Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHMG OVER <br />TOP, SIDES) AND BOTTOM <br />PLANWS OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE O, PLASHING TO ISE, <br />1. BOTTOM. 2. SIDE&. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO EYE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY PROM JOINTS. <br />E-Z DEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE&YW CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Eeftft INhltw and PW6II hV <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WPM LAYER 01, <br />i <br />STUCCO WRAP <br />cl <br />... HOODED VENT <br />il' THICK, 3 COAT O79ENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 42, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />SHEATHING <br />WFB LAYER 02, FONITIFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />S' CMU VINYL CASING OEAD <br />6' RAISED BAND <br />K' TO K' MID -WALL <br />n <br />6' WIDE STRIP SELF <br />ADHESIVE PLASNNING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z PLASHING <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'OUIOC <br />FLASH' <br />PIPE THROUGH — <br />WALL <br />6' SELF ADI4ES11A <br />FLASHING (INSTAL <br />PER MANUR SPEC <br />BUILDING PAPER <br />UNDER 'QUICK FLA <br />(A )VENT PENETRATION <br />SCALE, N.T.S. <br />I ELEC. METER FIELD <br />STONE VENEER VERIFY LOCATION ELEC. METER FIELD <br />OVER SCRATCH COAT VERIFY LOCATION <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCKI <br />LEGEND <br />DRAINAGE PLANE (LURE <br />LAYER 01, STUCCO LURAP) <br />LURE LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN. 2.5 LBS. <br />PER $0. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />Ys' TO Ya' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />-PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />U.RB LATER h, <br />STUCCO WRAP <br />WOOD SHEATHIU <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH T14A <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAc <br />ED(xE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHM6 <br />Wo:6 LAYER 01, <br />STUCCO WRAP <br />WRB LAYER V, PORTIFIDER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD 6TRJCTJRAL <br />MEMBER • T O.G. MAX <br />36' TO & MID -WALL <br />WFAE SCREED <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />8' <br />WRB LAYER N, <br />STUCCO WRAP <br />CUT -A' INTO <br />SELF -ADHERING <br />4 <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />STEP #1 <br />5TEP 02 <br />777t_� <br />Ulm LAYER h, <br />STUCCO WRAP <br />APPLY 60 MIN — <br />GRADE 'D' FELT <br />OVER <br />SELF-AD14ERNG <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />5TEP #3 <br />® { SELF <br />MBRANEILASHING <br />WRB LAYER s2, FORTIFIBER <br />BUILDING PAPER <br />STEP :04 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />5TEP #5 STEP #ro <br />@)ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO,FL32750 <br />PH: 407-7748078 <br />FAX 407-7744078 <br />www.abdosigngroup•com <br />AA ff: 0003326 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813486-2628 <br />lIkk FAT(: 8134MG-2802 Al <br />A(� <br />sss� <br />r <br />UNDLV. & LOT:SILVERAD0LOT #2 <br />BLK 13 <br />PROJMCT# <br />03719.000-02131 <br />MCDZU <br />2795-F <br />OARAOZ EIQMC: <br />EFT <br />PAOR: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH E . B <br />E' <br />R <br />6/11/20 <br />1/4"=1'-0"A2 <br />