HVAC NOTES <br />■ <br />1. ALL MECHANICAL EQUIPMENT SHALL8,HALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALT. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATINGG, ALL SEAMS SHALL BE SEALED WITH GLASS FAIS 4 MASTIC. AND <br />INSTALLED AS PER POO 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL PLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH aei V. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO PBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO ISE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND POO 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />PANTEC 4 DBF IIO DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE. RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST PAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />N <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />SECURE STRAP TO CONG. <br />CEILING <br />EXTERIOR WALL <br />W/ (2)-3/I6'X2' TAPCONS <br />UNIT <br />SIMPSON WB ROLL STRAP <br />O <br />O <br />OR EQUAL <br />PLENUM <br />y <br />AIR RETURN <br />AIR SUPPLY <br />y <br />RUCTION AND LIQUID <br />REFRIGERANT LINES <br />4.�� �� SECURE STRAP t0 UNIT W/ (2) <br />fSXI V4' SHT. MTL. SCREWS <br />AIR HANDLER <br />y <br />CONDENSER UNIT <br />EXTERIOR WALL <br />y <br />9/4' PVC CONDENSATE DRAIN LINE <br />CONNECTION TO PAD <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />T <br />REFRIGERANT LINES TO <br />OVER HEAD • 12' FROM STRICTURE <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />COINTERBU K <br />Co. PLUG <br />6' <br />BRA66 PLUG <br />-�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />///--- WADE 8240-K JOSAM 56000 <br />INSIDE / SERIES NICKEL BRASS TOP <br />CAULK / P.V.0 OPTVSPEC <br />vFL00R SLAB CLEAN -OUT (T <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'XB' CONC. <br />PITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />nEXT. GROUND CLEAN -OUT (TYP. <br />MECHANICAL PLAN <br />SCALE. 1/4 . P-0' <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO,FL32750 <br />PH: 407-7746078 <br />FAX 407-7744078 <br />www.abdosigngroup.com <br />AA M: 0003325 <br />IF DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813888.2H28 <br />FAX: 813888.2802 <br />91111111113 <br />sxnwm ae Lo; <br />SILVERADO <br />LOT #2 <br />BLR #13 <br />PROJECT# <br />03719.000-02131 <br />MODEU <br />2795- F <br />GARAGE 8111MG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />