My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7054 Steer Blade Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7054 Steer Blade Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:14:50 PM
Creation date
2/19/2025 11:24:40 AM
Metadata
Fields
Template:
Building Plans
Street #
7054
Location
Steer Blade Dr
Contractor
DR Horton
Building Plans - Permit #
1190
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EGUIPMENT $BALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3J <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 Ft FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, $HALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />IL ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED OATH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH POP 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANG W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />M <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />PBCR 6TH EDITION (2011) <br />MECHANICAL 51-Ca CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SC0RIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />—� FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM B6000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />QFLOOR SLAB CLEAN —OUT (TYP.) <br />N <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRLI AIR GRILL <br />■ <br />- - - - - - - - - - - - - - 12x128 <br />I <br />BEDROOM <br />I 1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />12X12 7 r ! I <br />------------ <br />SECURE STRAP TO GONG <br />W/ (2)-31A*'X2' TAPCONB UNIT SIMPSON WB ROLL STRAP <br />MULTI"GEN <br />OR EQUAL <br />BEDROOM <br />8X4 <br />NI-r� <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />NBXI I/4' SHT. MTL. SCREWS <br />I <br />I <br />L� <br />I <br />CONDENSER UNIT <br />IL <br />1 <br />CONNECTION TO PAD <br />----------- <br />loxs '' <br />12x8 <br />NOTE: MAIN COND. DRAIN 3/4' DMA. <br />PT <br />OVER HEAD . 12' FROM STRUCTURE <br />12x8 <br />-------------- <br />4 <br />I <br />I <br />I <br />I <br />M Su <br />I <br />i <br />I <br />I <br />� <br />I <br />I <br />I <br />- <br />- - - - - - J <br />COUNTERSANK <br />CA. PLUG <br />FIN GRADE <br />OR PAVING <br />rRECAJIMED <br />SPEC. <br />8' CONC. <br />NG OR <br />NSION TO 801E <br />ASTE AS <br />nEXT. GROUND CLEAN -OUT (TYPN) <br />m <br />I I <br />L-----J <br />3-CAR GARAGE <br />------------------------ �I <br />12A 2 PI <br />I <br />COVERED <br />LANAI <br />I <br />I <br />CAFE <br />I <br />I <br />I <br />12X12 - - <br />r-------------------� <br />8X12 <br />II <br />I <br />I <br />II <br />II <br />I <br />8" <br />I <br />e <br />e <br />L <br />I <br />I <br />CARAT <br />11 <br />I <br />ROOM <br />1 <br />1 <br />e"I <br />I <br />I <br />I <br />RIPCfB$V <br />I <br />8X12 <br />I- - - - <br />I <br />- - - - ------J <br />8X4------------- <br />i� ],� <br />� <br />L 7® <br />ROOM <br />,OPTII ii <br />Owi,�ii <br />4"RDRYER <br />I � I <br />6X11 <br />OPT. u <br />I <br />I I <br />D. <br />I <br />18X30 Tf_,6,:rFlmt <br />I I <br />L----------J <br />R <br />A II <br />PWDR <br />ROOM <br />BDRML3 <br />Os" 1OX6 <br />r -8X4 — Q <br />I <br />I PO 1 <br />I 4" <br />0 <br />I 1 <br />I <br />I , <br />L_ <br />e� 12x8 <br />MECHANICAL PLAN <br />SCALE: V4 • P-0' <br />ENTRY <br />PORCH <br />BDRM. 2 <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL327E0 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.00m <br />AA 8: 000332E <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />E439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886-2628 <br />FAX: 81"8862802 <br />IN <br />sunDIv. aLOT <br />SILVERADO <br />LOT #13 <br />BLK #13 <br />PR0JMCTN <br />03719,000-13 <br />mopmu <br />2795—F <br />13ARACI <br />LEFT SMA/ING: <br />PACK: <br />MECHANICAL <br />PLAN <br />150 MPH EXP. B <br />