My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6660 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6660 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:05 PM
Creation date
2/19/2025 12:29:12 PM
Metadata
Fields
Template:
Building Plans
Street #
6660
Location
Cobble Bliss St
Contractor
DR Horton
Building Plans - Permit #
2819
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9, ALL FIRE RATED CEILINGS AND WALLS °SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 607. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />COUNTERSUNK <br />C.O. PLUG <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/Ib'X2' TAPGONS� UNIT �SIMPSON WB ROLL STRAP FIN. GRADE <br />OR EQUAL <br />OR PAVING <br />4' CONCRETE SLAB � SECURE STRAP TO UNIT W/ (2) <br />"8XI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN CORD. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />CIA <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />1'-6' <br />r <br />EC. <br />CONC. <br />OR <br />ION TO SOIL <br />STE AS <br />ED <br />nEXT. GROUND CLEAN -OUT (TYPN) <br />NOTEa <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />f y <br />AIR RETURN <br />RUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM-1RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 7TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 301.2A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />BRASS PLUG <br />INSIDE <br />CAULK <br />FIN. FLOOR <br />OR WALL <br />FITTING OR EXTENS <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 560M <br />SERIES NICKEL BRASS TOP <br />P.V.0 OPTI/SPEC <br />OFLOOR SLAB CLEAN -OUT (TYP.TI <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4' • I'-0' <br />I E C N IT E C T Ii <br />Grou inn <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813S86-2628 <br />FAX: 813$86-2802 <br />aUSDIV. Se L07 <br />SILVERADO <br />LOT #17 <br />BLK #10 <br />PROJECT* <br />03719.001-17101 <br />MODET- <br />3278-JORDYN II <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />%150 PH a C <br />27 <br />DXj'j- 07/12/21 <br />aCALM: AS NOTED <br />SHEET <br />M1 <br />