I I <br />oreLE-Ero <br />TtwF WIND DESIGN NISSURES <br />ZONE 1 -8.97 PSF (19.97) <br />ZONE 2 - 17.98 PSF (27.98) <br />ZONE 3 - 33.53 PSF (43.53) <br />"A"- 4'-O" END ZONE DISTANCE <br />BASIC WIND SPEED: 150 MPH <br />WIND EXPOSURE: "B" <br />RISK CATAGORY: II <br />APPLICABLE INTERNAL <br />PRESSURE COEFFICIENT 10.18 <br />ROOF DMPf1tAl#&! <br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" <br />O.S.S. OR It2" CDX EXT, PLYWOOD, FOR <br />CEMENTITIOUS TILE AND METAL ROOFING, USE <br />MIN. 518 COX EXT. PLYWOOD, WITH Bid RING <br />SHANK GUN NAILS AT 4" O.C. AT SUPPORTED <br />PANEL EDGES AND 8d RING SHANK GUN NAILS <br />AT e" O.C. AT INTERMEDIATE SUPPORTS. SEE <br />DETAIL. <br />ROOF SHEATHING TO GABLE END FRAME USE <br />8d GUN NAILS @ 4" O.C. EDGEWISE ZA <br />BLOCKING ALL PANEL JOINTS W IN 4' OF GABLE <br />END. <br />ROOF/ WALU FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL SCHEDULE <br />SIZE <br />TYPE <br />MIN, LENGTH <br />MIN. DIA <br />SHANK <br />TENSILE SR. <br />SHANK <br />8d <br />RING SHANK <br />2 1/2" <br />0. 120" <br />170,000 <br />RING <br />SCREW SHANK <br />(16-20 RINGS <br />PER INCH) <br />8d <br />SCREW SHANK <br />21/7' <br />0, 12W <br />PNEUMATIC <br />SCREW -NAILS <br />i, NAIL SIZE PER ASTM F1864 <br />2. INTERNATIONAL STAPE, NAIL & TOOL <br />ASSOCIATION ([SANTA) ESR-1639 <br />EXTERIOR GWATNSki <br />USE 1/2' COX OR 7/18" O.S.B. PLY WITH Sd RING <br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES <br />AND 8d RING SHANK GUN NAILS 4" O.C. TOP & <br />BOTTOM PANEL AND 8d RING SHANK GUN <br />NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS <br />OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED <br />PER MANUF. SPECS.) SEE DETAIL <br />8d RING SHANK GUN NAILS ® 4" O.C. <br />TOP & BOTTOM EDGES <br />W . <br />Z <br />U <br />u o <br />J <br />Z <br />t0 <br />Q2 <br />2 ' <br />a <br />m <br />TOP CORD BLOCKING AT 4' <br />O.C. MAX. IN FIRST 2 FRAMING <br />SPACES AT EACH END. <br />RAFTER OR TRUSS <br />ROOF SHEATHING <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL BRACING <br />FOR OAELE END FRAMING <br />Bid RING SHANK GUN NAILS 012' O.C. IN <br />FIELD or Sd x 2 10 SCREW SHANK <br />PNEUMATIC SCREW -NAILS Q 12' 0,,C�ILJ <br />FIELD J\ <br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />OMER& NOTES: <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WTH JOB SPECIFICATIONS AND <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT <br />ARCHITECTURAL DRAWNGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAW NGS. APPUCABLE BUILDING CODE STANDARDS: FBCR 2017, BN EDITION <br />AG 318.14, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASIDE 7-10 ANDAISC SPECIFICATIONS <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT MERE A DIFFERENT DETAIL IS SHOWN. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />OF THE WORK. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTNG AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION, THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE -DOWNS. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND S1TE PREPARATION <br />REQUIREMENTS AND SLAB-014-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MNUMUM AGGREGATE SIZE SHALL BE 3W. <br />WOOD: <br />PROVIDE 6%AIR ENTRAINED CONCRETE 6910SED TO FAITH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. <br />ALL E)NOB® EDGES OF CONCRETE ARE TO BE CKAWGIE0 314'. <br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND MODULUS OF <br />PROVIDE 84AIL CONTINUOUS NEd11B2 POLYETHYLENE VAPOR BARRIER MEMBRIALL S.ABBONGROUND NIX RIIXCATED ON <br />ELASTICITY- 1,400,000 PSI. ALL MOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SMALL BE <br />DRAWINGS. SEAMS LAPPED 8 INCHES AND REAL®Y8M WII�NE THE <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES <br />SHALLSE TEE' TO E TREATMENT: DISODIUM <br />OF <br />MELS <br />FORWORK: <br />CORROBORATE TETRAHEDRAL (DOT). .WOOD FOR STRUCTURAL USE SMALL BE TREATED FOR ANY <br />FORMWORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0,42 PCFFOR DOT OR MORE. MAILS, SPIKE, BOLTS USED <br />AND FOOTINGS SHALL BE DESIGNED AND CONSRUCTED IN ACCORDANCE WTHACI 347, <br />W DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT <br />'RECOMMENDED PRACTICE FOR CONCRETE FORMAMORK. <br />CONTAINS MORE THAN %' OF HEARTWOOD. <br />EXCLUSION" FROM THESE PLANS: <br />MIN MUM NAILING PER FBCR 2017, ft EDITION. SEE NAILING SCHEDULE ON PLANS. <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL. DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WTH 2x STRUCTURAL LUMBER <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. <br />SYP 02. <br />WELDED WIRE MESH: <br />WELDED W RE MESH, SHALL BE ASTM A185, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE ACI <br />TYPICAL DETAILS. MI NIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. W