Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />UFO LAYER -1, <br />STUCCO WRAP <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(b) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLA6161MG TO SE, <br />L BOTTOM, 2. SIDES. 3. TOP <br />VENT CAP * TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JONTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,V CALLKMG • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />EAerlor IW ft and 0leata M <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1083-12A. <br />HOODED VENT <br />]' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />CURD LAYER 02, FORTIFIBER <br />BUILDING PARR <br />WOOD SHEATHING <br />DRYER VENT (FRAME) <br />WOOD SHEATHING <br />UIRD LAYER M, <br />STUCCO UMRAP <br />UQB LAYER $2, FORTIFIBER <br />BUILDING PAPER <br />WOOD - <br />CONSTUCTION <br />-METAL LATH <br />a' CMU VINYL CABMG BEAD <br />6' RAISED BAND <br />,twee w,-ieen <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY B!POIlE APPLYING <br />Z PLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK! <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIF15ER - - - - - <br />BUILDING PAPER) <br />METAL LATH X—X—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />PLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT o <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' I— — — — <br />PIPE THROUGH <br />WALL <br />I <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />"7=0A I V ICC(..=1 V= <br />STUCCO SCRATCH COAT <br />a I COAT OF PAINT W)BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />9- THICK, 3 COAT CEMENT <br />PLASTER <br />Ya' TO V MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRS LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />ELEC. METER FIELD <br />BELOW <br />VERIFY LOCATION <br />CUT SUCWMEMBRANE <br />ANE <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY STUCCO SCRATCH COAT <br />APPLY To FAf <br />EDGE <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />Al ­R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />APPLY E-Z <br />OVER 6m MI <br />GRADE 'D' <br />FELT-F'ROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD 8HEATHNG <br />LAYER 91, <br />STUCCO WRAP <br />LAYER 7, FORTIFIBER <br />BUILDING PAPER <br />METAL <br />�L�AATH <br />GWTRICTION F�,_UUCPFM16H . aIOOD <br />'-' /FASTEN TO WOOD STRNOTURAL <br />{ MEMBER • 1' OTC. MAX <br />a' CMU <br />•' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />(�OHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />WIRE, LAYER'!, <br />STUCCO WRAP <br />4477 <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />M <br />STEP 01 <br />STEP *2 <br />WRB LAYER "I, <br />STUCCO WRAP <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />0 1 I.I 1.MEMBRANE FLASHING <br />WRB LAYER •2, FORTIF15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #& <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD RFAGAN BLVD <br />LONGWOOD,FL32760 <br />PH: 407.774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA M: 0003325 <br />b <br />O <br />,4A <br />L J <br />WIN M <br />aysDiv a< ><.oT: <br />SILVERADO <br />LOT #56 <br />BLK #6 <br />PROJECT# <br />04128.002-56061 <br />MODEZA " <br />4ENB <br />, <br />1751-NEUVILLE <br />GARAGE 9TrWG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />50 MPH EXP, <br />r7 <br />D � 01/17/19 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />WA2 <br />