• s e u� r e e r e <br />HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS QHALL, BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBCR 5TH EDITION (2014) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 161 CLASS I AIR DUCT AS PER NFPA SOA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL, <br />OR OTHER MATERIALS AS PER FBCR 5TH EDITION (2014) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBGR 5TH EDITION <br />(2014) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBCR 5TH EDITION (2014) MECHANICAL CODE <br />SECTION 403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBCR 5TH <br />EDITION (2014) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL, <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />c..u�nvcs� <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />- y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 5TH EDITION (2014) <br />MECHANICAL BLDG. CODE <br />SECTION 30�2.1.1 <br />HVAC <br />DRAINS <br />SCORIATED NI^"�' <br />BRONZE F <br />BRASS <br />FIN. FLOOR <br />OR WALL <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 5,6000 <br />SERIES NICKEL BRASS TOP <br />RV.0 OPTI/SPEC <br />Iv. SEE - <br />aITE PLAN <br />OFLOOR SLAB CLEAN -OUT (TYP. <br />N <br />PATIO <br />LIVING <br />ROVM <br />DIN�NG <br />8' $/A RO M <br />FROM <br />ABOVEI <br />BEDROOM�#2 <br />II <br />12X8 I ------ <br />----------I------- <br />I I <br />I <br />(Ili <br />---------- <br />12XI2 <br />nI3 <br />BATH #2 <br />i® <br />PASS I I <br />THRU II <br />I� <br />i t I I <br />I <br />50 X� <br />---- ---------- <br />I I I I <br />—_—_—_------ <br />I <br />I L KITCHEN <br />O <br />MR. <br />I <br />rPAN.---'�I <br />8X4 I2Xg <br />8' S/A <br />FROM <br />III i' <br />ABOVE <br />��9X9 Ilj / <br />I <br />I I <br />III FLEX <br />FOYER <br />III <br />III <br />GARAGE <br />— — — <br />PORCH <br />O <br />O <br />FIRST FLOOR MECHANICAL PLAN <br />COUNTERSUNK <br />G.O. PLUG <br />SEE SPEC. <br />-----�?---------- <br />;_— I'-8'XS' CONC. <br />FIN. GRADE _ <br />OR PAVING — \. <br />— `FITTING OR <br />I I EXTENSION TO SOIL <br />_ L OR WASTE AS <br />REQUIRED <br />I I <br />J I <br />—— — — — — — - SITE ,SIT SEE <br />� PLAN <br />NEXT. GROUND CLEAN -OUT CLEAN-OUT(TYPN <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />'8XI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO P <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRICTURE <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />-- <br />BROKEN LINE- RETURN TRUW< <br />1 <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />THERMOSTAT <br />m <br />PASS-THRI AIR GRILL <br />6 <br />G�soign <br />rou1ri'�nc. <br />L441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774,4078 <br />www.abdeslgngroup.com <br />AA M. 0003325 <br />w <br />y <br />w <br />0 <br />a <br />R <br />aUDDIV. & L07 <br />SILVERADO <br />LOT 47 <br />BLK 6 <br />PROJMT# <br />04128.000-04761 <br />MODRIa <br />4EHB <br />"2605— HAYDEN" <br />GARAGL SIIIIRG: <br />LEFT <br />PAGR: <br />FIRST <br />FLOOR <br />ECHANICAL <br />PLAN <br />150 MPH EXP. B <br />r, ARCIiTECT= 1 <br />DP �T 10/20/17 <br />=JU 1/4"=1'-0" <br />61130 T <br />10 <br />