My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6976 Silverado Ranch
Zephyrhills
>
Building Department
>
Building Plans
>
6976 Silverado Ranch
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:24:40 AM
Creation date
2/19/2025 11:44:54 AM
Metadata
Fields
Template:
Building Plans
Street #
6976
Location
Silverado Ranch
Contractor
DR Horton
Building Plans - Permit #
21278
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />M S. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED UTN GLASS PAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603, <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES 614ALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL. BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED M ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (20PI) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LIKE- RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE R.P.E. ELEVATION. 11 <br />ALL HVAC TO HAVE PROPER <br />12XS <br />— --- <br />— <br />PANS W/ DRAINS <br />PANS <br />SECURE STRAP TO CONC. <br />CONDENSER <br />-------------------- <br />I <br />14X14 <br />W/ (2)-3/16'XV TAPCONS <br />UNIT <br />WB ROLL STRAP <br />1 <br />I <br />I <br />4' <br />O <br />>ATTIC <br />OR <br />OR EQUAL <br />4' 0. y® <br />CEILING <br />EXTERIOR WALL <br />- --- <br />_ _ _ — — _ _ --, <br />X j BATH CRN <br />a6 <br />WAX <br />PLENUI.1 <br />1 <br />y <br />AIR RETURN <br />4' CONCRETE BLAB <br />SECURE STRAP TO UNIT W/ (2) <br />°SXI 1/4' SHT. MTL. SCREWS <br />' I <br />I i <br />° ° <br />14' <br />— — — — — — <br />SUCTION AND LIQUID <br />WCHE <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />- --- <br />---- �� <br />I <br />- - - - - - <br />AIR HANDLER -----EXTERIOR <br />CONNECTION <br />TO PAD <br />WALL <br />X;¢_ <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />O <br />6 <br />OVER HEAD a 12' FROM STRUCTURE <br />_ <br />3 <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />-- - <br />BDRM. _$4/ <br />? <br />REFRIGERANT LINES TO <br />O DEN <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />4' DRYER <br />I0X6 <br />TRAP DRAM LINE AND TERMNATE <br />V. <br />X . <br />M AN APROVED DRAIN, AS PER <br />v <br />POOR 6TH EDITION (2011) <br />I <br />I <br />MECHANICAL SLOG. CODE <br />SECTION 3012.4 <br />I <br />— <br />HVAC <br />DRAINS <br />IOX6 �' <br />4' <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />COUNTERSUNK <br />CA. PLUG <br />® <br />14X6 <br />f`ya1J�1 <br />II <br />gg�0 I I <br />CFM 8X4 II <br />I I <br />� <br />I <br />L------ <br />r-6' <br />1® J-I SX4 <br />SEE SPEC <br />GARAGE <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />(D LOOR SLAB CLEAN -OUT (TY <br />FIN. GRADE <br />OR PAVING <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYPN <br />MECHANICAL PLAN <br />SCALE: 1/4 . I'-0' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD,FL32750 <br />PH:407-7746078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M: 0003325 J <br />SUBDM rk LOT: <br />SILVERADO <br />LOT 9 <br />BLK 7 <br />PROJECT* <br />04128.002-09071 <br />MOD= <br />4EBB <br />"1828-CALL" <br />GARAGE BQING: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%,.150 MPH EXP. RJ <br />2 <br />DrANT <br />ATE: 01/17/19 <br />8CALE: 1/4"=1'—O" <br />8HEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.