My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6979 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6979 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:32:38 AM
Creation date
2/19/2025 11:35:54 AM
Metadata
Fields
Template:
Building Plans
Street #
6979
Location
Silverado Ranch Blvd
Contractor
DR Horton
Building Plans - Permit #
21349
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4" CONC. <br />�OSL�A.e <br />TT OP OF 0 <br />sLAB <br />10'.A" <br />28'4r <br />3t4" <br />15'-1(r <br />9'45' <br />9'-8" <br />'-4" <br />— 1 <br />— — — 7 — FM-12X12 <br />— — — — — — FM-12X18 — <br />IS 4" CONC. <br />A <br />I SLAB <br />F-24X24J 11-0. +3 IQ <br />t0 <br />1.1 <br />EXTEND FM-/2X18 <br />i <br />SLAB 1 1/2" <br />1. <br />I <br />, <br />I <br />I <br />I <br />I <br />�4TOP <br />OF <br />I. <br />SLAB <br />i5 <br />ILL <br />I <br />I <br />I <br />•I <br />I <br />�I <br />I <br />I <br />I <br />LLI <br />I <br />I• <br />I <br />I <br />4" PVC <br />I <br />L <br />CHASE <br />TE•1 <br />1.1 <br />— — — — <br />+ 5 112 <br />4-1 <br />,• 13� 5 <br />I <br />I <br />. ILL <br />o <br />I <br />I <br />EXTEND <br />2 <br />1• <br />SLAB 11/7 <br />1• -- <br />4"C11C <br />FM-12X18 Iri <br />SLAB <br />3,1„ I INa -3,2 <br />�.77/2 <br />g) <br />a <br />2 J <br />MC-12X18 <br />FM-12XIS FMC-11- <br />FW 2 1i L1.1 FM-12XIS <br />1.1 <br />4 <br />4 <br />2'-8" <br />18'-0" <br />2'-8" <br />X-10" 10'-7 <br />21'4" <br />4'-4" 14'-0" <br />39'4r <br />FOUNDATION PLAN <br />SCALE: 1/4" = V-0" <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +-0'-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION +-0'-0", SEE SURVEY PLOT FOR NGVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAM AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1r2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />S. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOWVDOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />I I INDICATED #5 BAR, BNDICATES #B BAR, ODICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90" <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (05 = <br />Mr, #8.38'), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE 05'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I.53043/ASCE 5.13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I.530-13/ASCE 5.13, USING: Fm = <br />1,500 PSI, TYPE "M" OR'S" MORTAR, ASTM C476 GROUT MW PSI), UNITS LAID IN <br />RUNNING BOND, <br />16, WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER J OF SLAB SUPPORTED <br />3'-0" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, Mh EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />I REINF. <br />I REMARKS <br />8xB W1.4xW1.4 OVER <br />GENERAL <br />3 12' <br />B MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 3a' LEG EACH WAY. <br />MARK <br />I WIDTH <br />I LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />TEA <br />8" <br />SEE PLAN <br />,a' <br />- <br />s <br />FMAN12 <br />12• <br />CO TINUOUS <br />17 <br />2) #5's <br />FMAN18 <br />1 <br />CONTINUOUS <br />18" <br />2 #5's <br />+a-0" <br />FM-16x,8 <br />18' <br />CONTINUOUS <br />IS, <br />- <br />( 's <br />+a•.a' <br />FMC-12x18 <br />17 <br />CONTINUOUS <br />19, <br />- <br />( kVARIES <br />F-24x24 <br />24" <br />2 r <br />12' <br />s <br />(-)0'-4- <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774.4078 <br />www.abdmWWoup.com <br />L AA #: 0003325 <br />L1111111, <br />OVt3Dm a Lo <br />SILVERADO <br />LOT #54 <br />BLK #6 <br />PllOJOcTN <br />4 02-5406 <br />IWDZU <br />4EBB <br />"1828-CALM" <br />GARAGs OWING: <br />LEFT <br />PAGO: <br />FOUNDATION <br />PLAN <br />150 MPH EXP. H <br />DATM 01/m/19 <br />scAm. 1/4"=1'-0" <br />slum= <br />si <br />
The URL can be used to link to this page
Your browser does not support the video tag.