A -(I) SIMPSON HETA16 TRUSS ANCHOR WITH
<br />(9)10d x 1 }" NAILS TO TRUSS
<br />842) SIMPSON HETA16 TRUSS ANCHOR WITH
<br />(12)16d x 1 }'NAILS TO TRUSS
<br />DBL STRAP, 1 EACH SIDE WRAPS UP AND
<br />OVER TRUSS (NOT SHOWN)
<br />C{1) SIMPSON LGT2 GIRDER TIEDOWN WITH
<br />(16) 10d x 3 }" NAILS TO GIRDER AND
<br />(2) SIMPSON HETA16 TRUSS ANCHORS
<br />WITH (12)16d x 3 }'NAILS TO GIRDER
<br />1x2, 2x WOOD FASCIA
<br />SEE ARCHITECTURAL
<br />2x SECURED W/ (3)16d
<br />GALV. COMMON NAILS.
<br />lx2 SECURED W/ 10d
<br />GALV. COMMON NAILS
<br />12' O/C
<br />MASONRY BOND BEAM
<br />SEE SCHEDULE
<br />PLYWOOD SHEATHING, SEE
<br />"ROOFANALUFLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE"
<br />NOTE: A PT SYP #2 Z' x 4",
<br />6", 8" x 4'-0" MAY BE ADDED
<br />W/ 10d NAILS, 2 ROWS, 3'
<br />O/C TO FACILITATE ONE
<br />ADDITIONAL PLY MAX. TO
<br />ACCOMMODATE TRUSS
<br />ANCHOR REQUIREMENTS.
<br />ENGINEERED WOOD
<br />TRUSSES @ 24" O/C,
<br />SUBMIT SHOP DRAWINGS
<br />FOR REVIEW
<br />AND APPROVAL
<br />A ALLOWABLE UPLIFT = U:1810 LBS, L:770 LBS (1 PLY)
<br />B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY)
<br />C ALLOWABLE UPLIFT = U.2705 LBS (2 PLY)
<br />81 1 B 4 C TYPICAL TRUSS/
<br />I f•l r" I" GIRDER CONNECTOR(S) SCALE: 3/4"=1'-0"
<br />SS
<br />SERE
<br />BACKERBLOCI(
<br />THMESS
<br />4500
<br />3/4" WOOD PANELS
<br />6000
<br />(2) 12" WOOD PANELS
<br />60
<br />(2) 12" WOOD PANELS
<br />90
<br />2x LUMBER
<br />3/4" T & G SUBFLOOR GLUED AND
<br />SCREWED AS PER SCHEDULE
<br />PRE-ENG I -JOIST
<br />5/8" GYPSUM BOARD OR 1/2' HIGH
<br />STRENGTH CLG. BOARD
<br />SECURE I -JOIST TO TOP PLATE
<br />W (2) 12d TOENAILS
<br />DOUBLE TOP PLATE
<br />2x4 OR 2z6 WOOD BEARING
<br />WALL W/ SYP No 2 STUDS SEE
<br />PLANS FOR SPACING. SINGLE
<br />BTM. PLATE TO BE PT.
<br />PROVIDE DBL. TOP PLATE
<br />PROVIDE BLOCKING
<br />12" GYP. WL. BD.
<br />SEE SHEET St. to FOR
<br />NAIL SIZE AND PATTERN
<br />�,�I-JOIST CONNECTION @ L.B.W.
<br />�+ SCALE:3/4"=l'-(I(NO UPLIFT)
<br />OUTER 113 OF
<br />SPAN ONLY
<br />BTM.-
<br />PLATE
<br />DEPTH 1/4•0
<br />—HOLE EDGE >5/8"
<br />—HOLE DIAMETER
<br />215•0 SGL. STUD
<br />HOLE EDGE >5/8"
<br />01
<br />HOLE DIAMETER
<br />< 3/5•D DBL STUD
<br />STUD NOTCHING
<br />AND BORING LIMITS
<br />v
<br />SCALE: 1 12"=1'-0"
<br />ENGINEERED WOOD TRL
<br />24" O/C, SUBMIT SHOP
<br />DRAWINGS FOR REVIEW
<br />ANDAPPROVAL
<br />(1) SIMPSON HETA16
<br />TRUSS ANCHOR WITH
<br />(9) 10d x 1 }" NAILS TO
<br />GIRDER. PROVIDE 5"
<br />MINIMUM CONCRETE
<br />EMBEDMENT. USED IN
<br />CONJUNCTION WITH
<br />HEAVY UPLIFT
<br />CONNECTOR
<br />PLYWOOD SHEATHING, SEE
<br />"ROOFNJALUFLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE"
<br />NOTE: APTSYP#22"x4",
<br />6, 8" x 4'-0" MAY BE ADDED
<br />W/ 10d NAILS, 2 ROWS, 3"
<br />O/C TO FACILITATE ONE
<br />ADDITIONAL PLY MAX. TO
<br />ACCOMMODATE GIRDER
<br />TIEDOWN REQUIREMENTS.
<br />1—A41) SIMPSON LGT3-SD62.5 GIRDER TIEDOWN
<br />WITH (4) J' x 5" TITEN HD TO CMU AND (12) SDS
<br />}' x 2 }" TO GIRDER
<br />B{l) SIMPSON FGTR GIRDER TIEDOWN WITH
<br />(2) j' x 5" TITEN HD TO CMU AND (18) SDS }" x
<br />1x2, 2x WOOD FASCIA
<br />3" TO GIRDER
<br />SEE ARCHITECTURAL
<br />C42) SIMPSON FGTR GIRDER TIEDOWNS WITH
<br />2x SECURED W/ (3)16d
<br />(2) j" x 571TEN HD TO CMU AND (18) SDS }'x 3"
<br />GALV. COMMON NAILS.
<br />tx2 SECURED W/ 10d MASONRY BOND
<br />SCREWS TO GIRDER (EACH TIEDOWN)
<br />GALV. COMMON NAILS BEAM
<br />ENSURE THAT CELLS ARE GROUTED
<br />12' O/C SEE SCHEDULE
<br />SOLID, 6' EACH WAY OF BOLTS
<br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY)
<br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.)
<br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.)
<br />2A 2B 2C TYPICAL ROOF
<br />GIRDER CONNECTOR(S) SCALE: 3/4"=1'-0'
<br />F
<br />SERIES
<br />8ACm BLOCK
<br />THEKNEB8
<br />4500
<br />3/4" WOOD PANELS
<br />6000
<br />(2) 1/2' WOOD PANELS
<br />80
<br />(2) 12' WOOD PANELS
<br />90
<br />2x LUMBER
<br />LSTA1220 GAUGE
<br />W/ 1'dx1/2 HDG COMMON NAILS.
<br />EACH END TOTAL OF 10
<br />LVUI-JOIST WITH
<br />BACKER BLOCK
<br />HTT4 W/ 5/8" A. B. WITH
<br />MIN. 7" EMBEDMENT
<br />IL L2-l'Nlll_l
<br />& (18)16d x
<br />TO POST.,ITDIRECTLY
<br />LVL/WOOD POST CONNECTIONS
<br />5
<br />NOTE:
<br />A - WHEN TRUSS BEAR ON TOP OF LEDGER USE SIMPSON HTS20 FROM
<br />A - SIMPSON HUS28 G < 1200 LBS, U < 1280 LBS W/ (1) 3/4"• SIMPSON TITEN BOLT/J-BOLT, S" MIN.
<br />EMBED (22) 16d GALV. COMMON NAILS AND (8)16d GALV. COMMON NAILS.
<br />B - SIMPSON HUS28 G <2400 LBS, U < 1425 LBS W/ (2) 3/4- SIMPSON TITEN BOLT/J-BOLT, 5" MIN.
<br />EMBED (22) t6d GALV. COMMON NAILS AND (10) 16d GALV. COMMON NAILS.
<br />C - SIMPSON HGUS28-2 G <2400 LBS, U < 1810 LBS W/ (2) 3/4"' SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS.
<br />D - SIMPSON HGUS28-2 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4"' SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS.
<br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4- SIMPSON TITEN BOLT/J-BOLT, 5"
<br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS.
<br />WOOD LEDGER
<br />ATTACHMENT DETAIL
<br /># 1100 UPLIFT SIMPSON -
<br />HTSM20 W/1010d TO
<br />TRUSS AND (4)1/4" x 2 V4"
<br />TITEN 2 ANCHORS TO
<br />CONT POURED LINTEL
<br /># 1900 UPLIFT (2) SIMPSON
<br />HTSM201NSTALLED ON
<br />OPPOSITE FACES OF
<br />BLOCK WALL W/10 10d TO
<br />TRUSS AND (4) 1/4" x 2 1/4"
<br />TITEN 2 ANCHORS TO
<br />CONT POURED LINTEL
<br />PRE-ENG TRUSS
<br />CONTINUOUS BOND BEAM
<br />TITEN 2 ANCHORS MIN.
<br />2" COVER & 2' APART
<br />REPAIR OF MULTIPLE
<br />MISPLACED EMBEDDED TRUSS ANCHOR
<br />3 SCALE: 3/4"=1'-0"
<br />6'-0" MAX (W/1X4)
<br />OR 10'-0" MAX (W/2X4)
<br />1.4 DIAGONAL
<br />BTM. CHORD
<br />BRACING, SEE
<br />PLAN FOR LOCATION
<br />MAY NOT BE
<br />REQUIRED
<br />BTM. CHORD OF
<br />WOOD ROOF TRUSSES
<br />lx4 BTM. CHORD BRACING 6'-0" O/C —J END WALL OR OTHER
<br />MAX., OR 2x4 BTM, CHORD BRACING END TYPE CONDITION, IF
<br />10-0" O/C MAXSECURED W/ (2) 1Od DEPICTED SEE PLAN
<br />COMMON NAILS AT EACH CHORD /�
<br />INTERSECTION TYP. /1 BTM. CHORD BRACING
<br />SCALE: 3l4"=1'-0'
<br />6 EDGE
<br />CENTRAL
<br />SPACING
<br />SPACING
<br />SEE
<br />SEE TRUSS R OR TM.
