FOR ASPHALT SHINGLE ROOF, USE MIN 7/16'STRUCTURAL <br />SHEATHING EXP 1(24M6) oT 15/32" STRUCTURAL SHEATHING EXP 1 <br />(32t`16), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15/32' <br />STRUCTURAL SHEATHING EXP 1 (32116) .(SEE TABLE FOR FIELD AND <br />EDGE SPACING) SEE DETAIL. <br />ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN <br />NAILS@4"O.C. EDGEWISE 2X4 BLOCKING ALL PANEL JOINTS VVI IN 4' <br />OF GABLE END. <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL REQUIREMENTS <br />SIZE <br />HEAD <br />LENGTH <br />DIA <br />TENSILE STR. <br />SHANK <br />ASTM <br />SO <br />RINGSHANK, <br />318.. <br />0113 <br />170,000 <br />RING <br />1 -2 RIN <br />6 G. <br />OINCH) <br />-7., <br />FSR. <br />SCREW SHANK <br />ER <br />8d <br />RING SHANK, <br />H <br />PNEUMATIC <br />2316. <br />0113 <br />F 667 <br />I <br />SCREW -NAILS <br />RSRS-01 <br />EXTERIOR SHEATHING <br />USE lfZ'CDX OR 7116'O.S.8 PLY WITH Scl RING SHANK GUN NAILS AT <br />4" 0 C, AT PANEL SIDES AND Bd RING SHANK GUN NAILSVO.C. TOP & <br />BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT e'O.C. AT <br />�NTERMEDIATE SUPPORTS OR 7116" ZIP SHEATHING SYSTEM <br />INSTALLED PER MANUF. SPECS.) SEE DETAIL. <br />ROOF SHEATHING ATTACH9�� SPAQNG <br />ZONE 1 3d NAILS a C. ON EDGE AND 6'O.C. IN F�ELLDD <br />ZONE 2S 2n,2r 8d NAILS@ 4"O,C. ON EDGEANDV'O.C. IN FE <br />ZONE 3,3e, 3r. Scl NAILS @ 4" O.C. ON EDGE ANDV'O,C IN FI ELD <br />NOTE'. ROOF SHEATHING THICKNESS WAS CALCULATED <br />AND ADHERES TO ASCE 7-16 <br />z <br />Z Q <br />,a <br />W <br />z <br />10 q <br />z <br />8d RING SHANK GUN NAILS @ 4" O.C. <br />.1 TOP & BOTTOM EDGES I <br />TYP. EXT. SHEATHING ATTACHMENT <br />11 <br />� 'A' <br />< <br />z <br />z 0 <br />D 0 <br />0 w <br />� a <br />z <br />< d <br />0 T. <br />z <br />D' <br />cj <br />RAFTER OR TRUSS <br />ROOF SHEATHING <br />rm rill, I <br />BUILDING LENGTH <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL BRACING <br />FOR GABLE END FRAMING <br />NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED <br />TRUSS 214 #2 SYP OUTLOOKER RAFTER Wl BLOCKING a <br />16.0 C IF NO DROPPED GABLE END ' ATTACH 2x4 #2 SYP <br />13LOCKING 0 16" O.C. FIRST 4 BAYS VVI (2)12d NAILS EA <br />END. ATTACH ROOF SHEATHING TO RAFTERS 21 <br />BLOCKING PER NAILING SCHEDULE <br />8d RING SHANKGUN NAILS <br />SEE:ROOF SHEATHING ATTACHMENT' <br />TABLE FOR FIELD SPACING <br />C#8*2' DECK SCREWS' 0 6�6' O.C. MAX' @ <br />EDGES & 12'0 C, MAX IN FIELD. UNTHREADED <br />SHANK TO EXTEND BEYOND THICKNESS OF <br />SUB -FLOOR SHEATHING <br />TYP 314!'T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />NET "" ROOF D DESIGN PRESSURES <br />IN <br />E". <br />I ZONE 3 <br />Z-E— 5, <br />­—N-ONEDSTANC. <br />E­WRECATTRY V� <br />NlWlAj,_ <br />APPLOASL — <br />PRESSURE COEF—ENT -1 018 <br />FASTENER SCHEDULE <br />WINDOWAN <br />DOOR BUCK FASTENERS <br />FASTENER <br />A-1— <br />SIZE <br />TYPE <br />S—No <br />R- - KS <br />­Tm <br />SIZE <br />IPE <br />S_No <br />REM—S <br />1. PT —1. 1. <br />I — <br />ODL <br />.—E-- <br />To <br />- .1 <br />N. <br />—TENER <br />M <br />I — EMBED, 4- END DST, <br />I lo� EDGE DST <br />SGD ­EXTDOORS <br />CAS—RDENE—L <br />N— FA —El <br />I—E DOCR <br />�UA) <br />4- ..E., I END <br />1, PT SEE NOTES <br />S —EREO <br />TO <br />EXIAN.— ­T <br />24 DA) <br />S­ -T <br />­­ <br />CNEE —8- <br />ME— ST­ TO <br />CONTACT THIS ENGINEER FOR SPACING <br />1.1 SEENOTE. <br />NAL I — LONG <br />STA=ERED <br />WMW000WR/yFA <br />o _ 1�=ED <br />— <br />REQUIREMENTS <br />E� -1. DOOR <br />L­ � PT, SEE NOTES <br />q) S­ <br />NO <br />"T <br />F.A.,NER <br />Dl�ll I E..E. S' No <br />—E.. <br />N.—NING <br />TO <br />WIZIER BOLT US 1`�-W �E T.-T <br />PT <br />PT TO STER OX 0 131— x 2 1� ST. I <br />NOTE 6 Wi—SHER —­E. E.—T <br />NOTES <br />I.S LES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2 FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE ASPER MANUFACTURERS SPECS AND/OR NOA <br />3 ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4 PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5� FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />6. AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME, lx MEMBERS ARE NAILED AND <br />= SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE <br />2,=SARE <br />GENERAL NOTES: <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECI FCATIONS AND <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWNGS. CONSULT <br />ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS FBC-R 2020,7th EDITION <br />ACI 310-14, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, TMS 4021602-16 AISI SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONS <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTR ED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT VMERE A DIFFERENT DETAIL IS SHOWN. