My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7035 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7035 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:29:10 PM
Creation date
2/19/2025 11:38:14 AM
Metadata
Fields
Template:
Building Plans
Street #
7035
Location
Silverado Ranch Blvd
Contractor
DR Horton
Building Plans - Permit #
21665
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICNG, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAIS 4 MASTIC. AND <br />INSTALLED AS PER MC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL I81 CLASS I AIR DUCT AS PER NPPA SCA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(201T) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO ECUAL AIR EXHAUSTED. <br />S ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILNG OR WALL PENETRATION AND 15E SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS, AND PBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WATH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DEF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR OdRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />0 <br />CEILNG EXHAUST FAN <br />CEILING EXHAUST FAN A LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />i9 <br />PASS-THRU AIR GRILL <br />NOTE. <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONIC. <br />CONDENSER <br />ATTIC <br />W/ (2)-3A(s'X2' TAPCONS <br />UNIT <br />SIMPSON WD ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />4'CONCRETE SLAD %XI 1/4'SHT. MTL. SCREWSSUCTION <br />AND LIQUID <br />AIR SUPPLYy <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLERy <br />I <br />CONNECTION TO PAD <br />EXTERIOR W4LL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE. MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD n' FROM STRUCTURE <br />EVAP. TRAYy <br />PVC SLEEVE TO LIDS BELOW SLAB <br />T <br />REPIRIdERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />F5CR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FM. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL C.O. PLUG <br />BRASS PLUG <br />——FITTNG OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.G OPTI/SPEC <br />QFLOOR SLAB CLEAN —OUT ( YR. <br />FN.GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN —OUT (TYP <br />Em <br />MECHANICAL PLAN <br />SCALE, 1/4 . P-0' <br />NOTE. <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE P.P.E. ELEVATION. <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774,6078 <br />FAX: 407-7744078 <br />www'abdes4pi&ouµcom <br />AA 8: 0003325 <br />h <br />r <br />0 <br />$8�8� <br />Will <br />aa <br />a <br />all <br />Bumly. a L01'i <br />SILVERADO <br />LOT #60 <br />BLK. #6 <br />F%wJwT/ <br />04 .002-600 1 <br />1 o=u <br />4EBB <br />"1828-CALL" <br />oAVtA0Z OlFW01 <br />LEFT <br />PAC21: <br />MECHANICAL <br />PLAN <br />%150 MPH EXP. B <br />STATE OF R-OFMI <br />4. 11 <br />AMR 907M <br />PSIDIT <br />DATak3/il/19 <br />SICATM 1/4"=1'-0" <br />a3lio'P <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.