Laserfiche WebLink
GIStE-END �+�' <br />HIP RODE <br />ROOF WIND DESIGN PRESSURES <br />NET ZONE 1 O ) . 8.97 PSF (19.97) <br />ZONE 2 =17.98 PSF (27.98) <br />ZONE 3 = 33.53 PSF (43.53) <br />"A"- 4'-0" END ZONE DISTANCE <br />BASIC WIND SPEED: 150 MPH <br />WAND EXPOSURE: "B" <br />RISK CATAGORY: II <br />APPLICABLE INTERNAL <br />PRESSURE COEFFICIENT H 0.18 <br />"ROOF DNPINAW <br />FOR ASPHALT SHINGLE ROOF, USE MIN 7/10' <br />"O.S.B. OR 1/7, CDX EXT. PLYWOOD, FOR <br />-CEMENTITIOUS TILE AND METAL ROOFING, USE <br />MIN. 5/8 CDX EXT. PLYWOOD. WITH 8d RING <br />.SHANK GUN NAILS AT 4" O.C. AT SUPPORTED <br />PANEL EDGES AND Sol RING SHANK GUN NAILS <br />AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE <br />DETAIL <br />ROOF SHEATHING TO GABLE END FRAME USE <br />Bd GUN NAILS 0 4" O.C. EDGEWISE N4 <br />BLOCKING ALL PANEL JOINTS VW IN 4' OF GABLE <br />END, <br />ROOF/ WALU FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />NAIL SCHEDULE <br />SIZE <br />TYPE <br />MIN. LENGTH <br />MIN. DIA. <br />SHANK <br />TENSILE STR. <br />SHANK <br />Sd <br />RING SHANK <br />2 12" <br />0.120" <br />170,000 <br />RING <br />SCREW SHANK <br />(16-20 RINGS <br />PER INCH) <br />8d <br />SCREW SHANK <br />2 tl2' <br />0. 120' <br />PNEUMATIC <br />SCREW -NAILS <br />1. NAIL SIZE PER ASTM F1864 <br />2. INTERNATIONAL STAFF, NAIL & TOOL <br />ASSOCIATION (ISANTA) ESR-1539 <br />EXTERIOR SHEATHBBG <br />USE 1/2" CDX OR 7/18" 0.8.8. PLY WTH 8d RING <br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES <br />AND 8d RING SHANK GUN NAILS 4" O.C. TOP & <br />BOTTOM PANEL AND Ed RING SHANK GUN <br />NAILS AT 8' O.C. AT INTERMEDIATE SUPPORTS <br />OR 7/18" ZIP SHEATHING SYSTEM (INSTALLED <br />PER MANUF. SPECS.) SEE DETAIL <br />8d RING SHANK GUN NAILS (M 4" O.C. <br />TOP &BOTTOM EDGES „ <br />W. <br />Y Z <br />U <br />J <br />O <br />z <br />z <br />O <br />aZ <br />N ' <br />TOP CORD BLOCKING AT 4' <br />O.C. MAX. IN FIRST 2 FRAMING <br />SPACER AT EACH END <br />RAFTER OR TRUSS <br />EMMMIN - I I <br />ROOF SHEATHING LAYOUT <br />AND ENDWALL DBRACING <br />FOR GABLE ENfRAABNO <br />8d RING SHANK GUN NAILS <br />ffi6"O.C. INFIELD.` <br />TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SHEATHING (0 S.B. <br />TO BE STRUCTURAL GRADE <br />CBd RING SHANK GUN NAILS a 12" O.C. IN <br />FIELD or 8d x 2 1/Z'SCREWSHANK <br />PNEUMATIC SCREW -NAILS a 17 0..0 <br />• FIELD J\ <br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />GENERAL NOTES: <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE 31C. <br />STRUCTURAL DRAWINGS SHALL BE USED IN 00NIUNCTION MATH JOB SPEC FICATTONS AND <br />: <br />Wow:PROVIDE <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT <br />B%AIR ENTRAINED CONCREfEBO'09®TO EARDIORNEATHER <br />NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. <br />ARCHITECTURAL DRAW NGS FOR SLEEVES DEPRESSIONS AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2017, 881 EDITION <br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CFALFER67314'. <br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />AG 318-14, BUILDING CODE REQUIREMENTS <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO.2 OR BETTER. FID - 1100 PSI AND A MODULUS OF <br />FOR STRUCTURAL CONCRETE, ACI ANSI SPECIFICATION FOR THE DESIGN Of <br />PROVIDE 84A11 CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE IYgBNM1 SlABSONGR0UNI1 WN87E INDICATED <br />ELASTICITY = PSI. ALL HOOD IN CONTACT WITH CONCRETE OR CONCRETEOFOR BLOCK SHALL <br />MEMBERS 0113 <br />COLDFORMED STEEL STRUCTURAL MEMBERS ASCE 7-10 ANDAI3C SPECIFICATIONS <br />TIONS <br />DRAWINGS. SEAMS LAPPED eINCHES AND SEAL®NBRiA01f91YETPPE <br />EARED, <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED, WOOD FOR NON-STRUCTURAL USES <br />A <br />SHALL BE RATEDTO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: GSODIUM <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />FORMWORK <br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />L CONSTRUED TO APPLY I <br />SEAL BE C TRUED LY TO ANY 9 SITUATION ELSEWHERE ON THE PROJECT, <br />FORM -WORK SHORING AND BRACING FOR ALL CONCRETE BEAMS LA COLUMNS, WA <br />SLABS, LU LL9, <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WTH AG 347, <br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT <br />'RECOMMENDED PRACTICE FOR CONCRETE FORM4VORK. <br />CONTAINS MORE THAN X"OF HEARTWOOD. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT <br />EXCLUSIONS FROM THESE PLANS: <br />MINIMUM NAILING PER FBOR 2017, Bth EDITION. SEE NAILING SCHEDULE ON PLANS. <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />OF THE WORK. <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTUARALDEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS <br />SYP 02. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIECOWNS. <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR <br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. <br />DESION LOADS: <br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf <br />20 psf TOP CHORD --owc-nt <br />10 psf BIM CHORD t wo concunnt <br />DEADLOAD DEAD LOAD <br />15 psf TOP CHORD 20 Psf TOP CHORD <br />(7 pef W/ ASPHALT SHINGLES) (10 psf W/ No GYPCRETE) <br />10 psf BTM CHORD 5 psf 8TM CHORD <br />DEAD LOAD TO RESIST WIND UPLIFT: IOpsf <br />BALCONY LIVE LOAD 60 pef <br />STAIRS LIVE LOAD 40 pef <br />WIND: DEAD LOAD SPEED=150 MPH 3-SECOND GUST <br />(ASCE 7-10 (FBC R2017) EXPOSURE B, RISK CATEGORY II) <br />SHOP DRAWING REVIEW: <br />SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTItt, LENGTH, ELEVATIONS, DIMENSIONS, ETC <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO <br />THE ARCHITECT. DRAWINGS SUBMITTED WITHOUT REVIEW W LL BE RETURNED UNCHECKED. <br />SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON- <br />TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSION FROM <br />THE ENGINEER. <br />IN ALL INSTANCES, THE CONTRACT DOCUMENTS W LL GOVERN OVER THE SHOP DRAWINGS <br />CHECKED UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ARCHITECT. <br />FOUNDATION SITE PREPARATION: <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 pef, <br />FOOTING EXCAVATIONS AND SLAB SUB�GRADE SHALL BE COMPACTED TO A DRY DENSITY <br />OF AT LEAST 95%OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN <br />ACCORDANCE WITH ASTM 0-1557. TREAT ALL SOIL FOR TERMITE PROTECTION. <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER <br />TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS <br />FAILING TO MEET THE GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND <br />RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT, WRITTEN <br />CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION <br />REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER. <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS <br />2,500 PSI REGULAR MIGHT FOR FOOTINGS, AND SLAB -ON -GRADE <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5- STRUCTURALTERIME SLAB <br />CONTRACTOR SHALL SUBMIT PROPOSED MX DESIGNS, WITH HISTORICAL STRENGTH DATA <br />FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL <br />NOT EXCEED S 41-PRIOR TO THE ADDITION OF PLASTICM <br />CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C44 OR <br />MEASURING. MANG, TRANSPORTING, ETC CONCRETE TICKETS SHALL BE TIMMANFED <br />WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED <br />TO THE M%UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT D0:® 90 MINUTES. <br />IF FOR ANY REASON TIERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN <br />90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHN.L BE THE RESPONSIBILITY OF <br />THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WITH THE <br />ABOVE <br />REQUIRED CONCRETE COVERAGE OVER FEW SHALL BE AS FOLLOW. <br />A 3' FOR CONCRETE CAST AGAINST AND PERMANENTLY DEPOSED TO EARTH FOUNDATIONS) <br />B FOR CONCRETE EXPOSED TO EARTH ANOM WEATHER <br />1.10'FOR MI AND SMALLER <br />2" FOR "AND LARGER <br />C. FOR CONCRETE NOT EITORIO TO MATHER <br />314" FOR SLABS WALLS AND JOISTS <br />1-1tT FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES STIRRUPS <br />WELDED WIRE MESH: <br />WELDED WIRE MESH, SHALL BE ASTM A185, GRADE 85 AND BE PLACED IN ACCORDANCE WITH THE AG <br />TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. W RE MESH FOR SLABS SHALL BE <br />SUPPORTED WITH 2' CHAIRS SPACED T-O" OC, EACH WAY. <br />REINFORCING STEEL <br />REBAR SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN <br />ACCORDANCE W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE AG STANDARDS AND <br />SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO <br />FABRICATION. HORIZONTAL AND VERTICAL BARS SHALL LAP 8 x BAR NO. UNSCHEDULED FIELD LAPS ARE <br />SUBJECT TO ENGINEER'S REVIEW. <br />TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" <br />#5 BAR - 30' #7 BAR - 47' <br />PROVIDE 36'. 36' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR SEE DETAILS <br />FOR ADDITIONAL INFORMATION. <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALLAT THE TOP AND BOTTOM WITH <br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES. <br />WOOD TRUSSES: <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE WATIONAL DESIGN SPECIFICATIONS FOR <br />STRESS -GRADE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNEDAND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.038' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A448, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14,'DESIGN NATIONAL <br />STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND 'TPINJTCA SCSI 1" <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOVER ROOFS IN ACCORDANCE WTH ANSI A58A-1982. <br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS, <br />WALL. <br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES ANDAROUND CORNERS. DOWEL <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. <br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FORBEARING <br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />WITHOUT THE APPROVAL OF THE ENGINEER. <br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />MASONRY: <br />PROVIDE ENGINEERED SHOP DRAW NGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WTH ALL REQUIREMENTS OF THE <br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />"SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 5rrMS 402, BUILDING CODE REQUIREMENTS FOR <br />LICENSED PROFESSIONAL ENGINEER, <br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE <br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />ALL BLOCK WALLS SHALL BE TVJDCELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />PROVIDED BY THE TRUSS ENGINEER <br />MANUFACTURED IN CONFORMANCE WITH ASTM CIO, GRADE f m - 1500 PSI. BLOCK SHALL BE PLACED USING <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE <br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF 71E BEAMS BEFORE <br />OF THE DELEGATED TRUSS ENGINEER, W ND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT <br />PLACING CONCRETE FOR INWALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH <br />AND CLADDING W LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR <br />ASTM C476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />S <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 318" <br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "USP STRUCTURAL <br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF 8" TO 10'. USE ONLY MECHANICAL VIBRATION <br />CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS <br />TO CONSOLIDATE GROUT. <br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE <br />TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />LATEST CATALOG. <br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />CELLS TO BE FILLED. <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANDIOR VERTICAL <br />REINFORCING. <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O <br />STRUCTURALSTEEL- <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WTH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FORBUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION STRUCTURAL STEEL SHALL BE ASTM <br />A38, Fy - 36 ksi FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B, <br />Fy = 46 ka. STRUCTURAL PIPE SHALL BE ASTM53, GRADE B, TYPE E OR S, Fy = 35 kw. TUBE AND PIPE <br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL <br />OTHER BOLTS SHALL BE ASTM A325-N BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL <br />BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. <br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK FASTENERS <br />FASTENER <br />APPLIGTON <br />81. <br />TYPE <br />SPA.. <br />REM . <br />APPUGTON <br />813E <br />TYPE <br />.-No <br />IPEMPAx4 <br />1xl PTWRRINGTO <br />MABCNRYI CONC <br />GABS HARDBIEDCOIL <br />NNLI I?LONG. <br />A QC <br />GARAGEDDORBI.IiI <br />TO MABCWiVINNC. <br />eEE DETNL <br />SEE DETNL <br />BEE DETNL <br />SEE DETNL <br />e00pN.. ExT.OW b <br />1 T, SEEN03E8 <br />CASE-B'O.0 <br />NNLII LONG, <br />STAGGERED <br />WNDO4MDOIXL FASIEI® <br />INTO MA80N3YICONC <br />GNLUEOOd39.A]( <br />TO MASONH- <br />SEE DETNL <br />SEE DETAIL <br />BEE DETNL <br />SEE DETNL <br />WINDOW Rx <br />CASE NeROENED_ <br />B'oA; <br />wwooVw000a FASTBIEO <br />METALSTRAPTo <br />CONTACT THIS ENGINEER <br />FOR SPACING <br />1. PT. SE-6 <br />NNLI IYPLOAD. <br />STAGGERED <br />INTOMAS0M2YICONC <br />MASONM/C <br />REQUIREMENTS <br />Efq. SWxIGWOR <br />(1)308'DN <br />TAPttxf <br />1B, O.0 <br />1t.-aeo,- <br />NON_S__NOOD <br />12° EXPANSION 21= a'EMBED. PED <br />BUCx3XPT, SEENDTEB <br />NOWA4HBi <br />FABTFfii <br />1112'�GEget <br />WALL TO CONIC. BlN3 <br />WI WASHER BOLT DIST, 3•EOGEgBl. <br />�P!`Aw00W BUCK 0.138°PAFa31.8' B'OIC END. MET, <br />0STEEL C0...8ff W/WASHER eTAGG-ED 4- EDGE 018f7 <br />NOTES <br />11. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECSANDIOR NOA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED. HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE <br />S. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. 1. MEMBERS ARE NAILED AND <br />2x MEMBERS ARE SECURED W/TAPCONS OR RAF TO THE SUBSTRATE. <br />alp <br />• <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX:407.774.4078 <br />www.abdesWngroup.com <br />AA #: 0003325 <br />>: <br />j <br />aY3yT <br />Edli <br />9 <br />w <br />i <br />m <br />O <br />9 <br />�o <br />i <br />swan►. as Lam <br />SILVERADO <br />LOT #60 <br />BLK. #6 <br />PROJMTIP <br />41 - 0061 <br />4EBB <br />"1828-CALL" <br />GAPLAGM BVFDM <br />LEFT <br />PAaIM <br />DETAILS <br />%150 MPH EXP. B <br />5 <br />L AR NO 93723 J <br />ATA I <br />sCA7,M 1/SN <br />L <br />