RE MESH FOR SUBS SHALL BE <br />SUPPORTED WITH 2' CHAIRS SPACED 3'-O' OC, EACH WAY. <br />DO NOT SCALE DRAWINGS, THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: <br />TO WORK PERFORMED AND SHAL NOTIFY RE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A815 GRADE 00 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACEDIN <br />ACCORDANCE W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND <br />DESIGN LOADS: SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO <br />FABRICATION. HORIZONTAL AND VERTICAL SARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE <br />SUBJECT TO ENGINEER'S REVIEW. <br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 pat TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" <br />20 PST TOP CHORD -ror-orwirerit #5 BAR - 30' #7 BAR - 42' <br />10 pef BTM CHORD noncanwrre0t PROVIDE 36' x 36' CORNER BARS, BOND BEAM ONLY, UPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />FOR ADDITIONAL INFORMATION, <br />DEAD LOAD DEAD LOAD <br />15 pef TOP CHORD 20 psf TOP CHORD <br />(7 "1' w/ ASPHALT SHINGLES) (10 psf Md No GYPCRETE) <br />10 psf BTM CHORD 5 psf SI M CHORD <br />DEAD LOAD TO RESIST W ND UPLIFT'. 1 Opsf <br />BALCONY LIVE LOAD 60 psi <br />STAIRS LIVE LOAD 40 psf <br />WIND: DEAD LOAD SPEED =110 MPH 3- SECOND GUST <br />(ASCE 7-10 (FBC R2017) EXPOSURE B, RISK CATEGORY 11) <br />SHOP DRAWING REVIEW: <br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPUANCE WITH THE DESIGNING INTENT <br />OF RE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO <br />THE ARCHITECT. DRAWINGS SUBMITTED WITHOUT REVIEW W LL BE RETURNED UNCHECKED. <br />SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS ICON - <br />TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSION FROM <br />THE ENGINEER <br />IN ALL INSTANCES, THE CONTRACT DOCUMENTS W LL GOVERN OVER THE SHOP DRAWINGS <br />CHECKED, UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ARCHITECT. <br />FOUNDAMINI SITE PREPARATION: <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2.000 psf, <br />FOOTING EXCAVATIONS AND SLAB 9U94RADE SHALL BE COMPACTED TO A DRY DENSITY <br />OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN <br />ACCORDANCE WTH ASTM D-1557. TREAT ALL SOIL FOR TERMITE PROTECTION. <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNCAL ENGINEER <br />TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS <br />FAILING TO MEET THE GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND <br />RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT, WRITTEN <br />CERTIFlCATION THAT RE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION <br />REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER. <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS <br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB <br />CONTRACTOR SHALL SUBMIT PROPOSED MX DESIGNS, WITH HISTORICAL STRENGTH DATA <br />FOR EACH SEPARATE MIX PROR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL <br />NOT EXCEED 7-1- PROR TO THE ADDITION OF PLASTICIZER <br />CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C44 OR <br />MFAWRNG, MXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED <br />WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED <br />TO THE NIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MM/TES. <br />IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN <br />90 MNUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBUTYOF <br />THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WITH THE <br />ABOVE <br />REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS <br />A 3-FOR CONCRETE CAST AGAINST AND PERMANENTLY DFOSEDTO ENRH(FOUDATIONST <br />B FOR CONCRETE EXPOSED TO EARTH AHDORWEATHER <br />1-1/2' FOR #5 AND SMALLER <br />2" FOR #8 AND LARGER <br />C. FOR CONCRETE NOT.E)POSEDTO WEATHER <br />314- FOR SLABS, WALLS AND JOISTS <br />1-112-FOR WMM AND COLUMN PRWVRY REINFORCEMENT, TIES STIRRUPS <br />ALL VERTICAL REINFORCING BARB IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WTH <br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE <br />WALL. <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS, DOWEL <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />WITHOUT THE APPROVAL OF THE ENGINEER, <br />MASONRY: <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WTH ALL REQUIREMENTS OF THE <br />"SPECIFICATION MASONRY STRUCTURES" (ACI 5301 ASCE 5/TMS 402, BUILDING CODE REQUIREMENTS FOR <br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS <br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. <br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-00, GRADE f. = 1500 PSI. BLOCK SHALL BE PLACED USING <br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WTH <br />ASTM C-478 AND SHALL PROVIDE A MI MMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS UNLESS <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3W <br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF 8" TO 10'. USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />TYPE'TM" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />PROPORTIONED AND MIXED AS OUTLINED UNDERASTM C-270 . HORIZONTALAND VERTICAL MORTAR JOINTS <br />SHALL BE 3/8"THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />CELLS TO BE FILLED. <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANCOR VERTICAL <br />REINFORCING. <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />STRUCTURAL STEEL: <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WTH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHAL BE ASTM <br />A38, FY = 38 ksi FORANGLES, PLATES, AND WSHAPES. SRUCTURAL TUBING SHALL BE ASTM ASW, GRADES, <br />Fy= 46 low, STRUCTURAL PIPE SHALL BE ASTW3, GRADE B. TYPE E OR S, Fy =35 ku. TUBE AND PIPE <br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL <br />OTHER BOLTS SHALL BE ASTM A325-N BOLTS WTH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL <br />BE TIGHTENED IN ACCORDANCE WITH THE TURNOFF -THE -NUT METHOD. <br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES. <br />WOOD TRUSSES: <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THENATIONAL DESIGN SPECIFICATIONS FOR <br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNEDAND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWNGS. <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL <br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:. AND "TPIAVTCA BCSI V <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER W LL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTH ANSI A56.1-1982. <br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. <br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAW NGS FOR ALTERNATE CONNECTION DETAILS AT <br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />PROVIDE ENGINEERED SHOP DRAW NGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTON <br />PLAN SHOW NG COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />LICENSED PROFESSIONAL ENGINEER <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />PROVIDED BY THE TRUSS ENGINEER. <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />OF THE DELEGATED TRUSS ENGINEER. W ND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7.10 COMPONENT <br />AND CLADDING W ND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE'USP STRUCTURAL <br />CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTAL CONNECTIONS <br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE <br />LATEST CATALOG. <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCKFASTENERS <br />FASTENER <br />APPLIUTION <br />SIZE <br />TYPE <br />&PAC1N0 <br />REMAT.O <br />APPL1GTgJ <br />Sim <br />TYPE <br />3PAgN0 <br />REMARxS <br />tYt PTNRRNJ <br />CASE IaRDFN®COL <br />OMIGE DOOR BIIG( <br />SEE.ETAL <br />SEE DETAILSEE <br />DETAIL <br />SEEDETAIL <br />MASONRY/CONC. <br />NAIL11?LONG. <br />S OC <br />TO MA90NiVlOOro <br />SGO, AL.IXT.DOOR9 <br />CASE WNDBJ®COIL <br />A'O.E <br />WMDOwDOOR/FASTEN® <br />OMAGEOOORBIICK <br />SEE OETNL <br />SEE GETNL <br />SEE DETAL <br />SEE DETAL <br />II PT, SEEN 6 <br />NAIL 11?LONG, <br />9TAOOBRED <br />INTO 9�MRY/COIL <br />TO M48DNRYIOJNC. <br />YMIDOW_ <br />CASE 1NR0@IEDC- <br />S"qC <br />WMwWNOORIFASTE1iED <br />METALSTRAPTO <br />CONTACT THIS ENGINEER FOR SPACING <br />1•1,9EE—. <br />NALI III LONG. <br />STAGGERED <br />INTO MABONRYgONC. <br />MASOM—coNC. <br />REQUIREMENTS <br />EXT. 81NINo mCR <br />(?)311 A'W <br />-TAPO-JN' <br />11Y1"EMBEDS'EID. <br />NCTI9EAPoN3 N000 <br />1o_ E%PAJ90N A"EMBED.<"BD <br />3x OF <br />BUCK 1. PT SEE NOTE. <br />NO WASH6i <br />FA.—ICOC <br />DIST.. 11?EOoE 018f <br />WALL TO CONIC. BITS <br />WI Wp91Hi BOLT DIST., 3'EDOEgei. <br />PT WINDOW SUS( .. ""A"" S•Ox: VEND. D18T, 111 <br />PT T To STEEL q)L..SEE W1 WAelER STAGGERED EDGE 013r <br />NOTE. <br />11. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS • <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND/OR NOA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. PAF SHALL BE HALT X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />S. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />6. WIN DOW AND DOOR SUCKS SHALL BE AS W DE OR W DER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. ix MEMBERS ARE NAILED AND <br />2x MEMBERS ARE SECURED W TAPCONS OR PAF TO THE SUBSTRATE. <br />- <br />1441 N. RONALD REASAN BLVD. <br />LONGWOOD, FL 32780 <br />PH: 407.774.6078 <br />FAX: 407-774-4078 <br />wwwAbdeaWWouP.com <br />AA N: 0003328 <br />emm� <br />suzwTv. as XIOM <br />SILVERADO <br />LOT #51 <br />BLK. #6 <br />PlwJwT <br />041 8. -5 061 <br />1[ODEIC <br />4EHB <br />112605- HAYDEN"' <br />GARAGs 8WENC: <br />RIGHT <br />PAGIM <br />DETAILS <br />150 MPH EXP. B <br />