Laserfiche WebLink
A-(1)USP HTA78 TRUSS ANCHOR WITH (9) <br />10d x 1 1/2" TO TRUSS. FL#17680 <br />B-(2) USP HTA16 TRUSS ANCHOR WITH (9) <br />10d x 1 1/2" TO TRUSS EA STRAP. FL#17680 <br />DBL STRAP, 1 EACH SIDE WRAPS UP AND <br />OVER TRUSS (NOT SHOWN) <br />ix2, 2x WOOD FASCIA <br />SEE ARCHITECTURAL <br />2x SECURED W4(3),6d <br />GALV. COMMON NAILS. <br />tx2 SECURED W810d <br />GALV. COMMON NAILS / <br />12, O/C <br />MASONRY BOND BEAM <br />SEE SCHEDULE <br />PLYWOOD SHEATHING, SEE <br />"ROOF/WALUFLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />ENGINEERED AOOD <br />TRUSSES 0 24" O/C, <br />SUBMIT SHOP DRAWINGS <br />FOR REVIEW <br />AND APPROVAL <br />A ALLOWABLE UPLIFT = U:1870 LBS, L710LBS (1 STRAP) <br />B ALLOWABLE UPLIFT = U:2430 LBS, L1310LBS (2 STRAPS) <br />�-`� TYPICAL TRUSS/ <br />T„ (O GIRDER CONNECTOR(S) S LE: 114"=V-11' <br />314" T & G SUBFLOOR CLUED AND <br />SCREWED A$ PER SCHEDULE <br />PRE-ENG FLOOR TRUSS <br />518" GYPSUM BOARD OR i/T HIGH <br />STRENGTH CLG. BOARD <br />SECURE TRUSS TO TOP PLATE w/ (2) <br />16d TOENAILS <br />DOUBLE TOP PLATE <br />2x4 OR 2x6 WOOD BEARING <br />WALL W/ SYP No 2 STUDS SEE <br />PLANS FOR SPACING SINGLE <br />BTM. PLATE TO BE PT. <br />PROVIDE DBL. TOP PLATE <br />PROVIDE BLOCKING <br />1/2' GYP. WL. BD. <br />, SCALFLOOR TRUSS CONNECTION L.B.W. <br />E: 3/4"="0' (NO UPLIFT) <br />IGINEERED WOOD TRUSSES <br />PLYWOOD SHEATHING, SEE <br />24" O/C, SUBMIT SHOP <br />"ROOFAAfALL/FLOOR <br />:AWINGS FOR REVIEW <br />SHEATHING <br />ID APPROVAL <br />FASTENER SCHEDULE" <br />USP HTA16 TRUSS ANCHOR <br />:H (9) 10d x 1 7/2" NAILS TO <br />USS EA. PROVIDE C MINIMUM <br />NOTE: FOR (A)VW SINGLE <br />NCRETE EMBEDMENT, DBL <br />PLY, A PT SYP 022'XB"X4'-0" <br />RAP, 1 EACH SIDE WRAPS UP <br />MAY BE ADDED W/ 10d <br />D OVER TRUSS (NOT <br />NAILS, 2 ROWS, 3' C/C TO <br />OWN) <br />FACILITATE 2-PLY <br />ED IN CONJUNCTION WITH <br />CONNECTOR <br />AVY UPLIFT CONNECTOR <br />—(A) USP LGT2 W/ 15) 1/4W' POWERS WEDGE <br />BOLT& (16) 16 GALV. NAILS TO TRUSS (2PLY) <br />#FL17240 (NOT SHOWN) <br />(B) USP RFUS STEEL CONNECTOR WITH 14) <br />3/4"x8' WEDGE BOLTS AND <br />1x2, 2x WOOD FASCIA <br />(12) WS3 SCREWS FL#8223 <br />SEE ARCHITECTURAL <br />2x SECURED WN(3)16d <br />GALV. COMMON NAILS. <br />IF 4 BOLTS ARE USED <br />1x2 SECURED 1W 10d <br />MASONRY BOND ENSURE THAT CELLS ARE GROUTED <br />GALV. COMMON NAILS <br />BEAM SOLID, 8" EACH WAY OF BOLTS <br />12, O/C <br />SEE SCHEDULE <br />A ALLOWABLE UPLIFT = U:3980 LBS, L1785 LBS (2PLY) <br />B ALLOWABLE UPLIFT = U:9000 LBS, L:1310 LBS (4 WEDGE BOLTS IN RFUS) <br />TYPICAL ROOF <br />2A 26 <br />SCALE:34"=1'-e <br />GIRDER CONNECTOR(S) <br />C: <br />d <br />W� <br />OTCH DEPTH 1/4"D <br />OLE EDGE>5l8" <br />OLE DIAMETER <br />< 2/5'D SGL. STUD <br />OUTER 1/3 OF <br />e(�- <br />SPAN ONLY <br />BTM. - <br />PLATE <br />STUD NOTCHING <br />AND BORING LIMITS <br />W/ 10dxl/2 HPG COMMON NAILS, <br />EACH END TOTAL OF 10 <br />FLOOR <br />GIRDER —1 — <br />HTT4 W/ 5/8' A.B. WITH <br />MIN. 7" EMBEDMENT <br />TO SLAB & (20)16d x <br />2-1/2" NAILS TO POST. , <br />POST TO SIT DIRECTLY <br />ON SLAB —� <br />ER/WOOD POST CONNECTIONS <br />DGqlERDq <br />SCALE: 3/4"=l'-0" <br />llimimi■ME' <br />■.�mm <br />' <br />I <br />,.E EDGE >60 A - USP THDH28 G < 1200 LBS, U < 1280 LBS W/ (1) 31V USP WEDGE-SOLT/J-BOLT, 5" MIN. <br />EMBED (20) 16d GALV. COMMON NAILS AND (8)16d VALV. COMMON NAILS, FL#17232 <br />B - USPTHOH26 G < 2400 LBS, U < 1425 LBS W/ (2) 3/4'1 USP WEDGE-BOLT/J-BOLT, 5" MIN. <br />EMBED (20) 16d GALV. COMMON NAILS AND (10)16d VALV. COMMON NAILS. FL#17232 <br />C - USP THDH28-2 G < 2400 LBS, U < 2660 LBS VW (2) 3/4' USP WEDGE437LT/J41OLT, &' MIN. <br />EMBED (38) 16d GALV. COMMON NAILS AND (10)16d VALV. COMMON NAILS, FL#17232 <br />D - USP THDH28-2 G < 4800 LBS, U < 2660 LBS W9 (4) 314'" USP WEDGE-BOLT/J-BOLT, S' MIN, <br />HOLE DIAMETER EMBED (38) 16d GALV. COMMON NAILS AND (10) 16d VALV. COMMON NAILS. FL#17232 <br />< 3/5'D DBL. STUD E - USP THOH28.3 G < 4800 LBS, U < 2650 LBS VW (4) 3/4- USP WEDGE-BOLT/J-BOLT, 5" MIN. <br />EMBED (36) 16d GALV, COMMON NAILS AND (10)16d VALV. COMMON NAILS. FL#17232 <br />WOOD LEDGER <br />9 ATTACHMENT DETAIL <br />SCALE: 3/4"=7'-0" <br /># 1175 UPLIFT USP <br />HTWM20 W/1010d TO <br />TRUSS AND (4) 1/4" x 21/4" <br />TAPCONS TO CONE <br />POURED LINTEL <br /># 1900 UPLIFT (2) USP <br />HT WM20 INSTALLED ON <br />OPPOSITE FACES OF <br />BLOCK WALL W/1010d TO <br />TRUSS AND (4) 1/4" x 2 1/4" <br />TAPCONS TO CONT <br />POURED LINTEL <br />PRE-ENG TRUSS <br />CONTINUOUS BOND BEAM <br />TAP CONS MIN. 2' <br />COVER 2" APART <br />REPAIR OF MULTIPLE <br />3 MISPLACED EMBEDDED TRUSS ANCHOR <br />SCALE: 3/4"=r-a' <br />(2) 2X4 No.2 SYP DIAG. <br />2x4 BLOCKING BETWEEN <br />BRACE W/ (3)12d Q EA <br />TRUSSES WHERE <br />TRUSS(DIAG. BRACE TO <br />X-BRACING IS PRESENT AT <br />COVER 5 TRUSSES) <br />4'-0" O.C. (AT SHEATHING <br />0'-0" TO 30'4' (1) "X' BRACE <br />SEAMS) <br />30'-1" TO 60'-0 (3)'W- BRACE <br />ECURE 2x8 PT. PLATE <br />(1) "X" BRACE O CENTER <br />TO BLK W/ 1/2" DIA <br />(2) 'X" BRACE DIVIDED EQUALLY <br />ANCHOR BOLT W/2" <br />FROM CENTER TO END. <br />WASHER SET IN HIGH <br />2x WOOD FASCIA, <br />STRENGTH EPDXY 8' <br />SEE ARCHITECTURAL <br />MIN. EMBED. AT 32'OC <br />MAX <br />PRE-ENG GABLE TRUSS <br />SECURE GABLE TO 2x8 <br />P.T. PLATE W/ 12&1 B" <br />STIFFBACK (ASPER <br />O.C. MAX <br />TRUSS ENG) <br />ONT. 2x4 SECURED VW/ <br />(2) 10d'4 0 EACH TRUSS <br />TO BE INSTALLED <br />10'-0" O.C. MAX. <br />5'EDGE <br />CENTRAL <br />SPACING <br />SPACING <br />SEE <br />SEE A T <br />WHEDLILE, <br />SCHEDULE �SEE PLAN <br />SEE SCHEDULE FOR BOLT SIZE <br />. <br />SEE LEDGER SCHEDULE gj <br />5 1/2" MIN. EMBED. (TYP) <br />1. ENSURE THAT EXP. BOLTSM-BOLTS ARE <br />PLACED INTO GROUTED CELLS, 8' ALL ARCUND <br />BOLT. <br />Z <br />1 END OF FRONT AND REAR LEDGER SHOULD <br />°D <br />LAP A MIN OF 4'4". <br />3, ALL BOLTS TO HAVE WASHERS <br />4. EXP. BOLTS/J-BOLTS SHOULD NOT BE ANY <br />1p <br />CLOSER THAN 8' O/C. <br />S. IN LIEU OF HILTI PAPS, i/4" DIA x 8' MASONRY <br />121 PT <br />SCREWS (TAPCONS) MAY BE USED, SAME <br />LEDGER SCHEDULE <br />MARK <br />SIZE <br />BOLT SIZE <br />WOMPACINS <br />CENIM WACp0 <br />A <br />DOUBLE 2x8 <br />1/7, <br />8" O/C <br />10" O/C <br />B <br />DOUBLE 2x8 <br />3/4" <br />8" O/C <br />24" O/C <br />C <br />DOUBLE 200 <br />112' <br />8" O/C <br />IV, O/C <br />D <br />DOUBLE 200 <br />3/4" <br />8" O/C <br />24" O/C <br />E <br />DOUBLE 200 <br />3/4" <br />6" O/C <br />18' O/C <br />F <br />DOUBLE 2xi2 <br />3/4" <br />1 5" OC <br />12' O/C <br />810 WOOD LEDGER DETAIL <br />scALE: a4" 7- <br />SEE SCHEDULE FOR <br />BOND BEAM REQ. <br />BLOCK WALL W/ GABLE END <br />PRE-ENG'D TRUSS SCALE: �""_' ° <br />THE USE OF ALTERNATE MATERIALS MAY BE <br />USED SO LONG AS THEY CONFORM TO THE <br />FOLLOWING <br />1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS <br />A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS <br />EQUIVALENT OR GREATER UPLIFT AND LATERAL (F7 AND F2) LOAD CAPACITIES <br />AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND <br />ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE <br />THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO <br />A USP RT18A (FL#17236) OR LUGT2 (FL#17240). ROOF TRUSSES ARE SUBJECT TO UPLIFT, Fl, <br />AND F2 FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE <br />SUBJECT TO F1 AND F2 FORCES. <br />11 ALTERNATE MATERIALS <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />www.abdesoigroup.com <br />AA #: 0003325 <br />Hamm <br />IQUDDIR A# LOT: <br />SILVERADO <br />LOT #55 <br />BLK" #6 <br />PROJECTM <br />04128.002-55061 <br />IcoasT, <br />4EHB <br />"2605- HAYDEN" <br />GAiRAoa OWnM: <br />RIGHT <br />PACE: <br />DETAILS <br />%150 MPH EXP. B <br />L \Am NO W723 J <br />rATM 1/18, 9CALM: 1/4"=1'-0"Mcm <br />S3.1A <br />