My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6637 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6637 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:44:55 PM
Creation date
2/19/2025 12:17:14 PM
Metadata
Fields
Template:
Building Plans
Street #
6637
Location
Cobble Bliss St
Contractor
DR Horton
Building Plans - Permit #
2578
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHAL.L. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $HA4LL, BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL IN CLASS I AIR DUCT AS PER NPPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT CUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFOWS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -GUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECI-1 DEIF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />COUNTER —14011 C <br />C.O. PLUG <br />SECURE STRAP TO CONC. <br />CO DENSER <br />FIN. GRADE <br />W/ (2)-3/I6'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP OR PAVING <br />OR EQUAL <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB <br />"SXI 1/4' SHT. MTL. SCREWS <br />CONDENSER <br />UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />I9 <br />PASS-THRU AIR GRILL <br />SEE SPEC. <br />1'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (TY <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />SCORIATED NICKEL <br />FIN. FLOOR <br />O O <br />EXTERIOR WALL <br />BRONZE FL. PL. <br />OR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />T/ <br />6UCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />BRASS PLUG <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />FITTING OR EXTENSION TO <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SOIL OR WASTE AS <br />REQUIRED <br />EVAP. TRAY:�, <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />WADE 0240-K JOSAM 56000 <br />T <br />REFRIGERANT LINES TO <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />CAULK <br />P.V.0 OPT[/SPEC <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBGR 1TH EDITION (2020) <br />INv. SEE <br />MECHANICAL BLDG. CODE <br />TSITE PLAN <br />SECTION 301.2.4 <br />HVAC <br />DRAINS <br />a)FL00RSLAB <br />CLEAN -OUT (TYP <br />O <br />I <br />� <br />CASUAL <br />DINING <br />COVERED <br />LANAI <br />I <br />S <br />I <br />I <br />BDRM 2 <br />KITCHEN <br />I <br />n <br />I <br />� <br />GREAT <br />I <br />' <br />x <br />ROOM <br />, <br />L <br />I <br />ISxI <br />H <br />u <br />2 <br />14x11 <br />8 <br />- 4 <br />N <br />— <br />iv <br />— <br />10x10 <br />I I <br />12' S/A <br />-- ---- <br />I <br />18x18 <br />g FROM <br />ABOVE <br />g <br />— <br />— <br />I <br />I I I <br />4 8x4 <br />I <br />I I I <br />I <br />PANTRY <br />a <br />x <br />x <br />II <br />m <br />FOYER <br />I I <br />FLEX <br />r <br />ROOM <br />10, S/A <br />- <br />FROM <br />II <br />ABOVE <br />GARAGE <br />II <br />II <br />II <br />II <br />---O <br />O <br />O <br />I <br />II <br />ENTRY <br />I <br />ENTRY <br />—-------n---------------- <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4' • I'-C' <br />A R C N 1 T E C T 3 <br />GDes�n <br />rou LLB <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />w .abda lgngroupxom <br />AA #: 0003325 0 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SURE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-886-2628 <br />FAX 813-886-2802 <br />SSTHDIV. de LAT: <br />SILVERADO <br />LOT #8 <br />BLK #10 <br />PROJECT# <br />03719.001-08101 <br />moDEIA <br />3278—JORDYN II <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />LAN <br />15 H E <br />AJ <br />29 <br />DATE+ 06/25/21 <br />SCALE: AS NOTED <br />SI�ET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.