My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6779 Eza Loft Pl
Zephyrhills
>
Building Department
>
Building Plans
>
6779 Eza Loft Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:06:10 AM
Creation date
2/19/2025 11:56:28 AM
Metadata
Fields
Template:
Building Plans
Street #
6779
Location
Ezra Loft Pl
Contractor
DR Horton
Building Plans - Permit #
19371
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />SYMBOL <br />DEFINITION <br />NOTES <br />y—y <br />125V CUTLET <br />mar 6NTLLE POLE <br />IIOv CUTLET <br />IIOV CURET <br />Q R MT04 WRED <br />NTO <br />6tlITCi1 <br />GFI <br />IIOV CUTLET <br />E016PED NTr(Ta'?D FAIL <br />Ressl) <br />EDBTAw Nf TTPE) <br />22CV OUTLET <br />(4) WRE C:ONERk1N <br />2II� <br />cfl <br />�_ET. YATfaRTlOLF <br />AO FALL <br />GROIFlrelEErleR, <br />SWTCH <br />9WTCH <br />3•UWT OPER <br />$4 <br />SWITCH <br />4-WAY OPER <br />F.%0 <br />HALL PIOU4IED <br />r v <br />L101R <br />CELn4G LKTFIT <br />\ �' <br />VAPM PROOF <br />10 <br />K <br />\Q\ <br />Fm=wED CAN <br />UALL 9CbFY'L <br />F'IE-uRiED <br />eV6Nf. <br />FAN <br />I CRI PER 60. FT. <br />VANT. FAN <br />TLLIOM <br />I CFM FER 6Q Fi. <br />1 <br />1rC/TT(\T <br />v <br />FUtN9S <br />tePEc•e TDD er <br />2-DULD FAT.6P <br />�� <br />FLUC'�BC84T <br />ARoua <br />)_ _ � <br />r RuoRl:acENr <br />4' ILUOR WNC <br />�r-� <br />IlIl©IlIl <br />4' 1RAGK LMwR <br />PANEL <br />TEETER <br />O5D. <br />81'KTO= DETECTOR <br />BD. <br />WALL FGUOED <br />Mt010: DETECTOR <br />IBATT. eme-In <br />uv Ne®11� <br />® S/CO I enQQ' DerzcTae � eOER.cvrEelED <br />BHrYL SE A DDTANOE <br />IS" TH N 4' <br />POIDArtr L16HT <br />r1/ <br />o�jNLT TT 6'AB <br />11.41 <br />pl TER � R <br />TO DE ELEyaI® <br />AM GOIIOT <br />DIBCRNECT <br />ON. <br />TELEVLNGNJAOC <br />CELL REdI <br />x elaPORTeD N <br />O70 <br />J <br />�-DOX <br />ACCORDANCE uv Sox <br />y� Ice,LOre FANnIONrIMA1��.D �51I0I F�01! <br />ROW LKM <br />OFT. SECURRY <br />IQTPAD <br />PD. FVBN-DUftON FOR QIFEB <br />•-�"� WD PORT <br />LOCATION OF TV JACKS 4 PHONE OUTLETS <br />FANS TO BE VERIFIED • HOMEOWNER <br />PRE -CONSTRUCTION MEETING. <br />ALL RECEPTACLES IN ALL HABITABLE <br />ROOMS TO BE ARC FAULT PROTECTED PER <br />ELECTRICAL PROVISIONS OF FBCR 5TH <br />EDITION (2014). <br />20 AMP DEDICATED LAUNDRY CIRCUIT. <br />GFI • ISLAND (NOT ON KITCHEN CIRCUIT) <br />DISHWASHER DISCONNECT TO BE LOCKOUT <br />IN PANEL <br />BATHROOM EXHAUST FAN TO HAVE MIN. <br />CAPACITY OF 50 CFM INTERMITTENT PER <br />ELECTRICAL PROVISIONS OF SECTION <br />M5013 FBCR 5TH EDITION (2014). <br />LAUNDRY ROOM RECEPTACLE SHALL BE <br />GROUND FAULT CIRCUIT-INTERMIPTER <br />PROTECTION FOR PERSONNEL ON FEEDERS <br />WIRING METHOD SHALL BE NON METALLIC <br />CABLE PER ELECTRICAL PROVISIONS OF <br />FBCR 5TH ED (2014). <br />ALL WORK TO COMPLY WITH ELECTRICAL <br />PROVISIONS OF THE FBCR 5714 ED (2014). <br />ALL LAI'IP9 SHALL BE SELECTED BY <br />BUILDER AND 15% OF LICxNTING MUST BE <br />ENERGY EFFICIENT TYPE F'ER FBC.. ENERGY <br />CONSERVATION (RESIDENTIAL ENERGY <br />EFFICIENCY) 2014. 5th EDITION R404J <br />PRE -WIRED <br />CLG FAN <br />BEDROOM !F2 \\ <br />\ <br />I <br />CONp, BOLLARD <br />O AS REQ. <br />PER BLDG. <br />- CODE <br />METER <br />FIELD <br />VERIFY <br />LOC. <br />IRRIGATION <br />OUTLET D <br />48' AFF. <br />�@GFI <br />PATIO <br />I <br />I e <br />Roo <br />j ROOMG <br />�-WIRED I <br />CLG FAN 1 <br />I \ <br />-- <br />/ / \ SWITCH IN 30 <br />CABINET <br />\ TO ZND FL. OUTLET \ FOR DWIN <br />Y/ <br />O Epz <br />TCH \ C <br />KITCHEN <br />TbGFI/ / ___1 <br />P.B. FGE �\ � � f <br />PAN- <br />DOOR S/CO 6FI <br />I / - - L --= I <br />I <br />/ <br />KEYLESS <br />FIXTURE <br />GFI <br />GARAGE <br />DOOR <br />PREWIRE <br />GARAGE <br />l/�L--------------------- <br />`COACH <br />L IGHT <br />� 7- <br />III <br />III \ PRE-WIRRED <br />\ CLG FAN <br />\ III \\ <br />3:� <br />\ III <br />\ III FLEX <br />FOYER \ III <br />1 III <br />I III <br />P8. FORS <br />// � CHIMES I <br />PORCH / <br />----- \—_--- /-----,-� <br />FIRST FLOOR ELECTRICAL PLAN <br />-OUTLET <br />FOR VENT <br />OR MICRO <br />I UNIT - NEW CHART <br />LOAD CALCULATIONS ONE FAMILY <br />DWELLING WITH HEAT PUMP <br />OF.0 CODE 92) <br />HOUSE PLAN: 4EHB HAYDEN MODEL <br />LOAD INFORMATION <br />VA <br />W05 SQ TT GENERAL LLOLTTDLO E S VA PER SOW <br />Ta16 <br />2 = Alai AFFLANCE CaCDR AT 1600 VA CA <br />5000 <br />I WIINDRY CaiCVR <br />1600 <br />I RANGE AT HAIR PLATE L Wn OR COODTOP/OVEN <br />1=n <br />I VAT IWAT <br />4600 <br />I D19NRA6RER <br />1200 <br />CWTTIF9 DRYER <br />6000 <br />L wsroaAt <br />bob <br />I IamovAVE <br />160D <br />1 REFRIGERATOR <br />1200 <br />9UBT'OTAL OP OENCRAL WAD <br />35218 <br />FfliBT IO RVA OF O@IALIL WAD AT 100% <br />I0000 <br />RSYAm OF OffiIRiA3. LOAD AT 401E 28236 VA z .4 <br />.288 <br />TOTAL Nee GENERAL LOAD <br />MW <br />&8 TON mAT PUIB (N/ 51(1I O®t m" BEAT 9TIaP) <br />m AID' i 240 VA- <br />_-- <br />&5 TON COOLING 8Y3iTE11 40 AW x 240 V <br />• 9800 <br />NET GENAtAL WAD <br />ft— <br />NET TarwL flvwc <br />Ono <br />TOTAL WAD <br />5o6e6 <br />CALCULATED LOAD FOR SERVICE <br />s9866 VA/240 V- ]20 wle <br />150 AMP SERVICE <br />'w_ CASE _Ar_ - HIGHEST fltlAC WAD <br />U&ID }YIR CALCINATION&• <br />NEUTRAL CALCULATION: <br />LIGHTING, APLLIANCE, LAUNDRY LOADS: 14,283 VA <br />3000 VA D 100%, REMAINDER D 35% <br />NET LOAD: 6,94E VA <br />RANGE: 120M 010% 5,400 VA <br />DRYER: 5,000 D 10 % 355��yA <br />TOTAL 18,849 VA <br />NEUTRAL AMPACITY: 18,489 / 240 . 18 A <br />02 AL MINIMUM NEUTRAL CONDUCTOR <br />PROVIDE 362/0 CU, THIILN . I'6 CU IN 2' CONDUIT OR 3 <br />�4/0 AL, THIN . Ift CU IN 2' CONDUIT. <br />(CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANGJ <br />150 AMP ELECTRICAL RISER <br />NOT TO SCALE. COMBINATION SERVICE 150 AMP <br />DISCONNECT SWITCH AND 120/240 VOLT <br />GENERAL NOTES; M ELECTRIC METER IN 1 PHASE <br />A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL NEMA 3R ENCLOSURE PANEL <br />COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). LOCAL CODES, AND ALL LOCAL POWER <br />COMPANY REQUIREMENTS. --A <br />B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS <br />NOTED OTHERWISE. <br />POWER C0MFA <br />TRANSFORMER <br />GRADE <br />PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - <br />ELECTRICAL SERVICE. PROVIDE 3 -1 COPPER (CU) IN <br />1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 <br />62/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC <br />CONDUIT UNLESS SERVICE IS PROVIDED BY THE <br />ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC <br />COMPANY PRIOR TO BID, <br />TELEPHONE SERVICE CABLE TELEVISION <br />ENTRANCE SERVICE ENTRANCE <br />EQUIPMENT EQUIPMENT <br />INTERSYSTEM BONDING <br />TERMINAL AT LOW <br />VOLTAGE CONNECTIONS <br />1 F4 CU SERVICE GROUND CONNECTED TO <br />CONCRETE ENCASED FOOTER STEEL PER <br />ELECTRICAL PROVISIONS OF THE FBCR 5TH <br />EDITION (2014). <br />5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD <br />A R C H I T E C T S <br />6 <br />GWOmm i;;n <br />-nc. <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407-7748078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />W <br />x <br />4 <br />W <br />O <br />c <br />R <br />aysDsv a Xil <br />SILVERADO <br />LOT 47 <br />BLK 6 <br />PMJMT# <br />04128.000-04761 <br />1[ODTEis <br />4EHB <br />112605-HAYDENII <br />GAE11 ss award: <br />LEFT <br />P FIRST <br />FLOOR <br />ELECTRICAL <br />PLAN <br />150 MPH EXP. B <br />DATM 10/20/17 <br />ai 1/4"=1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.