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOULOWWRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />TO THE ATTENTION OFTHEARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />OF THE WORK. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE -DOWNS. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />REQUIREMENTS AND SLA13-ON-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />Do NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR <br />To WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />DESIGN LOADS: <br />ROOF: LIVE LOAD FLOOR LIVE LOAD 40 pf <br />20 psf TOP CHORD —n-Ooncurrent <br />10 psf BTM CHORD -non-Ooncu-nt <br />DEAD LOAD DEAD LOAD <br />15 pSf TOP CHORD 20 pSf TOP CHORD <br />(7 psf wl ASPHALT SHINGLES) (10 PET wl No GYPCRETE) <br />10pSfBTM0H RD 5 pEf BTM CHORD <br />DEAD LOAD TO RESIST VAND UPLIFT 10psf <br />BALCONY LIVE LOAD 60 DST <br />STAIRS LIVE LOAD 40 psf <br />WIND� DEAD LOAD SPEED =1 50 MPH 3- SECOND GUST <br />(ASCE 7-16 (FBC R2020) EXPOSURE B, RISK CATEGORY 11) <br />LIVE LOADS UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WITH LIMITED <br />STORAGE: 20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR) <br />AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS 50psf, PASSENGER <br />VEHICLE GARAGES: 50pf, ROOMS OTHER THAN SLEEPING ROOM: 40pe, SLEEPING ROOMS 30psf, STAIRS: <br />40PSf <br />SHOP DRAWING REVIEW: <br />SHOP DRAVANGS VALL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC <br />ALL SHOP DRAWl GS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT <br />DRAWINGS SUBMI TED WITHOUT REVIEWWILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAVIANGS (CON -TRACT DOCUMENTS) ARE PROHIBITED <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAV41NGS CHECKED, UNLESS OTHERVASE SPECIFIED IN <br />WRITING BY THE ARCHITECT. <br />FOUNDATION/ SITE PREPARATION: <br />FO TINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING <br />EXCAVATIONS AND SLAB SUB�GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF THE <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMI NED IN ACCORDANCE WITH ASTM D-1 557. TREAT ALL <br />SOIL FOR TERMITE PROTECTION. <br />TH OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />SUCCESSFU COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE <br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL <br />BE MADE BY THE GEO-TECH. ENGINEER. <br />CONCRETE: <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS <br />2 500 P I REGULAR WEIGHT FOR FOOTINGS, AND SLA13-ON-GRADE <br />3:000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5' STRUCTURAL TERRACE SLAB. <br />CONTRACTOR SHALL SUBMIT PROPOSED WX DESIGNS, NTH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MX PRIOR TO <br />CONCRETE PLACEMENT. CONCRETE SLUMP SH&L NOT EXCEED 5'4� PRIOR TO THE ADDITION OF PLASTICIZER. <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33fC33M. MAXIMUM AGGREGATE SIZE SHALL BE SO'. <br />WOOD: <br />PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. <br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3/4'. <br />ALL WOOD FOR BEAM S, BEARING WALLS, SOLE P LATE S, TOP PLATES, B RACI ING, LE DGERS, SLOCKI NG, <br />CRIPPLERS, SILLS, ETC, SHALL BE SOUTHERN PINE NO 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF <br />PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS�ON �GROUNID WHERE INDICATED ON <br />ELASTICITY = 1,400.000 PS. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />DRAWNGS. SEAMS LAPPED 6 INCHESAND SEALEDWTH ADHESIVETAPE. <br />PRESSURE TREATED PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES <br />8 ILL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT DISODIUM <br />FORM -WORK- <br />CORROBORATE TETRAHEDRAL (DOT) WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0 42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE NTH ACI 347 LATEST <br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT <br />EDITION,"RECOMMENOED PRACTICE FOR CONCRETE FORM -WORK. <br />CONTAINS MORE THAN WOF HEARTWOOD <br />EXCLUSIONS FROM THESE PLANS: <br />MINIMUM NAILING PER PBCR 2020,7th EDITION. SEE NAILING SCHEDULE ON PLANS. <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURALDEPENDING <br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS <br />SYP #2. <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />WELDED WIRIE MESH: <br />AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />WELDED WIRE MESH, SHALL BE ASTM AiO641AI064M, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE <br />WOOD TRUSSES: <br />A I TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL <br />BE SUPPORTED WITH 2"CHAIRS SPACED T-0" OC, EACH WAY <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR <br />S RESS-GRADE LUMBER AND ITS FASTENINGS'BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />REINFORCING STEEL: <br />REBAR SHALL BE ASTM A615A615M GRADE 4D I N CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A61 5 <br />GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE <br />W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. <br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWNGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL <br />AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S <br />REVI EW <br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR 25" #6 BAR 36" <br />*5 BAR 30" #7 BAR 42" <br />PROVIDE 36'x 36'CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />FOR ADDIT1014AL INFORMATION. <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A446/A446M, GRADE A, AND SHALL BE HOT�DIPPED GALVANIZED <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-1 4, "DESIGN NATIONAL <br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION., AND "BCSI LATEST EDITION" <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER W UL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSIUASCE 7 88 1990. <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH <br />MIN IMU M 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />WALL. TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE <br />WITHOUT THE APPROVAL OF THE ENGINEER. STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />P ROV DE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />MASONRY: P LANSHOWING OMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE LICENSED PROFESSIONAL ENGINEER. <br />"SPECIFICATION MASONRY STRUCTURES" JMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY <br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />THE MASONRY STANDARDS JOINT COMMITTEE. CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE f� = 2000 PSI. BLOCK SHALL BE PLACED USING OF THE DELEGATED TRUSS ENGINEER. WND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT <br />RUNN NO BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE 13EAMS BEFORE AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />PLACING CONCRETE FOR INAVALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ALL TRUSS TO TRUSS CONNECTIONS. <br />ASTM C476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 318" <br />COURSE AGGREGATE, AND SHALL BE PLACED W1 A SLUMP OF 8" TO 10", USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />CELLS TO BE FILLED. <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANDIOR VERTICAL <br />REINFORCING, <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />STRUCTURALSTEEL: <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM <br />A36/A36M Py = 36 kSi FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM <br />A50WA506M, GRADE B, Fy = 48 W. STRUCTURAL PIPE SHALL BE ASTM A53IA53M, GRADE B, TYPE E OR S, Fy <br />35 W. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />A CHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL <br />OTHER BOLTS SHALL BE ASTM F3125/F3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS <br />SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN-OFF4HE-NUT METHOD. <br />CONCRETE SHALL COMPLY NTH ALL THE REQUIREMENTS OF ACI 318 AND ASTM C94IC94M OR MEASURING, MIXING TRANSPORTING ' ALL ANCHOR BOLTS SHALL BE GALVANI ZED STEEL. J-BOLTS ARE TO BE STEEL <br />ETC. CONCRETE TICKETS SHALL BE TIME TAWED WHEN CONCRETE IS BATCHED THE MAXIMUM TIME ALLOWED FR6� WHEN <br />WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON <br />THEREISA ELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MNUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL <br />BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY <br />NON COMPLIANCE NTH THE ABOVE. <br />REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS <br />A 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): <br />B FOR CONCRETE EX SED TO EARTH ANDIOR WEATHER <br />1 -10 FOR 05 AND SMALLER <br />TFOR 06 AND LARGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />314* FOR SLABS, WALLS AND JOISTS <br />1-112" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS <br />F—A R C N I T E C T 8 -1 <br />6 <br />lxsi Wn <br />G r abuspO.!_ <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />L AA #: 0003325 <br />[a. <br />F'suaDiv. ac W7,;l <br />SILVERADO <br />LOT #3 <br />BLK #10 <br />Plt0jzcT# <br />03719.001-03101 <br />MODET- <br />"2045-IJWANA7 <br />GAItAGE SWING: <br />RIGHT <br />PAGE: <br />DETAILS <br />150 MPH EXP. <br />rpr.tn,rr -1 <br />DATE: 08/18/21 <br />scALE: 1/4"=l'-O" <br />SHEET <br />SN1 <br />