x w
<br />GABLE-EI•D
<br />HWROOF F A JF
<br />RWF WIND DESIGN PRESSURES
<br />ET SS ASCE 7-10
<br />ZONE i = 8.97 PSF (19.97)
<br />ZONE 2 = 17.98 PSF (27.98)
<br />ZONE 3 = 33.53 PSF (4353)
<br />"A"= 4'4I" END ZONE DISTANCE
<br />BASIC WIND SPEED: 150 MPH
<br />WIND EXPOSURE: "B"
<br />RISK CATAGORY: II
<br />APPLICABLE INTERNAL
<br />PRESSURE COEFFICIENT 10.18
<br />ROOF DMIPHRAGM
<br />FOR ASPHALT SHINGLE ROOF, USE MIN 7116'
<br />O.S.B. OR 1/2" COX EXT. PLYWOOD, FOR
<br />CfMENTITIOUS TILE AND METAL ROOFING, USE
<br />MIN. 518 COX EXT. PLYWOOD, WTH Sd RING
<br />SHANK GUN NAILS AT 4" O.C. AT SUPPORTED
<br />PANEL EDGES AND 8d RING SHANK GUN NAILS
<br />AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE
<br />DETAIL.
<br />ROOF SHEATHING TO GABLE END FRAME USE
<br />Sd GUN NAILS @ 4" O.C. EDGEWISE 2x4
<br />BLOCKING ALL PANEL JOINTS W IN 4' OF GABLE
<br />END.
<br />ROOF/ WALL/ FLOOR
<br />SHEATHING
<br />FASTENER SCHEDULE
<br />NAIL SCHEDULE
<br />SIZE
<br />TYPE
<br />MIN. LENGTH
<br />MIN. DIA
<br />SHANK
<br />TENSILE STIR.
<br />SHANK
<br />Sd
<br />RING SHANK
<br />212"
<br />0.120"
<br />170,000
<br />RING
<br />SCREW SHANK
<br />(16-20 RINGS
<br />PER INCH)
<br />Sd
<br />SCREW SHANK
<br />2 U7
<br />0.12W
<br />PNEUMATIC
<br />SCREW -NAILS
<br />1. NAIL SIZE PER ASTM F1664
<br />2. INTERNATIONAL STAPE, NAIL & TOOL
<br />ASSOCIATION (ISANTA) ESR-1539
<br />EXTERIOR SNEATNMO
<br />USE 1/2" COX OR 7116" O.S.B. PLY WITH 8d RING
<br />SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES
<br />AND 8d RING SHANK GUN NAILS 4" O.C. TOP &
<br />BOTTOM PANEL AND Bd RING SHANK GUN
<br />NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS
<br />OR7/16" ZIP SHEATHING SYSTEM (INSTALLED
<br />PER MAN UF. SPECS.) SEE DETAIL.
<br />8d RING SHANK GUN NAILS @ 4" O.C.
<br />TOP & BOTTOM EDGES
<br />9�
<br />z W .
<br />Y 2
<br />2
<br />1U
<br />0 O .
<br />0 (c z
<br />Z
<br />Qj
<br />N
<br />2
<br />Ao
<br />TOP CORD BLOCKING AT 4'
<br />O.C. MAX. IN FIRST 2 FRAMING
<br />SPACES AT EACH END.
<br />RAFTER TRUSS
<br />ROOF SHEATHING —�
<br />BUILDING LENGTH I,
<br />ROOF SHEATHING LAYOUT
<br />AND ENDWALL BRACING
<br />POOR GABLE END FRAMNO
<br />8d RING SHANK GUN NAILS
<br />� 6" O.C. IN FIELD'
<br />TYP. EXT. SHEATHING ATTACHMENT FOR ROOF SHEATHING (O S.B.
<br />TO BE STRUCTURAL GRADE
<br />Bd RING SHANK GUN NAILS 0 12" O.C. IN
<br />FIELD or 8d x 2 17SCREW SHANK
<br />PNEUMATIC SCREW -NAILS C 1Z' O.CJLV
<br />FIELD J\
<br />TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TOALL EXPOSED MEMBERS
<br />GENERAL NOTES:
<br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE3W..
<br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTIONWTH JOB SPECIFICATIONSAND
<br />6%AIR ENTRAINED CONCRETE FX(POSEDTO EARTH ORWEATFHt
<br />WOOD.
<br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
<br />pR0IDE
<br />NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF
<br />ARCHITECTURAL DRAW NOS FOR SLEEVES,DEPRESSIONS, AND OTHER DETAILS NOT SHOYNN
<br />qII OF CONCRETE ARE TONECHAAEBim 3/4'.
<br />ON STRUCTURAL DRAWNGS. APPLICABLE BUILDING CODE STANDARDS: FBO-R 2017, Sth EDITION
<br />EXPOS®EDGES
<br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING,
<br />AG 318.14, BUILDING CODE REQUIREMENTS
<br />T
<br />CRIPPLERS, SILLS, ETC., SHALL BE SOUHERN PIPE NO. 2 OR BETTER, Fb =1100 PSI ANDA MODULUS OF
<br />FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR E DESIGN OF
<br />R
<br />-
<br />PROVIDE 6MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE IMDBRALL SABSONGROIFAWHEFEIM1DICAT®ON
<br />ELASTICITY = 1,400,000 P31. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
<br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPEGFlC4TION3
<br />®YN
<br />DRAWINGS. SEAMS LAPPED B INCHES AND SEA.TH ADHESIVE TAPE
<br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES
<br />RATEDL BE UM
<br />PTHATHILLVE
<br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TAND
<br />FORMWORK;
<br />CORROBORA ETETTRAHE RAL(DOT). WOOD FORS RUUCTURALL USE BE TREATED FOR ANY
<br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE OJECT,
<br />ON ON THE FE PROJECT,
<br />FORM -NARK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS,
<br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED
<br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
<br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WTHACI 347,
<br />W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREAEDLUMBER THAT
<br />'RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK
<br />CONTAINS MORE THAN W OF HEARTWOOD.
<br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD,.00 NOT SCALE THE
<br />DRAWN r'S. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
<br />EXCLUSIONS FROM THESE PILMS:
<br />MINIMUM NAILING PER FBR 2017, 81h EDITION. SEE NAILING SCHEDULE ON PLANS.
<br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
<br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
<br />OF THE NARK.
<br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE SRUCTURALOEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER
<br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUTARE BY OTHERS.
<br />SYP #2.
<br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
<br />IS COMPLETE. IT IS RE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
<br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
<br />DURING ERECTION. THIS NARK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
<br />TEMPORARY BRACING, GUYS OR TIE4DOWNS.
<br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
<br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
<br />DO NOT SCALE DRAWNGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
<br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
<br />DESIGN LOADS:
<br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf
<br />20 psf TOP CHORD --oncurrent
<br />10 psf BIM CHORD •non-conwrrent
<br />DEADLOAD DEAD LOAD
<br />15 psf TOP CHORD 20 psf TOP CHORD
<br />(7 psf W/ ASPHALT SHINGLES) (10 PET W/ No GYPRETE)
<br />10 PET BTM CHORD 5 psf BTM CHORD
<br />DEAD LOAD TO RESIST W ND UPLIFT: 10psf
<br />BALCONY LIVE LOAD SO psf
<br />STAIRS LIVE LOAD 40 psf
<br />WIND: DEAD LOAD SPEED -150MPH 3-SECONDGUST
<br />(ASCE 7.10 (FBC R2017) EXPOSURE B, RISK CATEGORY IU
<br />SHOP DRAWING REVIEW:
<br />SHOP DRAWNGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
<br />OF RE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
<br />COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC
<br />ALL SHOP DRAWINGS SMALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO
<br />THE ARCHITECT. DRAWINGS SUBMITTED WITHOUT REVIEW W LL BE RETURNED UNCHECKED.
<br />SHOP DRAWNGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWNGS (CON-
<br />TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS WRITTEN PERMISSION FROM
<br />THE ENGINEER.
<br />IN ALL INSTANCES, THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS
<br />CHECKED, UNLESS OTHERWSE SPECIFIED IN WRITING BY THE ARCHITECT.
<br />FOUNDATIOW SITE PREPARATION:
<br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 pd.
<br />FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY. DENSITY
<br />OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN.
<br />ACCORDANCE WITH ASTM D-1557, TREAT ALL SOIL FOR TERMITE PROTECTION.
<br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER
<br />TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS
<br />FAIUNG TO MEET THE GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RECOMPACTEDAND
<br />RETESTED AT THE CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN
<br />CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION
<br />REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH.. ENGINEER.
<br />CONCRETE:
<br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS:
<br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB-ONtGRADE
<br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB
<br />CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA
<br />FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL
<br />NOT EXCEED T N-PRIOR TO THE ADDITION OF PLASTICIZER.
<br />CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C44OR
<br />MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED
<br />WHEN CONCRETE IS 84TCHED THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED
<br />TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT 1EXCEED90 MINUTES.
<br />IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGS THAN
<br />90 MINUTES THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBILITY OF
<br />THETESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WITH THE
<br />ABOVE
<br />REQUIRED CONCRETE COVERAGE OVER RE&4RSALL SEAS FOLLUM:
<br />A XFOR CONCRETE CAST AGAINST AND PERMANENTLY E)P0.RFD TO EARTH (FOUNDATIONS)
<br />B. FOR CONCRETE EXPOSED TO EARTH
<br />1-1/2" FOR #5 ANDSMAU.ER
<br />2°FOR#6 AND LARGER
<br />C. FOR CONCRETE NOT EXPOSED TOWFATHER
<br />314. FOR SLABS, WALLS AND JOISTS
<br />142. FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES STIRRUPS
<br />WELDED WIRE MESM:
<br />WELDED WIRE MESH, SHALL BE ASTM A185, GRADE 65 AND BE PLACED IN ACCORDANCE WTH THE AG
<br />TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE
<br />SUPPORTED WITH 2" CHAIRS SPACED T-D" OC, EACH WAY.
<br />REINFORCING STEEL:
<br />REBAR $HALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN
<br />ACCORDANCE W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE AG STANDARDS AND
<br />SPECIFICATIONS. CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWNGS FOR REVIEW PRIOR TO
<br />FABRICATION. HORIZONTAL AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE
<br />SUBJECT TO ENGINEER'S REVIEW.
<br />TYR MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36"
<br />#5 BAR - 30" #7 BAR - 42"
<br />PROVIDE 36 x 36 CORNER RNER BARS BOND BEAM ONLY LAPPEDAND TIED TO EACH BEAM REBAR, SEE DETAILS
<br />FOR ADDITIONAL INFORMATION.
<br />ALL VERTICAL REINFORCING BARS IN CM CELLS SHALL BE ANCHORED IN THE FOOTING,
<br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
<br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
<br />WALL.
<br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
<br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE.
<br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED
<br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES.
<br />WOOD TRUSSES:
<br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR
<br />STRESS -GRADE LUMBER AND ITS FASTENINGS" SY THE NFPA. TRUSS DESIGNS SHALL BE SIGNEDAND
<br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
<br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE MANUFACTURED FROM STEEL
<br />MEETING RE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED.
<br />DESIGN, FABRICATE, AND ERECT V4000 TRUSSES IN ACCORDANCE WITH RI-14, "DESIGN NATIONAL
<br />STANDARDS FOR METAL-PLATECONNECTED-WOOD TRUSS CONSTRUCTION: AND '7PINVTCA BCSI 1"
<br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING; INSTALLATION BRACING METAL -PLATE -CONNECTED
<br />WOOD TRUSSES.
<br />TRUSS MANUFACTURER WLL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF
<br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR
<br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WTH ANSI A56.1-1982,
<br />HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT
<br />TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL.
<br />ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USEDAS A GUIDE FOR BEARING
<br />DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
<br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
<br />LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
<br />WITHOUT THE APPROVAL OF THE ENGINEER.
<br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIEDTO THE
<br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
<br />MMONRr::
<br />PROVIDE ENGINEERED SHOP DRAWNGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION
<br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE
<br />PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />LICENSED PROFESSIONAL ENGINEER.
<br />"SPECIFICATION MASONRY STRUCTURES" (ACI 5301 ASCE .5I TMS 402, BUILDING CODE REQUIREMENTS FOR
<br />MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS
<br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE
<br />PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE.
<br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
<br />ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
<br />PROVIDED BY THE TRUSS ENGINEER.
<br />MANUFACTURED IN CONFORMANCE WTH ASTM C 90, GRADE fm = 1500 PSI. BLOCK SHALL BE PLACED USING
<br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
<br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
<br />OF THE DELEGATED TRUSS ENGINEER. VIAND UPLIFT VALUES HAVE BEEN SASEDON ASCE 7-10 COMPONENT
<br />PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH
<br />AND CLADDING WHO LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
<br />ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT28 DAYS, UNLESS
<br />ALL TRUSS TO TRUSS CONNECTIONS.
<br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN, THE GROUT MIX SHALL HAVE A MAXIMUM 3/8"
<br />ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE"USP STRUCTURAL
<br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF W TO I V. USE ONLY MECHANICAL VIBRATION
<br />CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTAL CONNECTIONS
<br />TO CONSOLIDATE GROUT.
<br />WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE
<br />TYPE "M" OR "S•' MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
<br />LATEST CATALOG.
<br />PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
<br />SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
<br />CELLS TO BE FILLED.
