INSTALL WSELF-ADWERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(W AND BOTTOM <br />ILAW3E. OF -MOVABLE <br />FRAME Or THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE: <br />X, <br />1. BOTTOM, 1 SIDES- 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED 90 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />.1 <br />VENT -APPLY SEALANT ALL <br />x <br />JOINTS AND INTERSIECTIONS <br />APPLY SEALANT AT PERIMETER OF; <br />BACKER ROD <br />NON-MOVASLE FRAME AND STUOCO <br />ON ALL SIDES, Y.' CAULKINd. a JOINT <br />ALL AROUND <br />I <br />PER SECTION R703.7 <br />Exterior lathing and pleaWrIna <br />BACKER ROD <br />I <br />bderior use of portland cement plaster <br />I I <br />shall comply with the application <br />-7 <br />requirements of ASTM C 926-18b. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-1 9a, <br />or ASTM 1787. <br />WRI5 LAYER -1, <br />STUCCO WRAP <br />WOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WIRS LAYER -2, FORTIF115ER <br />]BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />A <br />WOM SHEATHING <br />L'� ER _X-IFISER <br />M PAIIEIR <br />METAL LAT14 <br />C"j VINYL CASM DEAD <br />6' RAISED BAND <br />6' WIDE STRIP SELF <br />A01411SIVE FLASHM, CLEAN <br />MASONRY BEFORE APPLYINdr <br />Z FLASHW. <br />STONE VENEER <br />OVER SOIIATC44 COAT <br />HORIZONTAL WEEP SCREED <br />W STONE VENEER <br />(FRAME TO BLOCa <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — --— <br />BUILDING PAPER) <br />METAL LATH X—X—X—x <br />STUCCO <br />WOOD OR -1/1W ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING <br />NOTE. <br />METAL LATH. LATH TO BE PER SECTION <br />R103.11 / ASTM C-841-14a, MIN. 2.5 LBS. <br />PER 50, YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEII <br />VERIFY LO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUP. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT� <br />5F:ALANT* <br />TOP 4 SIDES <br />DRYER VENT (BLOCK) <br />BUILDING PAPER — <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH--� <br />WALL <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUIF. SPECS.) <br />BUILDING3 PAPER - <br />UNDER 'GlUICK FLASH' <br />A VENT PENETRATION <br />SCALE; N.TS. <br />STUCCO SCRATCH COAT <br />4 1 COAT OF: PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />_""ELEC. METER FIELD <br />VERIFY LOCATION <br />CL-AsISTRUCTION <br />WOOD SHEATHING <br />WRIB LAYER 01, <br />STUCCO WRAP <br />WRIB LAYER 02, FORTIF15ER <br />5UILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />Ys' TO Ys'MID-WALL <br />WEEP SCREED <br />1-6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />RIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO ME FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />- -- A � � .. .- <br />R SIMILAR/ <br />APPLY A SILICON <br />5ASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COM50 OR METER CAN AND <br />DISCONNECT <br />ELECTRICAL CONDUIT <br />PENETRATION <br />OUT OPENING IN <br />APPROVED WOUSEURAP <br />FOR BOX INSTALLATION <br />WR5 LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />I YorjP <br />�toQ, <br />m 1 124 <br />WOOD SHEATHING <br />WIREI LAYER -1, <br />STUCCO WRAP <br />WIM LAYER 02, FORTIFIBER <br />IBUILDIW. PAPER <br />METAL LATH <br />.I/A'TEXTURED <br />FINISH * WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER 0 1" Or— MAX <br />.36* TON <br />UIREP & <br />ADHESIVE FLASHW3, CLEAN <br />MASONRY BEFORE APPLYW. <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />1. <br />WR15 LAYER <br />STUCCO WFU <br />CUT 'X' INTO <br />SELF-ADHEIRING; <br />MEMBRANE FLASHI14G <br />APPLY SELF-AIDWERNS <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRIB <br />LAYER 01 <br />5TEF 01 5TEF *2 <br />HOUSEWRAP <br />WRIB LAYER 01, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT— <br />APPLY 60 MINI <br />— <br />—SELF-ADWERIWA <br />NO MEMBRANE <br />GRADE '0' FEL' <br />MEMBRANE FLASHING <br />ENTER$ BOX, <br />OVEP <br />APPLY TO FAC <br />SELF -ADHERING; <br />E <br />EDGE <br />FLASHING OVER <br />APROVED <br />kOUSEWRAP <br />WRIB LAYER 42, FORTIP15ER <br />IBUILDING PAPER <br />5TEF *3. <br />5TEF 114 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING; OVER <br />STUCCO/ C.v. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH S <br />6TEF 05 6TEF I*& <br />(-9)ELECTRICAL RECEPTACLE <br />A R C N I T E C T 111171 <br />6 <br />Er%ft , <br />lesi n <br />rou <br />GaSO.n2c.- <br />1441 N. RONALD REAGAN BLVD. <br />kN BLVD <br />LONGWOOD, FIL 32750 <br />PH; 407-77"078 <br />FAX: 407-774-4078 <br />www.abdesigngroup'.com <br />AA #: 0003325J <br />ro <br />PSUDDIV. & U074 <br />SILVERADO <br />LOT #3 <br />BLK #10 <br />PROJECT# <br />03719.001-03101 <br />MODEL. <br />"2045-LANTANA" <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%150 MPH EXP. Bj <br />I 21A 1 <br />F`PRINT 08/18/21 <br />DATE: �u <br />SICALM: 1/4"=1'-0" <br />S*1EET <br />W,2 <br />