My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6988 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6988 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:42:40 AM
Creation date
2/19/2025 11:57:59 AM
Metadata
Fields
Template:
Building Plans
Street #
6988
Location
Silverado Ranch Blvd
Contractor
DR Horton
Building Plans - Permit #
21348
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FCC 6TH EDITION (2011) MECHANICAL OLD& CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL 6E APPROVED UL 184 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FDC 67H EDITION <br />(2011) MECHANICAL CODE 603J <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL NAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS ALL HAVE AN APPROVED FIRE OR FIREAMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. REC0MAMENDATIONS AND FDC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DDF BOOSTER FAN OR EQUAL. <br />PANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DFPUSER <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE• RETURN TRUNK <br />l <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL 14VAC TO NAVE PROPER <br />PANS W/ DRAMS <br />SECURE STRAP TO CONC. CONDENSER <br />R <br />ATTIC <br />W/ (2)-3A6'X2' TAPCONS <br />SIMPSON WB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUMAFETURN <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ <br />"SXI V4' SHT. MTL. SCREWS <br />(2) <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />REFRIGERANT LIKES <br />CONDENSER <br />UNIT <br />HANDLEREXTERIOR <br />CONNECTION <br />TO PADAIR <br />WALL3/4' <br />PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN COND. DRAIN 3/4'DIA.OVER <br />HEAD 12'FROM STRUCTURE <br />EVAP.TRAY <br />PVC SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORM <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL OLD& CODE <br />SECTION W12.4 <br />HVAC <br />DRAINS <br />FEO <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN, FLOOR <br />OR WALL <br />COUNTERIBUNK <br />C.O. PLUG <br />r- SEE SPEC. <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />/- WADE 8240-K JOSAM 56000 <br />INSIDE / SERIES NICKEL BRASS TOP <br />CAULK /" P.V.0 OPTI/SPEC <br />TFL00R SLAB CLEAN -OUT (TYPN� <br />FIN. GRADE <br />OR PAVING <br />I'-8'XB' CONC. <br />PITTING OR <br />EXTENSION TO BOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (T <br />MECHANICAL PLAN <br />SCALE: 1/4 G I'-C' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX 407-774-4078 <br />www.abdosigngroup.com <br />AA #: 0003325 <br />Pi <br />a <br />sumliV. a LOT: <br />SILVERADO <br />LOT 10 <br />BLK 7 <br />PROJECT# <br />04128.002-10071 <br />MODEu <br />4EBB <br />"1828—CALI" <br />GARAGE OWING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />0 MPH EXP. B.J <br />F'PRINTDAATEE: 01/17/19 <br />scALE: 1/4"=V-0" <br />SHEET <br />M1 <br />