Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />MRS LAYER 1, <br />STUCCO WRAP <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, BIOE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SE611ENCE OF R_ABHINfi TO BE, <br />L BOTTOM. 2. BIDES. 3. TOP <br />VENT CAP IS TO DE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IB TO BE <br />TOOLED 60 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,Y4 CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Efderlor WINne and DlaaNrby <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />k THICK, 3 GOAT CEMENT <br />PLASTER <br />METAL LATH <br />WRS LAYER 4, FORrIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />BNEATHNG <br />WRB LAYER 4, FORTIFIBER <br />ISUILDNG PAPER <br />WOOD — <br />CONSTIICTION <br />—FETAL LATH <br />a' Cm VINYL C:A6NG BEAD <br />V RAISED BAND <br />. `. 8' To Jr No ulA- LL <br />6' WIDE STRIP SELF <br />ADHESIVE PLA814NG, CLEAN <br />MASOMIY BEFORE APPLYING <br />Z PLAA614NO <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—X—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-1031.1 / ASTM C-84i-OS, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />&' SELF ADHESIVE — <br />PLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE, NT.S. <br />ELEC. METEF <br />VERIFY LO <br />fi1iCA4 IV ICGtiGIYC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 1, <br />STUCCO WRAP <br />WRB LAYER 112, FORTIF15ER <br />BUILDING PAPER <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />Ye' TO Ya' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (I) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />17 BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LATER 1, <br />STUCCO WRAP <br />WOOD SNEATHIf <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAA <br />EDGE <br />APPLY E-Z <br />OVER b® MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />STEP #3 <br />WOOD 814EAT14M <br />LAYER 1, <br />STUCCO LLRAP <br />LAYER •2, FORiIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD <br />C"TRJCTf <br />TEXTURED <br />✓—FINISH a WOOD <br />FASTEN TO WOOD 6TRJCTURAL <br />MEMBER a ''Or— MAX <br />o' CMU <br />7i• TO K' MID -WALL <br />gCEP ar,�r'� <br />6' WIDE STRIP SELF <br />ADHESIVE PLAS64M GLEAN <br />MASONRY BEFORE APPLYING <br />TEXTURED <br />FINISH a MAGCI W <br />HORIZONTAL WEEP SCREED <br />(FRAME <br />TO BLOCK( <br />S' <br />WRB LAYER 1, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />1 <br />STEP #2 <br />WRB LAYER 1, <br />STUCCO WRAP <br />CwRAAPPLY D' MIN ® —SELF-ADHERING <br />GRADE 'D' FELT MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />It LAYER s2, FORTIRBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />ti METAL LATH <br />STEP 05 STEF No <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774807E <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA M: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />543E BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 819888.2628 <br />FAX: 813888.2802 <br />aUDDIV. k LOT: <br />SILVERADO <br />LOT #3 <br />BLK, 14 <br />PROJECT# <br />0371 .0 0-03141 <br />MODEIA <br />2795-B <br />GARAGE 8WWO: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />