oNILE-END
<br />HIP ROOF iF A'
<br />ROOF WIND DESIGN PRESSURES
<br />N (GROSS) ASCE-7-10--
<br />ZONE 1 •8.97 PSF (19.97)
<br />ZONE 2 • 17.98 PSF (27.98)
<br />ZONE 3 •33.53 PSF (43.53)
<br />"A"• 4'-0" END ZONE DISTANCE
<br />BASIC WIND SPEED: 150 MPH
<br />WIND EXPOSURE:'M"
<br />RISK CATAGORY: 11
<br />APPLICABLE INTERNAL
<br />PRESSURE COEFFICIENT+- 0.18
<br />ROOF DpMAIAGNI
<br />FOR ASPHALT SHINGLE ROOF, USE MIN 7116'
<br />O.S.B. OR 1/2" COX EXT. PLYWOOD, FOR
<br />CEMENTITIOUS TILE AND METAL ROOFING, USE
<br />MIN. 5/8 COX EXT. PLYWOOD, WITH 8d RING
<br />SHANK GUN NAILS AT 4" O.C. AT SUPPORTED
<br />PANEL EDGES AND 8d RING SHANK GUN NAILS
<br />AT 8" O.C. AT INTERMEDIATE SUPPORTS. SEE
<br />DETAIL
<br />ROOF SHEATHING TO GABLE END FRAME USE
<br />8d GUN NAILS E 4" O.C. EDGEWISE 2x4
<br />BLOCKING ALL PANEL JOINTS W IN 4' OF GABLE
<br />END.
<br />ROOF/ WALU FLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE
<br />NAIL SCHEDULE
<br />SIZE
<br />TYPE
<br />MIN. LENGTH
<br />MIN. DIA.
<br />SHANK
<br />TENSILE STR.
<br />SHANK
<br />8d
<br />RING SHANK
<br />2 10
<br />0.120"
<br />170,000
<br />RING
<br />SCREW SHANK
<br />(16-20 RINGS
<br />PER INCH)
<br />8d
<br />SCREW SHANK
<br />2 1/2"
<br />0. 120'
<br />PNEUMATIC
<br />SCREW-NAJLS
<br />1. NAIL SIZE PER ASTM F1684
<br />2. INTERNATIONAL STAPE, NAIL&TOOL
<br />ASSOCIATION (ISANTA) ESR-1539
<br />EMC77RIOR SHE.A7NMG
<br />USE 1/2" COX OR 7/16" O.S.B. PLY WITH Bd RING
<br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES
<br />AND ed RING SHANK GUN NAILS 4" O.C. TOP &
<br />BOTTOM PANEL AND 8d RING SHANK GUN
<br />NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS
<br />OR 7116" ZIP SHEATHING SYSTEM (INSTALLED
<br />PER MANUR SPECS.) SEE DETAIL
<br />8d RING SHANK GUN NAILS 0 4" O.C.
<br />„ TOP & BOTTOM EDGES ,.
<br />aW.
<br />Y Z
<br />N O
<br />°
<br />Y
<br />Z
<br />z
<br />3
<br />n N
<br />o
<br />So
<br />TOP CORD BLOCKING AT 4'
<br />O.C. MAX. IN FIRST 2 FRAMING
<br />SPACES AT EACH END.
<br />RAFTER OR TRUSS -_
<br />ROOF SHEATHING LAYOUT
<br />AND ENDWALL BRACING
<br />FOR GABLE END FRAMING
<br />N
<br />J
<br />W
<br />z L�
<br />z W 8d RING SHANK GUN NAILS
<br />¢ZG 6" O.C. IN FIELD.`
<br />S U J\
<br />NO
<br />O '
<br />m
<br />TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SHEATHING (0 S.B.
<br />a TO BE STRUCTURAL GRADE
<br />Z
<br />W
<br />$ Lu
<br />W
<br />U 8d RING SHANK GUN NAILS 012'O.C. IN
<br />Q U FIELD or 8d x 2 1/2" SCREW SHANK
<br />O PNEUMATIC SCREW -NAILS (CD 12-0.C�I[J
<br />FIE
<br />w
<br />is FIELD J\
<br />a
<br />TYP. 314" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
<br />GENERAL NOTES:
<br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE WALL BE 3W
<br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
<br />WOOD.