<br />CHEDUL
<br />SCHEDULE SEE FRAWNGPLAN
<br />SEE SCHEDULE FOR BOLT SIZE
<br />SEE LEDGER SCHEDULE d
<br />51/2' MIN. EMBED. (TYP)
<br />1. ENSURE THAT EXP. BOLTS/J-BOLTS ARE
<br />PLACED INTO GROUTED CELLS, 8" ALL AROUND
<br />BOLT.
<br />- Z
<br />2. END OF FRONT AND REAR LEDGER SHOULD
<br />O1
<br />LAP A MIN OF 4'-0".
<br />3, ALL BOLTS TO HAVE WASHERS
<br />Z
<br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY
<br />CLOSER THAN 6' 0/C.
<br />5. IN LIEU OF HILTI PAPS SIMPSON TITEN 1/4"
<br />(2) _ PT
<br />DIA. x 3" MASONRY SCREWS MAYBE USED,
<br />SAME NT
<br />LEDGER SCHEDULE
<br />MARK
<br />SIZE
<br />BOLT SIZE
<br />BEDGESPACING
<br />CENTRAL8PACING
<br />A
<br />DOUBLE 2x8
<br />12"
<br />8" O/C
<br />16" O/C
<br />B
<br />DOUBLE 2x8
<br />3/4"
<br />8" O/C
<br />24" O/C
<br />C
<br />DOUBLE 2x10
<br />1/2"
<br />8" O/C
<br />16" O/C
<br />D
<br />DOUBLE 2x10
<br />3/4,
<br />8" O/C
<br />24" O/C
<br />E
<br />DOUBLE 2.10
<br />3/4"
<br />6" O/C
<br />16" OIC
<br />F
<br />DOUBLE 2x12
<br />3/4"
<br />10 WOOD LEDGER DETAIL
<br />SCALE: 3/4"=1'-0"
<br />(2) 2X4 No.2 SYP DIAG.
<br />2x4 BLOCKING BETWEEN
<br />BRACE W/ (3) 12d @ EA.
<br />TRUSSES WHERE
<br />TRUSS (DIAG. BRACE TO
<br />X-BRACING IS PRESENT AT
<br />COVER 5 TRUSSES)
<br />4'-0' O.C. (AT SHEATHING
<br />0'-0' TO 30'4" (1) "X" BRACE
<br />SEAMS)
<br />30'-1"TO 60'-0 (3) "X" BRACE
<br />SECURE 26 PT. PLATE
<br />(1) "X" BRACE @ CENTER
<br />TO BLK W/ 12" DIA.
<br />(2) "X" BRACE DIVIDED EQUALLY
<br />ANCHOR BOLT W/ Z'
<br />FROM CENTER TO END.
<br />WASHER SET IN HIGH
<br />2x WOOD FASCIA,
<br />STRENGTH EPDXY 6'
<br />SEE ARCHITECTURAL
<br />MIN. EMBED. AT 32" OC
<br />MAX.
<br />PRE-ENG GABLE TRUSS
<br />SECURE GABLE TO 2x8
<br />P.T. PLATE W/ 12d's 8"
<br />STIFFBACK (AS PER
<br />O.C. MAX
<br />TRUSS ENG)
<br />CONT, 2.4 SECURED W/
<br />(2) 10d's @ EACH TRUSS
<br />TO BE INSTALLED
<br />10'-0" O.C. MAX.
<br />SEE SCHEDULE FOR
<br />BOND BEAM REQ.
<br />BLOCK WALL W/ GABLE END
<br />PRE-ENG'D TRUSS SCALE:3/4"=''-a'
<br />THE USE OF ALTERNATE MATERIALS MAY BE
<br />USED SO LONG AS THEY CONFORM TO THE
<br />FOLLOWING
<br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS
<br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS
<br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (Fl AND F2) LOAD CAPACITIES
<br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND
<br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE
<br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO
<br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2
<br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE
<br />SUBJECT TO F1 AND F2 FORCES.
<br />ALTERNATE MATERIALS
<br />SCALE, 3/4"=T-0"
<br />A I C N I T I C T 8
<br />6
<br />Grou;LE.
<br />141 N. RONALD REAGAN BLV
<br />LONGWOOD, FL 32750
<br />PH: 407-774.6078
<br />FAX: 407-774-4078
<br />W W W.abdesigngroupxom
<br />AA #: 0003325
<br />DRAFTING BY:
<br />A.B. DESIGN GROUP
<br />DRAFTING INC.
<br />5439 BEAUMONT CENTER BLVD,
<br />SUITE 1004
<br />TAMPA, FLORIDA 33634
<br />PH: S134886-2628
<br />FAX: 813-886-2802 04
<br />9111111111!
<br />9VHDIv" ds LOT
<br />SILVERADO
<br />LOT #18
<br />BLK #10
<br />WE
<br />DETAILS
<br />A'mz'VT DATE 070921 / /
<br />9CAL.E: 1/4"=1'—O"
<br />SHEET
<br />S3.1A