My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6809 Branham Mill Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6809 Branham Mill Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:25:49 AM
Creation date
2/19/2025 12:30:24 PM
Metadata
Fields
Template:
Building Plans
Street #
6809
Location
Branham Mill Ct
Contractor
DR Horton
Building Plans - Permit #
3441
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />2403 SQ. FT. <br />If 53`SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />461 SO. IN. <br />UPPER VENT 50% NET VENT MAX. <br />577 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />4 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />SS2 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />601 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF.1 <br />92 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL SG PERMITTED: <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />ROOF PLAN <br />SCALE: 1 /4"=1'-O" <br />cr- <br />W <br />�-_CC <br />�i001=- <br />>�QO <br />W�o1- <br />(nUWW <br />¢awl- <br />2 CC <br />J <br />> <br />cr It <br />Y O F- z <br />,6LLO0C/) <br />z z z w <br />J Q J <br />oC(L <br />U) p O U <br />�2zLLU) <br />�I - <br />-QzWOMEN <br />r` <br />� C <br />gH <br />Z <br />0 <br />0 <br />r� <br />V <br />cif <br />ii <br />O <br />� <br />w <br />U) <br />4t <br />IMMMMI <br />z <br />O <br />(L <br />:3 <br />O_ <br />U <br />W <br />OQ <br />an <br />o <br />irZ <br />as<11 <br />DEC 17 202 <br />COMMUNITY: <br />LINKS @ CALUSA SPRINGS <br />PLAN #610i <br />RELEASED: 12/28/21 <br />SHEET <br />A3. I <br />
The URL can be used to link to this page
Your browser does not support the video tag.