<br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
<br />PROVIDE B%AR ENTRAINED CONCRETE FJP(XS®TO FMTH ORWEHTIHt
<br />NON -REARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF.
<br />ARCHITECTURAL DRAWINGS FOR SLEEVES DEPRESSIONS AND OTHER DETAILS NOT SHORN
<br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBCR 2017, BUI EDITION
<br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFBED 3/4'.
<br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING,
<br />AG 318-14, BUILDING CODE REQUIREMENTS
<br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF
<br />FOR STRUCTURAL CONCRETE, ACI 53G-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF
<br />PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE LNX3NALL SIAB80N43ROUIDWHIMINDICATEDON
<br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
<br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 ANDAISC SPECIFICATIONS
<br />DRAWINGS. SEAMS LAPPED B INCHES AND SFALEDWTTHADIESIVE TAPE
<br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES
<br />SHALL SE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISOCIUM
<br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
<br />FORMWORK:
<br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY
<br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
<br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS,
<br />REASON SWILL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED
<br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WTH AG $47,
<br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT
<br />'RECOMMENDED PRACTICE FOR CONCRETE FORMWORK
<br />CONTAINS MORE THAN W OF HEARTWOOD.
<br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
<br />DRAW NGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
<br />EXCLUSIONS FROM THESE PLANS:
<br />MINIMUM NAILING PER PBOR 2017, ft EDITION. SEE HAILING SCHEDULE ON PLANS.
<br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
<br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
<br />OF THE WORK.
<br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL.DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND MOD COLUMNS WITH 2x STRUCTURAL LUMBER
<br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS
<br />SYP #2.
<br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
<br />IS COMPLETE. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
<br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
<br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
<br />TEMPORARY BRACING, GUYS OR TIE-0OWMS.
<br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
<br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
<br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
<br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />DESIGN LOADS:
<br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 Far
<br />20 cP TOP CHORD t
<br />WELDED WIRE MESH:
<br />WELDED W RE MESH, SHALL BE ASTM A185, GRACE 85 AND BE PLACED IN ACCORDANCE WTH THE ACI
<br />TYPICAL DETAILS. MI MMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. W RE MESH FOR SLABS SHALL BE
<br />SUPPORTED WITH 2' CHAIRS SPACED T-0- OC, EACH WAY.
<br />REINFORCING STEEL:
<br />REBAR SHALL BE ASTM AS15 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN
<br />ACCORDANCE W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND
<br />SPEGFlCATIDNS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO
<br />FABRICATION, HORIZONTAL AND VERTICAL BARS SHALL LAP 8 x BAR NO. UNSCHEDULED FIELD LAPS ARE
<br />SUBJECT TO ENGINEER'S REVIEW.
<br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 26' 08 BAR - 36"
<br />p nonconcurran #5 BAR - 30' #7 BAR - 42"
<br />10 p4f BTM CHORD no -current PROVIDE 30' x 38' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS
<br />DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION.
<br />15 pef TOP CHORD 20 pef TOP CHORD
<br />(7 per Wl ASPHALT SHINGLES) (10 pef W/ No GYPORETE)
<br />10 pef STM CHORD 5 pef BTM CHORD
<br />DEAD LOAD TO RESIST W NO UPLIFT: 1 Oper
<br />BALCONY LI VE LOAD 80 paf
<br />STAIRS LIVE LOAD 40 Pef
<br />WIND: DEAD LOAD SPEED =750 MPH 3- SECOND GUST
<br />(ASCE 7-10 (FBC R2017) EXPOSURE B, RISK CATEGORY II)
<br />SHOP DRAWING REVIEW:
<br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
<br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
<br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC
<br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO
<br />THE ARCHITECT. DRAWINGS SUBMITTED WITHOUT REVIEW WLL BE RETURNED UNCHECKED.
<br />SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON-
<br />TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSION FROM
<br />THE ENGINEER.
