Laserfiche WebLink
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF-ADHERMG <br />MEMBRANE FLASHING OVER <br />TOP, 6IDE(8) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SE42UENr'E OF FLASHING TO BE, <br />I. BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY, SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE6A CAULKING • JOINT <br />ALL AROLMD <br />PER SECTION R703.7 <br />EXteda lathing and plastering <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 1, <br />STUCCO WRAP <br />I <br />1 ..: <br />.X; <br />HOODED VENT <br />]' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, POWIFI15EM <br />BUILDNG PAPER <br />WOOD SHEATHNG <br />DRYER <br />VENT (FRAME) <br />WOOD SHEATHING <br />WRB LAYER 1, <br />STUCCO WRAP <br />WRB LAYER -2, FORTFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />61 CMU VINYL CASING DEAD <br />6' RAISED BAND <br />'•. ♦'' ''• V T A, no -WALL <br />61 WIDE 6TNP SELF <br />ADHESIVE FLA6104. CLEAN <br />MASONRY BEFORE APPLYMG <br />Z PLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (UJRB <br />LAYER 01, STUCCO WRAP) <br />UJRB LAYER e2 (FORTIFIBER ...... <br />— — <br />BUILDING PAPER) <br />METAL LATH x—X—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-09, MIN, 2.5 LBS. <br />PER $0. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT is <br />TOP 4 SIDES <br />GB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />I <br />6' SELF ADHESIVE— <br />FLAS14W. (INSTALL <br />PER MANUF. SPECSJ <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />OVENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METED <br />VERIFY LO <br />'7=AA I LW ICCC.CI VC <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />—ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER 42, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />NK' TO 7L' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />!'GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LASZGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHR <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAX <br />EDCsE <br />APPLY E-Z <br />OVER 6m MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSEGTIC <br />WOOD / <br />0ON6TRUCTION <br />a' CM <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />WRB LAYER 4, FORTRBER <br />BUILDING PAPER <br />METAL LATH <br />PASTEN TO WOOD STRiOCTURAL <br />MEMBER • 1. O.G MAX <br />x• ro lf' tllQ:l"�' <br />aeEP aCREED <br />AP44MIVE FLAaHMG, CLEAN <br />MASONRY BEFORE APPLYM <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />8' <br />WRB LAYER 1, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />t <br />MEMBRANE PLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />AP PROVED UM LAYER <br />1 <br />STEP 01 <br />STEP #2 <br />i <br />WRIS LAYER 01, <br />STUCCO WRAP <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />WOUSEWRAP <br />STEP #3 <br />vij MEMBRANE FLASHING <br />UIRB LAYER V, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIG <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECT(ON) <br />METAL LATH <br />STEP 05 STEfi #(o <br />OELECTRICAL RECEPTACLE <br />A R C N I T 1 c T• <br />6 <br />Grows <br />1 41 K. KVK/W V KCPI 6LYV. <br />LONGWOOD, FL 32750 <br />PH: 407.7748078 <br />FAX: 407.7744078 <br />www.abdesigngroup.com <br />AA B: 0003325 J <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813-BM2628 <br />FAX: 8134888•2802 <br />IEItMDIV. da LOT <br />SILVERADO <br />LOT #4 <br />BLK 14 <br />PROJECT/t <br />03719.000-04141 <br />MODEL: <br />2795—D <br />GARAGE >!WZNG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />150 MPH EXP. B <br />DATE: 10/30/20 <br />8CA1E: 1/4"=1'-0" <br />BHEET <br />WA2 <br />