Laserfiche WebLink
A{l) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(9) 10d x 1 }'NAILS TO TRUSS <br />B42) SIMPSON HETA16 TRUSS ANCHOR WITH <br />(12) 16d x 1 }" NAILS TO TRUSS <br />DBL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />C41) SIMPSON LGT2 GIRDER TIEDOWN WITH <br />(16) 1Od x 3 }'NAILS TO GIRDER AND <br />(2) SIMPSON HETA16 TRUSS ANCHORS <br />WITH (12) 16d x 3 J' NAILS TO GIRDER <br />lx2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED Wl (3) 16d <br />GALV. COMMON NAILS. <br />1x2 SECURED W/ 10d <br />GALV. COMMON NAILS <br />12" O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOFM/ALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE. A PT SYP #2 2" x 4", <br />5', W x 4'-0" MAY BE ADDED <br />W/ 10d NAILS, 2 ROWS, 3" <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE TRUSS <br />ANCHOR REQUIREMENTS. <br />ENGINEERED WOOD <br />TRUSSES @ 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />ANDAPPROVAL <br />A ALLOWABLE UPLIFT = U:1810 LBS, L770 LBS (1 PLY) <br />B ALLOWABLE UPLIFT = U.2365 LBS, L:1430 LBS (2 OR 3 PLY) <br />C ALLOWABLE UPLIFT = U.2705 LBS (2 PLY) <br />SS&1CIGIRDER1ATYPICAL TRUSS/ <br />I" CONNECTOR(S) SCAL <br />SERIES <br />BACKERBLOCR <br />THICKNM <br />4500 <br />3/4" WOOD PANELS <br />6000 <br />(2) 1/7' WOOD PANELS <br />60 <br />(2) 1/7' WOOD PANELS <br />90 <br />2x LUMBER <br />3/4" T & G SUBFLOOR GLUED AND <br />SCREWED AS PER SCHEDULE <br />PRE-ENG IJOIST <br />518" GYPSUM BOARD OR 1/2' HIGH <br />STRENGTH CLG. BOARD <br />SECURE IJOIST TO TOP PLATE <br />W/ (2) 12d TOENAILS <br />DOUBLE TOP PLATE <br />2x4 OR 2x6 WOOD BEARING <br />WALL W/ SYP No 2 STUDS SEE <br />PLANS FOR SPACING. SINGLE <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />1/2" GYP. WL BD. <br />SEE SHEET SlAA FOR <br />NAIL SIZE AND PATTERN <br />r, _ IWOIST CONNECTION @ L.B.W. <br />`+ scALE:-"="-a' (NO UPLIFT) <br />OUTER 1/3 OF <br />SPAN ONLY <br />BTM,_ <br />PLATE <br />DEPTH 1/4'D <br />—HOLE EDGE >5/8" <br />-HOLE DIAMETER <br />215*0 SGL. STUD <br />HOLE EDGE >5/8" <br />01 <br />HOLE DIAMETER <br />< 3/5•D DBL STUD <br />STUD NOTCHING <br />AND BORING LIMITS <br />ENGINEERED WOOD TRU <br />24" O/C, SUBMIT SHOP <br />DRAWINGS FOR REVIEW <br />AND APPROVAL <br />(1) SIMPSON HETA16 —. <br />TRUSS ANCHOR WITH <br />(9)10d x 1 }'NAILS TO <br />GIRDER, PROVIDE 5" <br />MINIMUM CONCRETE <br />EMBEDMENT. USED IN <br />CONJUNCTION WITH <br />HEAVY UPLIFT <br />CONNECTOR <br />PLYWOOD SHEATHING, SEE <br />"ROOFNVALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE" <br />NOTE: APT SYP #22"x4", <br />6", Tx 4LO" MAY BE ADDED <br />W/ 1Od NAILS, 2 ROWS, W <br />O/C TO FACILITATE ONE <br />ADDITIONAL PLY MAX. TO <br />ACCOMMODATE GIRDER <br />TIEDOWN REQUIREMENTS. <br />LGT D TIEDOWN <br />GIRCMU <br />TWIT <br />TO AN <br />WITH (4) �" x 5" TITEN HD TO CMU AND (12) SDS <br />(4) J' x " N <br />}" x 2 J" TO GIRDER <br />B41) SIMPSON FGTR GIRDER TIEDOWN WITH <br />(2) �' x 5" TITEN HD TO CMU AND (18) SDS �' x <br />lx2, 2x WOOD FASCIA <br />3" TO GIRDER <br />SEE ARCHITECTURAL <br />C42) SIMPSON FGTR GIRDER TIEDOWNS WITH <br />2x SECURED W/ (3) 16d <br />(2)}" x 671TEN HD TO CMU AND (18) SDS �' x 3" <br />GALV. COMMON NAILS. <br />ix2 SECURED W/ 10d MASONRY BOND <br />SCREWS TO GIRDER (EACH TIEDOWN) <br />GALV. COMMON NAILS BEAM <br />ENSURE THAT CELLS ARE GROUTED <br />17, O/C SEE SCHEDULE <br />SOLID, W EACH WAY OF BOLTS <br />A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) <br />B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) <br />C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) <br />2A 2B 2C TYPICAL ROOF <br />GIRDER CONNECTOR(S) 'ALE <br />SEREB <br />Ilwamm <br />TH WESS <br />4500 <br />3/4" WOOD PANELS <br />8000 <br />(2) V2" WOOD PANELS <br />80 <br />(2) 112" WOOD PANELS <br />90 <br />2x LUMBER <br />LSTA12 20 GAUGE <br />Aldx1/2 <br />W/ HDG COMMON NAILS, EACH END TOTAL OF 10 <br />LVUIJOIST WITH <br />BACKER BLOCK <br />HTT4 W/ 5/8" A.B. WITH <br />MIN, 7" EMBEDMENT <br />TO SLAB & (18)16d x <br />2-lrZ' NAILS TO POST., <br />POST TO SIT DIRECTLY <br />ON SLAB <br />4• <br />LVL/WOOD POST CONNECTIONS <br />5 <br />NOTE: <br />T_-WHEN TRUSS BEAR ON TOP OF LEDGER USE SIMPSON HTS20 FROM <br />A - SIMPSON HUS28 G < 1200 