<br />IN ALL INSTANCES, THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWNGS
<br />CHECKED, UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ARCHITECT.
<br />FOUNDATIOW SITE PREPARATION:
<br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 per,FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY
<br />OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN
<br />ACCORDANCE WTH ASTM D-1557. TREAT ALL SOIL FOR TERMITE PROTECTION.
<br />THE OWWER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER
<br />TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS
<br />FAILING TO MEET THE GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RECOMPACTEDAND
<br />RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN
<br />CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION
<br />REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER
<br />CONCRETE:
<br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS:
<br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE
<br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERIME SLAB
<br />CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS NTH HISTORICAL STRENGTH DATA
<br />FOR EACH SEPARATE MIX PROR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL
<br />NOT EXCEED 5' H- PROR TO THE ADDITION OF PLASTICIZER
<br />CONCRETE SHALL COMPLY WITH ALL THE REQUIRBABNTS OF ACI 301 AND ASTMC-04 OR
<br />MEASURING, MIXING, TRAASPORTING, ETC. CONCRETE TICKETS SHALL BE TIMESTMIPSD
<br />WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED
<br />TO THE MIX UNTIL R IS DEPOSITED IN ITS FINAL POSITION SHALL NOT SOAR 90 MINUTES.
<br />IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS FELD FOR LONGERTWN
<br />90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE TIE RESPONSIBILITY OF
<br />THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE NTH THE
<br />ABOVE
<br />REQUIRED CONCRETE COVERAGE OVER FEW BE AS FOLLOWS
<br />A 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EFOSED TO EARTH(FOl1IDNTDNIS)
<br />B FOR CONCRETE EXPOSED TO EARTH AN!"WEATHER,
<br />I-I/2" FOR 05 AND MVLM
<br />2" FOR #S AND LARGER
<br />C. FOR CONCRETE NOT EXPOSEDTOWEATHBN
<br />314" FOR SLABS, WALLS ID JOIST AS
<br />1.1/2' FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES STIRRUPS
<br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SWILL BE PROVIDED
<br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES.
<br />WOOD TRUSSES:
<br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR
<br />STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
<br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.038" AND BE MANUFACTURED FROM STEEL
<br />MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT-0IPPEDGALVANZED.
<br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL
<br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND 'TPIANTCA BCSI i"
<br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED
<br />WOOD TRUSSES.
<br />TRUSS MANUFACTURER W LL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF
<br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS RED UIRIW ADDITIONAL ROOF FRAMING FOR
<br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982.
<br />ALL VERTICAL REINFORCING BARS IN C M U CELLS SHALL BE ANCHORED IN THE FOOTING,
<br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
<br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
<br />WALL.
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAW NGS FOR ALTERNATE CONNECTION DETAILS AT
<br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL.
<br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS, DOWEL
<br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE.
<br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING
<br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
<br />DO NOT OUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
<br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
<br />WITHOUT THE APPROVAL OF THE ENGINEER.
<br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIEDTO THE
<br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
<br />MASONRY:
<br />PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION
<br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE
<br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />"SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 5/rMS 402, BUILDING CODE REQUIREMENTS FOR
<br />LICENSED PROFESSIONAL ENGINEER.
<br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS
<br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE
<br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE.
<br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
<br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
<br />PROVIDED BY THE TRUSS ENGINEER.
<br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE fm - 1500 PSI. BLOCK SHALL BE PLACED USING
<br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
<br />RUNNING BOND UNLESS OTHERW SE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
<br />OF THE DELEGATED TRUSS ENGINEER. VIAND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT
<br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH
<br />AND CLADDING W NO LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
<br />ASTM C-078, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS
<br />ALL TRUSS TO TRUSS CONNECTIONS.
<br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX $KILL HAVE A MAXIMUM 318"
<br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "USP STRUCTURAL
<br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF W TO 10". USE ONLY MECHANICAL VIBRATION
<br />CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS
<br />TO CONSOLIDATE GROUT.
<br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE
<br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
<br />LATEST CATALOG.
<br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
<br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
<br />CELLS TO BE FILLED.
