Laserfiche WebLink
n <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE PLASHING OVER <br />TOP, SIOE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEd ESICE OF PLASHING. TO BE, <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />i <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />. <br />IAPPLY SEALANT AT PER91ETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE Yi CAULKING • JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R703.7 <br />EAWIdr IBBNtV and plastaitlp <br />BACKER ROD <br />I <br />Exterior use of pordand cement plaster <br />shall comply with the application <br />;X <br />requirements of ASTM C 926-12A. <br />rxI <br />Installation of exterior lathing and framing <br />rr; <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 9, <br />.�". <br />STUCCO WRAP <br />:X' <br />HOODED VENT <br />i' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING. PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD — <br />CONSTUCTION <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />WRS LAYER 4, FORTIP15ER <br />BUILDING PAPER <br />6' WIDE STRIP SELF <br />A01,E6IVE PLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z HASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIF15ER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R'103.1.1 / ASTM C-64.1-09, MIN. 2.5 LBS, <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />(V SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT w <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK) <br />ROOD CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER '2, FORTIF15ER <br />BUILDING PAPER <br />3 COAT CEMENT <br />Y6' TO Yo' MID -WALL <br />WEEP SCREED <br />�-6' SELF-ADHESIVE <br />FLASHING <br />BUILDING PAPER <br />WOOD FRAMED <br />OVER CIUICK <br />FLASH • r — — — 7 <br />WALL <br />HORIZONTAL WEEP SCREED <br />FRAME TO FRAME <br />rHRouGH <br />WALL <br />1 <br />6' SELF ADFESIVE <br />FLASHING (INSTALL <br />PER MANUF. SPECS) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />HRCCfi IrJ IiCC.CIVC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />-ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />I —­- '2R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARSER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 9, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />NOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FA <br />EDGE <br />APPLY E-Z <br />OVER 6m MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />too <br />Mae� <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />W IS LAYER 4, FORTIRBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MMISER • T' ON:. MAX <br />16' TO 1{' dIQ�110LL <br />W WIDE STRIP SELF <br />ADI-ESFVE PLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WRB LAYER 81, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />9 <br />STEP #1 <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />ING OVE FLASHR <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />S' <br />STEP #2 <br />WRB LAYER 9, <br />STUCCO WRAP <br />MEMBRANE FLASHING. <br />WRB LAYER'4, FORTIF15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #5 STEP #6 <br />(�) ELECTRICAL RECEPTACLE <br />A R C N I T E 6 T• <br />6 <br />Groin <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX; 407-774-4078 <br />www.abdosi@M"up.com <br />AA M: 0003325 <br />DRAFTING SY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SURE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813888.2628 <br />FAX: 613 386-2802 <br />levee° <br />. <br />OLMDZV. Ae L01`- <br />SILVERADO <br />LOT #13 <br />BLK #10 <br />03719.000-13101 <br />MIDIDIM, <br />GARAOR swnak <br />RIGHT <br />pwa WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />PlUNT D 8/03/20 <br />ECAXJn 1/4"-a.'-O" <br />WA2 <br />