FRAMING NOTES <br />1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE <br />CONCRETE TO WOOD ROOF: USP HTA16 W (9)10d x 1 VT HOG NAILS. <br />SMALL JACKS < 9' MAY BE NAILED W (10)d x 1 10 HOG NAILS, CONCRETE TO <br />WOOD FLOOR: <br />USP LPTA W/ (10) 10d x i 1/2" HDG NAILS, WOOD TO WOOD: <br />USP RT16A OR LUGT2 W/ 10d x 1 1 /2" HDG NAILS, FILL ALL HOLES. <br />2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER <br />SCHEDULE. <br />3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE <br />MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS <br />ARE TO BE GALVANIZED. <br />5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL <br />MANUFACTURER SHOWN IN STRUCTURAL PLANS. <br />S. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND <br />CLEAR SPAN OPENINGS. <br />7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4-). <br />8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE <br />SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE <br />FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS <br />LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND <br />APPROVAL, <br />9. PLACE 2X4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES <br />SECURE 2X MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED <br />FASTENER, ZF 72 PSS36, .177" ° x 2 7/8" LONG, WITH WASHER ® 16" O.C. <br />10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END <br />UNLESS OTHERWISE SHOWN DIFFERENT. <br />11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON <br />RATIONAL ANALYSIS. <br />12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS <br />NOTED OTHERWISE, <br />TRUSS MANUFACTURER / ENGINEER NOTES: <br />1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,600 LBS SHALL BE <br />FABRICATED W/ A 2x6 STM. CHORD (MIN.) <br />2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS <br />WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT <br />SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. <br />3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO <br />TRUSS CONNECTIONS. <br />4. AVOID PLACING A TRUSS PERPENDICULAR TOA STEEL COLUMN. <br />MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. <br />1-PLY <br />G: 498 LBS <br />U:-145LBS <br />2X4 BLOCKING BETWEEN TRUSSES 24" O.C. <br />TOE NAILED TO ADJACENT TRUSSES W/ (2)16d <br />COMMON NAILS & SECURE TO BM. W/ USP <br />FRAMING PLAN <br />SCALE: 1/4" - V-0" <br />1-PLY <br />U. -WOOS LBB <br />Ck 2204LOS <br />1-PLY <br />U: 40 L88 <br />G:1001 LBS <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407.774-6078 <br />FAX:407.774.4078 <br />www.abdeslgagroUP.mm <br />L AA A: 0003325 <br />anon, <br />swam & LAT: <br />SILVERADO <br />LOT #12 <br />BILK #7 <br />P1lon=TIP <br />4 2-12 71 <br />moaau <br />4EBB <br />"1828-CALM" <br />oARAOR 8WDM: <br />RIGHT <br />PAGIM <br />FRAMING <br />PLAN <br />150 MPH EXP. B <br />DA �` 01/18/19 <br />81CAt a: 1/4"=1'-O" <br />sxaaT <br />s3 <br />