My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6660 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6660 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:05 PM
Creation date
2/19/2025 12:29:12 PM
Metadata
Fields
Template:
Building Plans
Street #
6660
Location
Cobble Bliss St
Contractor
DR Horton
Building Plans - Permit #
2819
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYM. <br />DESCRIPTION <br />r6- <br />STANDARD SWITCH <br />-WAY SWITCH <br />-WAY SWITCH <br />ygDIMMER <br />SWITCH <br />H9 <br />PUSH BUTTON <br />ISCONNECT <br />T <br />WERMOSTAT <br />SINGLE RECEPTACLE (125v/20-AMP <br />INGLE POLE) <br />=0 <br />110V DUPLEX RECEPTACLE <br />=0 <br />10V DUPLEX RECEPTACLE (EQUIPPED <br />ITH GROUND FAULT <br />NTERUPTER/TAMPER RESISTANT TYPE) <br />IVV DUPLEX OUTLET (HALF OF OUTLET <br />WIRED TO SWITCH) <br />EXTERIOR WATERPROOF/GFI <br />RECEPTACLE (GROUND FAULT <br />NTERUPTER) <br />110V QUADPLEX RECEPTACLE <br />® <br />10V DUPLEX RECEPTACLE (FLOOR <br />OUNTED) <br />20V RECEPTACLE (4 WIRE <br />CTOR) <br />EDICATED RECEPTACLE <br />L MOUNTED LIGHT <br />EILING MOUNTED LIGHT <br />ANT LIGHT <br />LOOD LIGHT <br />L SCONCE PRE -WIRE <br />NT FAN WITH LIGHT (I CFM PER 50. FT.) <br />S_°9 <br />BULB LIGHT FIXTURE <br />no= <br />BULB LIGHT FIXTURE <br />BULB LIGHT FIXTURE <br />48' TRACK LIGHTING <br />ATTIC LIGHT WITH PULL CHAIN <br />LINDER CABINET LIGHT <br />® <br />'x4' FLUORESCENT LIGHT (RECESSED) <br />m <br />'x4' FLUORESCENT LIGHT (SURFACE <br />MOUNT) <br />2'x4' FLUORESCENT LIGHT (RECESSED) <br />ej <br />x <br />CO) <br />IRECESS, LIGHT <br />• <br />RECESS LIGHT (VAPOR PROOF) <br />FILING MOUNTED LIGHT WITH J-BOX <br />OR OPT. FAN <br />ELECTRICAL PANEL (FIELD VERIFY <br />LOCATION) <br />J-BOX (WALL MOUNTED) <br />Q <br />-BOX (CEILING MOUNTED) <br />FILING MOUNTED FAN <br />0 <br />NT FAN (1 -FM PER SQ, FT.) <br />PHONE JACK <br />1•Q <br />SMOKE DETECTOR (WALL MOUNTED) <br />Q <br />SMOKE DETECTOR (CEILING MOUNTED) <br />® <br />/ X D G OR <br />C I I MOUNTED) <br />HIMES <br />® <br />MOUNTED OR G <br />OPENER <br />TV <br />TV JACK <br />-� 8 PORT <br />• LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS <br />TO BE VERIFIED • HOMEOWNER <br />PRE -CONSTRUCTION MEETING. <br />• ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC <br />FAULT PROTECTED PER ELECTRICAL PROVISIONS <br />OF FBCR Ith EDITION (2020) 4 NEC 210.12 2011 <br />EDITION. <br />• 20 AMP DEDICATED LAUNDRY CIRCUIT. <br />• GPI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />• DISHWASHER DISCONNECT TO BE LOCKOUT IN <br />PANEL <br />• BATHROOM EXHAUST FAN TO NAVE MIN. CAPACITY <br />OF 50 CFM MTERMITTENT