<br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL
<br />REINFORCING.
<br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O
<br />STRUCTURAL STEEL:
<br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WTH THE
<br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
<br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM
<br />A38, Py • 36 ksi FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM A�500, GRADES,
<br />Fy= 46 kci. STRUCTURAL PIPE SHALL SE ASTM53, GRADE B, TYPE E OR S, Fy = 35 W. TUBE AND PIPE
<br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
<br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL
<br />OTHER BOLTS SHALL BE ASTM A325-N BOLTS WTH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL
<br />BE TIGHTENED IN ACCORDANCE WITH THE TURNOFF -THE -NUT METHOD.
<br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. JAOLTS ARE TO BE STEEL.
<br />FASTENER SCHEDULE
<br />WINDOW AND
<br />DOOR BUCK FASTENERS
<br />FASTENER
<br />APP-TON
<br />STD=
<br />TYPE
<br />SARONG
<br />REMARxS
<br />_LNAIION
<br />.1.
<br />1TYPE
<br />S_NG
<br />REMARKS
<br />I#PTn INGTO
<br />MASONRYICONC
<br />CASE IMROEN.-
<br />NNL I - LONG
<br />B'QC
<br />GARNSE DOOR B'CI(
<br />TO MASONiYIOONG
<br />SEE DE-L
<br />BEE DETNL
<br />SEE DETNL
<br />SEE DETNL
<br />�, IXT DOOORT.E
<br />CASNNLttm
<br />WR1�4MWOM ®
<br />TOMAEOEICCiROYI_
<br />SEE DETNL
<br />SEE DETNL
<br />SEE DETNL
<br />SEE OETNL
<br />S�
<br />0®NCGCLL
<br />3TAOG�ED
<br />CASNu1LM11? CM
<br />W.-
<br />smTa ro
<br />CONTACT THIS ENGINEER
<br />FOR SPACING
<br />1a M.CCBEENDIEB
<br />sT fAED
<br />MO MABOCRIAI_ENEO
<br />ME�rAN
<br />REQUIREMENTS
<br />EM. SMNO DOOR
<br />(2).-
<br />"TA-
<br />1S"OC
<br />11. EMBED.CEBO
<br />NON.BFARING WOOD
<br />E
<br />11 %PM151pN d'EMSED. d'FMl
<br />1d'DO
<br />BUCK 3v PT. SEENOIEe
<br />NO WASTER
<br />FASTNFA
<br />DI$T.,112'EOOEDSr.
<br />-1IO LONG eLAB
<br />W/WASHER Ba.T OIST.,S'EDDEa
<br />h Pr WINDOW BRIG( B.1BB°PAFv]1N' e'00 d-ENp�. asi tt?
<br />PTTOSTEEL COL..6EE W/WA9iBt STAOGEREO
<br />NOTES
<br />11�LE8 SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
<br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL SE AS PER MANUFACTURERS SPECS AND / OR NOA
<br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
<br />4. PAF SHALL BE HILTI XZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
<br />5. FASTENER SPACING FOR THE SUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE
<br />8. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. lx MEMBERS ARE NAILED AND
<br />2x MEMBERS ARE SECURED W/TAPCONS OR PAP TO THE SUBSTRATE.
<br />Am I
<br />IV
<br />s
<br />1441 N. RONALD REALM BLVD.
<br />LONGWOOD, FL 32750
<br />PH: 407-7748078
<br />FAX:407-7744078
<br />www.abdosigngroup.com
<br />AA #: 0003325
<br />8
<br />ra
<br />O
<br />14
<br />Q
<br />ounDIv. a L02:
<br />SILVERADO
<br />LOT #12
<br />BLK #7
<br />PROJWTIP
<br />04 .002-120 1
<br />MODRU
<br />4EBB
<br />"1828-CALI"
<br />GAVAOa 9WINO:
<br />RIGHT
<br />PACE
<br />DETAILS
<br />150 MPH EXP. H
<br />-)f : _ .'�
<br />pumT
<br />DATO01/18/19
<br />smax: 1/4"=1'-0"
<br />s ITT 1