Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING+ TO BE: <br />I. BOTTOM, 2. SIDES, 3. TOP <br />I':: <br />X: VENT GAP 19 TO BE SET IN BED <br />._. <br />X: OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />I I <br />YXY JOINTS AND INTERSECTION5 <br />I- APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />( <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,)'4* CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior lathing and plastering <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />"X. <br />requirements of ASTM C 92' 12A. <br />j <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER M, <br />i� <br />STUCCO WRAP <br />;j <br />HOODED VENT <br />d' THICK 3 COAT CEMENT <br />-. <br />PLASTER <br />METAL LATH <br />WRB LAYER *2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING: <br />G A DRYER <br />VENT ( FRAME) <br />WOOD SHEATI-IN& <br />WIRB LAYER -1, <br />STUCCO WRAP <br />WRB LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />WOOD <br />COVSTUCTICN <br />.. —METAL LATH <br />a' CMU x <br />YINTL CASING BEAD <br />RAISED BAND <br />Y ; <br />X' TO1S HID-U ALL <br />WEEP SCREED <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER #2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH xxx—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1,1 / ASTM C-847-09, MIN, 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FIN15H <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING: <br />UNIT <br />PREMANUF. DRYER <br />VENT GAP (SET IN <br />CONT. SEALANT) <br />SEALANT m <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />&' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SF"ECSJ <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />r — _ — 7 <br />VENT PENETRATION <br />1-1 SCALE: N.T.S. <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />.ASTER <br />T/e' TO )e' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME <br />APPLY STUCCO SCRATCH GOAT <br />AND ONE (U LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />/ ­==^ DTI ­ `JR SIMII <br />LAR <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />::O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />ELECTRICAL CONDUIT <br />PENETRATION <br />GUT OPENINGS IN <br />APPROVED 1-101,15EWRAP <br />FOR BOX INSTALLATION <br />WR8 LAYER 01, <br />5TUCCO WRAP <br />WOOD SHEATHINGS <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FA( <br />EDGE <br />APPLY E-Z <br />OVER 60 M <br />GRADE '0' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTER5ECTIC <br />WOOD SHEATHING <br />WRB LAYER -1, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FtN[GW .TWO D <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.C. MAX <br />7b' TO 3S' MID -WALL <br />WEEP _GREED <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYRYa <br />V FINIaH r MASONRT <br />�B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />STEP #1 <br />STEP #3 <br />STEP #E� STEP #ro <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-7746078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA #: 0003325 <br />w <br />8 <br />W <br />O <br />4 <br />0 <br />A <br />4 <br />r <br />W <br />W <br />O <br />S <br />W <br />O <br />L A <br />SILVERADO <br />LOT #48 <br />BLK #6 <br />PROJECT# <br />04128.002-48061 <br />MODEL- <br />4EBB <br />"1828-CALI" <br />GA12AGE BVING: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />ARCHITECT- <br />STATE- OF FLOPoDA <br />ROLAAABOV <br />I PH <br />DATE: 01/18/19 <br />SCALE: 1/4"=1'-0" <br />81-MET <br />dd A2 <br />