My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6755 Ezra Loft Pl
Zephyrhills
>
Building Department
>
Building Plans
>
6755 Ezra Loft Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:56:34 PM
Creation date
2/19/2025 11:52:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6755
Location
Ezra Loft Pl
Contractor
DR Horton
Building Plans - Permit #
19234
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB / MASTIC. AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBCR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />a ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO !" G. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS, <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />001 <br />EXTERIOR WALL <br />PLENUM 1 <br />TTGERANT <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLYAUMECHANICAL <br />LINES <br />AIR HANDLERRIOR <br />WALL <br />VC CONDENSATE DRAIN LINE <br />EVAP.TRAYLEEVE <br />TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORMCONDENSING <br />UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (20I4) <br />BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />FIN. FLOOR <br />BRONZE FL. PL. <br />OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />501L OR WASTE AS <br />REQUIRED <br />- WADE 5240-K JOSAM 56000 <br />INSIDE I I SERIES NICKEL BRASS TOP <br />CAULK 1 I P.V,C OPTI/SPEC <br />Y <br />- ------ -_v [Ny.SEE <br />SIT`I' E PLAN <br />FLOOR SLAB CLEAN —OUT (T <br />NTF <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR i WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />-- <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO GONG. CONDENSER <br />W/ (2)-3/I6'X2' TAPCON5 UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB °SECURE STRAP TO UNIT W/ (2) <br />-5XI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUW <br />CA. PLUG <br />I .6. <br />SEE SPEC. <br />FIN. GRADE �I� <br />OR PAVING f <br />-��FITTING OR <br />I I EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I I <br />I� � II INv.9EE <br />NEXT. GROUND CLEAN —OUT (TYPN <br />FIRST FLOOR MECHANICAL PLAN <br />PROGRESSIVE AIR SYSTEMS 05/20/14 <br />A R C N I T R C T 8 <br />6 <br />Desion <br />Group"hr. <br />41 N. RONALD RFAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AA lh 0003325 J <br />w <br />2 <br />h <br />w <br />y <br />x <br />0 <br />h <br />W <br />0 <br />SLTHDIP. a LOT <br />,11 <br />SILVERADO <br />LOT 45 <br />BLK 6 <br />PROJECT/ <br />04128.000-04561 <br />MODEL: <br />4EBB <br />"1828-CALI" <br />GARAGE SwMG: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />AACIRECT. <br />STATE OF FLOfVDA <br />1 <br />� I 10/19/17 <br />SCALE: 1/4"=1'-0" <br />921MET <br />