Laserfiche WebLink
v <br />It <br />3/4' TIG SUM FLOOR <br />GLUED 4 SCREWED <br />PER FASTENER <br />IW-8 3/4' <br />SCHEDULE <br />2ND FIN. FLR <br />9'-4' BRG. HGT. <br />A <br />� <br />FLOORING <br />SYSTEM (SEE <br />FIRST FLOOR <br />FRAMING PLAN) <br />2x NW <br />OVER <br />2-8 DOOR AT <br />STORAGE <br />UNDER <br />STAIRS <br />STAIRS RISER5 TO OON OW <br />TO FBCR TTH EDITION 2020 <br />MIN TREAD-W' <br />MAX R16ER.1 3/4' 3/16' MAX <br />VARIATION IN RISERSRREADS <br />ADJACENT TO EACH OTHER <br />3/8' MAX VARIATION IN ANY <br />RISEW' AD HANDRAIL <br />CIRCULAR C11086 SECTION <br />OIA TO BE 1 W4' .-1/4' OR <br />PROVIDE EQUIVALENT <br />GRASPAMILITY UNDERS- MIN <br />6' WIDE • NARROW END MIN II' <br />WDTH • 17' EN FROM NARROW D <br />34' MIN HANDRAIL W.T. <br />0'-0' FIN. FLR <br />1STAIR SECTION <br />SCALE: IR' • I'-0' <br />WALL <br />THE CLEAR SPACE <br />BETWEEN THE <br />HANDRAIL ANC <br />THE WALL SHALL <br />BE 2-1/4 <br />HANDRAIL 6 36 <br />) LAYERS OF 3/4' PLYWOOD <br />OR (2) LAYERS OF 3/4' SUB <br />FLOOR MATERIAL RIPS FOR <br />SOLID NAILING <br />- SECURE TREADS TO STRINGER <br />W93) M Y SCREWS • EA <br />STRINGER WTWWADED SWANK <br />TO EXTEND MEYOND THICKNESS <br />OF SUM -FLOOR SHEATWING <br />NOTE: <br />HANDRAILS SHALL HAVE <br />EITHER A CIRCULAR CROSS <br />SECTION WITH A DIAMETER OF 1 <br />1/4'I: 2' OR A NONCIRCULAR <br />CROSS SECTION WITH A <br />PERIMETER DIMENSION OF AT <br />LEAST 4' BUT NOT MORE THAN <br />6 1/4' AND A LARGEST CROSS <br />SECTION DIMENSION NOT <br />EXCEEDING 2 1/4'. EDGES <br />SHALL HAVE A MINIMUM RADIUS <br />OF 1/8'. <br />HANDRAIL SECTION <br />A SCALE: NITS <br />NOTE: <br />-2-8 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-6 SOLID <br />DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. <br />-VERIFY CONDENSER PAD LOCATION WITH SITE PLAN <br />-OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE <br />EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) <br />IN THICKNESS, SOLID OR HONEYCOMB -CORE STEEL DOORS NOT <br />LESS THAN 1 3/8' (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. <br />-THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE 4 ITS <br />ATTIC AREA BY NOT LESS THAN 1,2'(12.1mm) GYPSUM BOARD APPLIED <br />TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS <br />SHALL BE SEPARATED FROM ALL HABITABLE ROOMS BY NOT LESS <br />THAN %Y&bnm) TYPE X GYPSUM BOARD OR EQUIVALENT. <br />-UNDER STAIR PROTECTION: <br />ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, <br />UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE <br />ENCLOSED SIDE WITH 1/2 INCH GYPSUM BOARDS. <br />FBCR 2020 OTH ED.) 3021 <br />9'-9. <br />ROOF BELOW <br />r-------------------------------------- i <br />I I <br />I I <br />I I <br />I I <br />ovin <br />ol!:l.:l:l:l:l:l:l:!lol!:!:!:!:!:l.:!:! <br />i� <br />• <br />�i <br />N10-Il�i�i�1�� <br />m...mmm11'��fi <br />Itl <br />�W. <br />0.4.11 <br />Meo d::d:ilIa10' ♦o <br />NXIaI :d�de'd.:.:::10 <br />olfd, <br />p, <br />A <br />•.� <br />4 <br />SECOND FLOOR PLAN <br />SCALE: I/4' • I'-0' <br />AECEITECT6 <br />GWon <br />LD <br />641 N. RONALD REAGAN BLV <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdwigngroup.com <br />AA C 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-886-2628 Of <br />FAX: 813.888-2802 <br />SILVERADO <br />LOT #17 <br />BLK #10 <br />PROJECT* <br />03719.001-17101 <br />MODEL <br />3278—JORDYN II <br />GARAGE OWING: <br />RIGHT <br />PAGE: <br />SECOND FLOOR <br />PLAN <br />15 H EXP. C <br />