PER ELECTRICAL <br />PROVISIONS OF FB SECTION M15013 CR Ith <br />EDITION 12020). <br />• LAUNDRY ROOM RECEPTACLE SHALL BE GROUND <br />FAULT CIRCUIT -INTERRUPTER PROTECTION FOR <br />PERSONNEL ON FEEDERS <br />• WIRING METHOD SHALL BE NON METALLIC CABLE <br />PER ELECTRICAL PROVISIONS OF FBCR Ith ED <br />(2020). <br />• ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR ITH ED (2020). <br />• �_ LAMPS 8HALL BE SELECTED BY BUILDER <br />AND 15% OF LIGHTING MIDST BE ENERGY EFFICIENT <br />TYPE PER FJ5L. ENERGY CONSERVATION <br />(RESIDENTIAL ENERGY EFFICIENCY) 2020. 1th <br />�� Bo El COVERED <br />I I CASUAL v LANAI <br />I a I DINING <br />I 0 OPT. oPRE-WIRE <br />FOR <br />FFIINIIXTURE i CLGPAN <br />AN <br />I I i Wp ID <br />l 1 / . GF1 / -�i <br />__________/ <br />--------------� -f -L O <br />db <br />LED LIGHTING �\ \\ <br />C SINGLE LAV. Q------ �— BDRM 2 <br />BATH 2 PRE -WIRE <br />JUNCTION I -- FOR <br />BOX UUNDER \ ROOM CLG FAN <br />ELEC. FOR HOOD/ 1 �� <br />r MICRO ABV. I „'il FOR DJU. i ((�PRE-WIRE O <br />O 1 -- \ / N FOR N I <br />_------- yl F, i CLG FAN I <br />OPT. Io <br />I I I CAFE <br />I <br />LJ \ FIXTURE <br />BATH <br />------ KITCHEN �� \ 1 \\ / <br />oPT. <br />LED LIGHTING jREF F71,-- \ ` <br />® SINGLE LAV. `-- -- --- — ---\— \ <br />-- <br />I 1 I \ <br />POWDER RM `./� \\ <br />a I � I I I T N V \� POWDER <br />PANTRY L F I G Y1 <br />i�ml <br />Lail --- <br />�\ . - - -0 <br />FLEX \ CHIMES <br />0 GFI• / 1 GFI• <br />ROOM FOYER 44'AFF. ,� \\ 44'AFF. <br />II � <br />PF WIRE (� ATTIC ACCESS W/ �\ <br />FOR Y SWITCH 4 LIGHT \ <br />CLG FAN \ I - - \\ <br />\ I CFI• \ `� <br />\ / 44'AFF. \ L J <br />\\ SD V/CO, <br />\ O <br />--- � GFI CLG. � <br />GARAGE \ 1 <br />-- �. OUTLET \\ 1 I <br />IWP <br />P.B. FOR wl \ / <br />CHIMES L 1 I / <br />GPI GLG.($ <br />ENTRY I OUTLET <br />W0 <br />OUTLET FOR <br />IRRIGATION <br />000 \ TIMER <br />PRE -WIRE <br />FOR COACH \ <br />LIGHT \ <br />\Lsj O O O <br />PRE -WIRE ------- --- PRE -WIRE <br />FOR COACH FOR COACH <br />LIGHT LIGHT <br />FIRST FLOOR <br />ELECTRICAL PLAN <br />SCALE: I/4' • I'-0' <br />A R C N IT E C T R <br />Grouse <br />"I N. RONALD REAGAN BLV <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />w .abclmigngmupxom <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813S86-2628 <br />FAX: 813S862802 <br />�NII�I�I <br />sysDIv. de LOT: <br />SILVERADO <br />LOT #17 <br />BLK #10 <br />PROJECT# <br />03719.001-17101 <br />MODEL.• <br />3278-JORDYN II <br />GARAGE STI►INO: <br />RIGHT <br />PAGE: <br />1ST FLOOR <br />ELECTRICAL <br />PLAN <br />15YVPH IN. C <br />DATE: O7/12/21 <br />SCALE: AS NOTED <br />SHEET <br />EI <br />