My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6698 Cobble Bliss St
Zephyrhills
>
Building Department
>
Building Plans
>
6698 Cobble Bliss St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 11:52:54 AM
Creation date
2/19/2025 12:26:42 PM
Metadata
Fields
Template:
Building Plans
Street #
6698
Location
Cobble Bliss St
Contractor
DR Horton
Building Plans - Permit #
2650
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFa. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON-CONOITIONED AREAS $HALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC, AND <br />INSTALLED AS PER FBC ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA 90A 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ISECURE STRAP <br />W/ (2)-3/16'X2' <br />COUNTERSUNK <br />CD. PLUG <br />i0 <br />CONDENSER FIN. GRADE <br />UNIT SIMPSON WB ROLL STRAP OR PAVING <br />�OR EQUAL <br />4' CONCRETE SLAB-/ `SECURE STRAP TO UNIT W/ (2) <br />"8X1 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />M <br />PASS-THRU AIR GRILL <br />SEE SPEC. <br />I'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />CONNECTION TO PAD 1 E <br />517E PLAN <br />NOTE: MAIN 0 12' DRAIN RU OEXT. GROUND CLEAN -OUT (TYP <br />OVER HEAD 12FROM STRUCTURE <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />SCORIATED NICKEL <br />FIN. FLOOR <br />O O <br />EXTERIOR WALL <br />BRONZE FL. PL. <br />OR WALL <br />PLENUM <br />p y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />BRAGS PLUG <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />FITTING OR EXTENSION TO <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SOIL OR WASTE AS <br />REQUIRED <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />WADE W40-K JOSAM 56000 <br />T <br />REFRIGERANT LINES TO <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />CAULK <br />P.V.0 OPTI/SPEC <br />TRAP DRAIN LINE AND TERMINATE <br />EVIN AN APROVED DRAIN, AS PER <br />FBCR ITH EDITION (2020) <br />INV. SEE <br />MECHANICAL BLDG. CODE <br />Y5ITE PLAN <br />SECTION 3013.4 <br />HVAC <br />DRAINS <br />FLOOR SLAB <br />CLEAN -OUT (TYPN) <br />�I <br />BDRM 2 <br />co <br />mME <br />I Ir I <br />L J <br />GARAGE <br />I <br />CASUAL <br />COVERED <br />DINING <br />I <br />LANAI <br />I <br />I o <br />I <br />00 ------ — ----- <br />8 <br />I <br />I <br />KITCHEN <br />I <br />I <br />I <br />GREAT <br />In <br />F--- <br />ROOM <br />--- <br />00 <br />I <br />I <br />II <br />O <br />II m. <br />LI n <br />I <br />I <br />14x11 <br />I <br />8 <br />x <br />N <br />10x10 <br />I <br />12' S/A <br />-- ---- <br />f <br />3 FROM <br />g <br />— ABOVE <br />---- <br />- ----- <br />( <br />I <br />I I I <br />-- <br />4 8x4 <br />I <br />I I I <br />I <br />PANTRY <br />o <br />x <br />x <br />FOYER <br />FLEX <br />ROOM <br />I0' S/A <br />FROM <br />ABOVE <br />I <br />ENTRY <br />I <br />ENTRY <br />_-------�---------------- <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4' • 1'-9)' <br />A N C N I T E C T t <br />6 <br />[�rDeS�lt <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.eom <br />AA #: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-866.2628 <br />FAX: 813486.2802 <br />��.W0000e�. <br />avHDIV. & LOT: <br />SILVERADO <br />LOT #14 <br />BLK #10 <br />Pl%0JECT# <br />03719.001-14101 <br />MODEL• <br />3278—JORDYN II <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />150 MPH . C <br />RINT <br />R <br />7/09/21 <br />S NOTED <br />1 <br />