My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6783 Ezra Loft Pl
Zephyrhills
>
Building Department
>
Building Plans
>
6783 Ezra Loft Pl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:15:59 AM
Creation date
2/19/2025 12:13:36 PM
Metadata
Fields
Template:
Building Plans
Street #
6783
Location
Ezra Loft Pl
Contractor
DR Horton
Building Plans - Permit #
20984
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2'-8" <br />FOUNDATION PLAN <br />SCALE: 1/4" = V-0" <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +-0'-U". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWSE. <br />4. REFERENCE ELEVATION+-0'-0", SEE SURVEY PLOT FOR NGVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE VVLTH THE RULES AND LAMAS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WTH ARCHITECTURAL <br />DRAWINGS <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WTH THE <br />WINDOWDOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11. INDICATED #5 BAR, IiNDICATES #6 BAR, ■DICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90- <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6 =36'), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWSE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWSE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WTH A.C.I.530-13/ASCE 5-13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: Fm= <br />1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND. <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 'OF SLAB SUPPORTED <br />T-0" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 6th EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />REINF. <br />REMARKS <br />6.6-.4-1.4 OVER <br />GENERAL <br />3 12' <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS, SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 30" LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM <br />TOP REINF. <br />T.O.F. <br />SHORT <br />TE-1 <br />8'• <br />SEE PLAN <br />10' <br />- <br />+)p'{1• <br />FM-12z12 <br />17, <br />CONTINUOUS <br />17' <br />- <br />FM-12z18 <br />12, <br />CONTINUOUS <br />19, <br />- <br />U#5*� <br />FW16X18 <br />16' <br />CONTINUOUS <br />19, <br />- <br />FMC-19A8 <br />12, <br />CONTINUOUS <br />18" <br />- <br />- <br />VARIES <br />F-24X24 <br />24" <br />2C <br />12' <br />(-)0'4. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />w .abde igngmupmm <br />l AA #: 0003325 <br />R <br />W <br />h <br />r; <br />W <br />•y- <br />0 <br />F <br />y <br />W <br />A <br />F <br />9xmDIV. & IJDT: <br />S ILVERADO <br />LOT #48 <br />BLK #6 <br />PROJECT* <br />04128.002-48061 <br />MODEL• <br />4EBB <br />"1828-CALI" <br />GAi2A0311 SFIIIQG: <br />RIGHT <br />PAGE: <br />FOUNDATION <br />PLAN <br />150 MPH EXP. B <br />WON <br />DATE: O1/18/19 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />si <br />
The URL can be used to link to this page
Your browser does not support the video tag.