<br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL
<br />REINFORCING.
<br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O
<br />STRUCTURALSTEEL
<br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL $HALL COMPLY WITH THE
<br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
<br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM
<br />ASS, Fy - 36 ksi FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM A6DO, GRADE B,
<br />Fy = 46 kEl. STRUCTURAL PIPE SHALL BE ASTMfi3, GRADE B. TYPE E ORS, Fy = 35 kei, TUBE AND PIPE
<br />COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
<br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL
<br />OTHER BOLTS SHALL BE ASTM A325-N BOLTS WTH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL
<br />BE TIGHTENED IN ACCORDANCE WTH THE TURN -OFF -THE -NUT METHOD.
<br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. JSOLTS ARE TO BE STEEL.
<br />FASTENER SCHEDULE
<br />WINDOW AND
<br />DOOR BUCK FASTENERS
<br />FASTENER
<br />AWUGT-
<br />SIZE
<br />ttPE
<br />SPACING
<br />RENARNE
<br />APPLICATION
<br />SIZE
<br />TYPE
<br />SPACING
<br />REMARKS
<br />1W PTRIRRINGN
<br />MASLPJRYICCNC
<br />CASEHARDENEDCGE
<br />NALI IYP LONG.
<br />GRADE DOOR BUG(
<br />TO
<br />SEE OETAL
<br />SEE DETNL
<br />BEE DE-L
<br />SEE DETNL
<br />SOLO A. EXT DOORS
<br />CASE HARDENED COIL
<br />a"OD.
<br />WINDOWIDOORIFASTENm
<br />GRACE DOOR SUCK
<br />SEE DETNL
<br />SEE DE SEE
<br />DETAIL
<br />SEE DETAIL
<br />Ix PT SEEOTES
<br />NALI-LONG,
<br />STAGGERED
<br />INTO MASONRY/�-
<br />TO M48JNRY(C_
<br />WIN--
<br />—EfMRDENEDCOIL
<br />`_
<br />WINOOW/OOOPIFASTENSO
<br />METALSTRAPTG
<br />CONTACT THIS ENGINEER FQR SPACING
<br />Ix PT.SEENOTES
<br />NAL11/YLONG.
<br />BTAOGERED
<br />INTO MA .YIC —
<br />MASONRYICONC
<br />REQUIREMENTS
<br />EXT &WINO DOOR
<br />(2X3n8'IX4
<br />"TAPOON'
<br />18'OO
<br />itIT EMBED E'END.
<br />NON-SEARNG HOOD
<br />1/f' E�RSION d"EMBED PENO
<br />2<dC
<br />TUCK 2x PT. SEENOTEB
<br />NO WASHER
<br />FA&TNER
<br />D9T.,11iZEOGEDRT.
<br />AL TO CGVL. SIAE
<br />WI WASHEA BOLT OIeT, S"EOGEGET.
<br />2x PTWINDOWe1G( 8.138°PAFx 219" I- <"END. OtST.,11/T
<br />PT TO STEEL WLL., SEE WI WABAER STAGGER® EDGE Q3i.
<br />NOTES
<br />II=
<br />1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPUCATIONS
<br />2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND/OR NOA
<br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
<br />4. PAF SHALL BE HILTI X.ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
<br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF RE NOAOR THE SPACING DETAILEDABOVE
<br />6, W NDOW AND DOOR BUCKS SHALL BE AS W DE OR W DER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WTH A WOOD DOOR FRAME. ix MEMBERS ARE NAILEDAND
<br />2X MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE.
<br />OR
<br />1441 N. RONALD REAGAN BLVD.
<br />LONGWOOD, FL32750
<br />PH: 407-774-6078
<br />FAX: 407-774-4078
<br />www.abdesWngroup.com
<br />AA #: 0003325
<br />W
<br />�
<br />~
<br />L4
<br />QQ4
<br />W
<br />3
<br />-
<br />y
<br />C
<br />J
<br />g
<br />q
<br />a
<br />V
<br />IL
<br />`}i
<br />C
<br />�xnmxv. de wm
<br />SILVERADO
<br />LOT #15
<br />BLK #7
<br />pa
<br />0im
<br />04128.001- 5 71
<br />MODEll.e
<br />4ENB
<br />"1751—NEUVILLE"
<br />GARAGE 9WD?G12
<br />LEFT
<br />PAGIQ:
<br />DETAILS
<br />150 MPH EXP. B
<br />rpaurr
<br />3/11/19
<br />8CA7,Z. 1/4-=1'-0"
<br />MINIEW