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />"SXI I/4' BHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING O O EXTERIOR WALL <br />PLENUMX�REFRIGERANT <br />ETURN <br />ON AND LIQUID <br />AIR SUPPLY LINESAIR HANDLERRIOR WALL <br />VC CONDENSATE DRAIN LINE <br />EVAP. TRAYLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORMCONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />POOR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION W1.2A <br />HVAC DRAINS <br />A R C N I T E C T 5 <br />6 <br />Gr * i In <br />41 N. RONALD REAGAN BU <br />LONGWOOD,FL32760 <br />PH: 407-774,6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 000332E <br />k <br />Qi <br />4 <br />0 <br />a <br />0 <br />F <br />i; <br />aUBDIV. ac L:OT <br />SILVERADO <br />LOT# 26 <br />BLK. 10 <br />PROJECT# <br />03719.001-26101 <br />MODEL.• <br />"2558-HAWTHORNE" <br />GARAGE OWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 JIPH W. H <br />DAR� 07/15/21 <br />9CAL M: 1/4"=1'-0" <br />SHEET <br />M1 <br />