Laserfiche WebLink
A R C H I T E C T S <br />INSTALL W SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST, <br />SEQUENCE OF FLASHING TO BE: <br />I. BOTTOM 2 SIDES 3. TOP <br />-XVENT CAP 18 TO BE SET IN BED <br />X OF SEALANT AT TOP AND <br />1 -1 SIDES ONLY. SEALANT IS TO BE <br />II TOOLED 50 AS TO DEFLECT <br />IWATER AWAY FROM JOINTS. <br />X.: E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i x JOINTS AND INTERSECTIONS <br />I <br />I APPLY SEALANT AT PERIMETER OF <br />BACKER ROD NON -MOVABLE FRAME AND STUCCO <br />A«LJL LLOUNDS, y4 CAULKING ® JOINT <br />PER FBC R703_6.1 <br />Exterior lathin0 and�lastering <br />BACKER ROD Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />I <br />1 ?� Installation of exterior lathing and framing <br />x.I shall comply with ASTM C 7063-7 2A. <br />WRB LAYER -1,- <br />$Tucco WRAP I x <br />HOODED VENT <br />x <br />X: J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIRBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />6 A DRYER VENT (FRAME. <br />WOOD SHEATHING <br />WRB LAYER h, <br />STUCCO WRAP <br />WRB LAYER -1, FORTIFIBER <br />BUILDING PAPER <br />WDOD s. <br />CONSTUCTION � <br />-METAL LATH <br />a' CMU VINYL CASING BEAD <br />`4 6' RAISED BAND <br />n;. <br />V TO $' MID -WALL <br />WEEP SCREED <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER "l, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO L ' ° <br />WOOD SHEATHING I�JIZIII�T1� <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R-103.6.1 / ASTM C-84l-01B, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />&' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />vENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT e <br />TOP a SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH — <br />WALL <br />6' SELF ADHESIVE <br />FLASHING ONSTALI <br />PER MANUF. SPEC; <br />BUILDING PAPER <br />UNDER 'QUICK FL< <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />,• 7=f I v m=l..=I y= <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/B,4CK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />i <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />1 <br />i <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />'THICK, 3 COAT CEMENT <br />%* TO Ye' MID -WALL <br />WEEP SCREED <br />�—ro' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />A, �T I - 7R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:;O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING fN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER "I, <br />STUCCO WRAP <br />UIOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />SU CUT CH THAT_ <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />UAFB LAYER -1,STUCCO WRAP <br />U1RB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1/0' TEXTURED <br />CONSTRUCTION -FINISH - WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER - l' O.C. MAX <br />B' Q111 <br />- k'TO)V MID -WALL <br />- IICFP l'oCFn <br />• W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />H <br />V FIN16- MASDNRT <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />a• <br />WRB LAYER -I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING X <br />MEMBRANE FLASHING / t <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRBLAYER <br />-I <br />STEF #1 <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />NOUSEWRAP <br />STE F *`3 <br />5TEP *2 <br />WRB LAYER 01, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />5TEF *5 5 T E F #ro <br />(�) ELECTRICAL RECEPTACLE <br />LONG WOOD, FL 32760 �• V <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdosigngmup.com <br />AA M: 0003325, <br />y <br />U <br />0 <br />c <br />a <br />V <br />BVHDIV. & LOT: <br />SILVERADO <br />LOT #3 <br />BLK #7 <br />PAOJL'CTd1 <br />04128.000-00371 <br />HODNIs <br />4EBB <br />"1828— CALI" <br />GARAGM BWZNG-. <br />LEFT <br />PAGM <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />ARCHITECT <br />STATE OF FLORIDA <br />(RA <br />[RIC6. <br />R O 93723 <br />D TM 10/19/17 <br />aCALM 1/4"=1'-0" <br />e1KOW <br />A2 <br />