LBS, U < 1280 LBS W/ (1) 3/4— SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22)16d GALV. COMMON NAILS AND (8)16d GALV. COMMON NAILS. <br />B - SIMPSON HUS28 G <2400 LBS, U < 1425 LBS W/ (2) 3/4' SIMPSON TITEN BOLT/J-BOLT, 5" MIN. <br />EMBED (22) 16d GALV. COMMON NAILS AND (10)16d GALV. COMMON NAILS. <br />C - SIMPSON HGUS28-2 G 12400 LBS, U < 1810 LBS W/ (2) 3/4"° SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />D - SIMPSON HGUS28-2 G <4800 LBS, U < 1810 LBS W/ (4) 3/4"' SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />E - SIMPSON HGUS28-3 G < 4800 LBS, U < 1810 LBS W/ (4) 3/4- SIMPSON TITEN BOLT/J-BOLT, 5" <br />MIN. EMBED (36) 16d GALV. COMMON NAILS AND (12) 16d GALV. COMMON NAILS. <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: 3/4"=V-0' <br /># 1100 UPLIFT SIMPSON <br />HTSM20 W/10 10d TO <br />TRUSS AND (4) 1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br /># 1900 UPLIFT (2) SIMPSON <br />HTSM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/10 iOd TO <br />TRUSS AND (4) 1/4" x 2 1/4" <br />TITEN 2 ANCHORS TO <br />CONT POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />�— TITEN 2 ANCHORS MIN. <br />2" COVER & Z' APART <br />REPAIR OF MULTIPLE <br />MISPLACED EMBEDDED TRUSS ANCHOR <br />3 SCALE: 3/4"=1'-0' <br />6'-0" MAX (W/1X4) <br />OR 10'-0" MAX (W/2X4)* <br />lx4 DIAGONAL <br />BTM.CHORD <br />BRACING, SEE <br />PLAN FOR LOCATION <br />MAY NOT BE <br />REQUIRED <br />BTM. CHORD OF <br />WOOD ROOF TRUSSES <br />lx4 BTM. CHORD BRACING V-0" O/C SEND WALL OR OTHER <br />MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF <br />1 U-9, O/C MAXSECURED W/(2)1Od DEPICTED SEE PLAN <br />COMMON NAILS AT EACH CHORD /� /. <br />INTERSECTION TYP. BTM. CHORD BRACING <br />6 SCALE: 3/4"=1'-0" <br />5'EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE USES BA . ORG. R BTM. <br />CHEDUL <br />SCHEDULE SEE FRAMING PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />SEE LEDGER SCHEDULE W <br />51/7' MIN. EMBED. (TYP) <br />1, ENSURE THAT EXP. BOLTS/J-BOLTS ARE <br />PLACED INTO GROUTED CELLS, 8" ALL AROUND <br />BOLT. <br />Z <br />2. END OF FRONT AND REAR LEDGER SHOULD <br />m g <br />LAP A MIN OF 4'-0", <br />3. ALL BOLTS TO HAVE WASHERS <br />Z <br />4, EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />°J <br />CLOSER THAN 6" O/C. <br />5. IN LIEU OF HILTI PAPS SIMPSON TITEN 1/4" <br />(2) _ PT <br />DIA. x 3" MASONRY SCREWS MAY BE USED, <br />BAMF CPA(:ING RFDI IIRFMPNT <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />SEDGESPACING <br />CENTRALSPACINO <br />A <br />DOUBLE 2z8 <br />1/2" <br />8" O/C <br />16" O/C <br />B <br />DOUBLE 2xB <br />314' <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 2x10 <br />1/2' <br />8" O/C <br />16" O/C <br />D <br />DOUBLE 2xl0 <br />3/4' <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 2x10 <br />3/4" <br />6" O/C <br />16" O/C <br />F <br />DOUBLE 2x12 <br />3/4" <br />6" O/C <br />12" O/C <br />10 WOOD LEDGER DETAIL <br />SCALE: 3/4"=1'-0" <br />(2) 2X4 No.2 SYP DIAG. <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3) 12d C EA. <br />TRUSSES WHERE <br />TRUSS (DIAG. BRACE TO <br />X-SRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4'1" O.C. (AT SHEATHING <br />0'-0" TO 30'-0" (1) "X" BRACE <br />SEAMS) <br />30'-l" TO 60'-0 (3) "X" BRACE <br />SECURE 2x8 PT. PLATE <br />(1) "X" BRACE 0 CENTER <br />TO BLK W/ 1/2" DIA. <br />(2) "X" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/ 7' <br />FROM CENTER TO END. <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 6" <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 32" OC <br />MAX. <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />P.T. PLATE W/ 12d's 8" <br />STIFFBACK (AS PER <br />O.C. MAX ' <br />TRUSS ENG) <br />CONT. 2x4 SECURED W/ <br />(2) 10d'. C EACH TRUSS <br />TO BE INSTALLED @ <br />10'-0" O.C. MAX. <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />BLOCK WALL W/ GABLE END <br />PRE-ENG'D TRUSS SCALE 3/4"=1'-0 <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 <br />FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO F1 AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />SCALE <br />A R C N I T E C T <br />Gro sp0i . <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 813-806-2802 <br />