HVAC NOTES <br />I. ALL MECHANICAL EGUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS $BALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB i MASTIC. AND <br />INSTALLED A8 PER POO 6TH EDITION (2011) MECHANICAL BLDG, CODE SECTION 603, <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-31 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATPOF918 SHALL BE CONSTRUCTED IN ACCORDANCE TO PBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES 814ALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL NAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />Mi ALL FIRE RATED CEILINGS AND WALLS ALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS $HALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DW BOOSTER PAN OR EQUAL. <br />PANTEC 4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUINK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />(SI <br />PASS-THRU AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />SECURE STRAP TO CONC. CONDENSER <br />PLENUM <br />T y <br />AIR RETURN <br />W/ 12J-3/Ib'X2' TAPCONS WIT SIMF801V WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />AIR HANDLER <br />y <br />SECURE STRAP TO WIT W/ (2) <br />4' CONCRETE SLAB 40XI 1/4' SHT. MTL. SCREWS <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING WIT <br />NOTE: MAIN C XJD. DRAIN 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE OVER HEAD • 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION N"2.4 <br />HVAC <br />DRAINS <br />8CORIATED NICKEL FIN. FLOOR C G.O <br />. PLUG <br />BRONZE FL. PL. OR WALL <br />SEE SPEC. <br />co <br />i'-8 X8' CONC. <br />BRA" PLUG FIN, GRADE <br />OR PAVING <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS FITTING OR <br />REQUIRED EXTENSION TO SOIL <br />OR WASTE AS <br />WADE 8240-K JOSAM 560M REQUIRED <br />INSIDE SERIES NICKEL ORA" TOP <br />CAULK P.VG OPTI/BPEC <br />INV. <br />SITE PLAN gl <br />FLOOR SLAB CLEAN -OUT (T ? EXT. GROUND CLEAN -OUT (TY <br />mo <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32780 <br />PH: 407-7744078 <br />FAX: 407-774.4078 <br />www.abdoWSWoup.com <br />AA is 000332E <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />543E BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 81348862828 <br />FAX: 813.8862802 <br />sunDly as Lo'r. <br />SILVERADO <br />LOT #1 <br />BLK TgrlA <br />PRo"=T* <br />03719.000-01141 <br />MODZIa <br />2795—CAMDEN <br />GARAGE EKING: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />II <br />W <br />ATE: 06/11/20 <br />sCALN 1/4"=l'-0" <br />MECHANICAL PLAN <br />SCALE: 1/4 • I'-0' <br />M1 <br />